• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.03 seconds

A Study on the Estimating Direct Normal Insolation Using Horizontal Global Insolation for Solar Thermal Generation System Installation in Korea (법선면 직달일사량 예측기법을 이용한 한반도에서의 태양열발전단지 건설을 위한 최적지 선정에 관한 연구)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.77-87
    • /
    • 2012
  • Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. For the validation, estimated direct normal Insolation is compared with observed direct normal Insolation at 16 sites over the Korean peninsular from January 1982 to December 2010. Estimated direct normal Insolation shows reliable results with average deviation of -5.4 to +5.9% from the measured values and the yearly averaged direct normal Insolation of Korean peninsula was turned out to be 2.93 $kW/m^2/day$.

A Study on Probabilistic Reliability Evaluation of Power System Considering Wind Turbine Generators (풍력발전기를 고려한 전력계통의 확률론적인 신뢰도 평가에 관한 연구)

  • Park, Jeong-Je;Wu, Liang;Choi, Jae-Seok;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1491-1499
    • /
    • 2008
  • This paper presents a study on reliability evaluation of a power system considering wind turbine generators (WTG) with multi-state. Renewable energy resources such as wind, wave, solar, micro hydro, tidal and biomass etc. are becoming importance stage by stage because of considering effect of the environment. Wind energy is one of the most successful sources of renewable energy for the production of electrical energy. But, reliability evaluation of generating system with wind energy resources is a complex process. While the wind turbine generators can not modelled as two-state model as like as conventional generators, they should be modelled as multi-state model due to wind speed random variation. The methodology for obtaining reliability evaluation index of wind turbine generators is different from it of the conventional generators. A method for making outage capacity probability table of WTG for reliability is proposed in this paper. The detail process is presented using case study of simple system.

A Real Business Cycle Model to Study the Effect of Overseas Oil Resource Development on the Korean Economy (실물경기변동 모형을 이용한 해외석유가스 개발사업의 경제적 효과분석)

  • Park, Hojeong;Kim, Jaekyung
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.179-197
    • /
    • 2016
  • The development of overseas resource is a driving force to secure the energy security in Korea with low sufficiency rate of energy. This paper analyzes the effect of overseas oil resource development on the economy by presenting a real business cycle model with consolidated energy price index. A linear-quadratic dynamic programming is adopted to raise computational transparency and efficiency. The analysis shows that the overseas oil resource development project during 2010 and 2012 decreases the energy price by 1.2% per annum which effect is equivalent to the positive 0.47% to the GDP. The implication calls for steady and robust support for overseas resource development projects to enhance energy resilience.

The Effect of Energy Efficiency Investment on Industry's Productivity Growth (에너지효율화 투자의 산업생산성 파급효과 분석)

  • Lee, Myunghun
    • Environmental and Resource Economics Review
    • /
    • v.20 no.2
    • /
    • pp.291-308
    • /
    • 2011
  • The success of a target of 'low-carbon green growth' depends on whether installing energy-saving capital would result in an increase in industry's productivity growth. Defining total factor productivity from a dual cost function, this paper estimates the contribution of energy efficiency investment to productivity growth by analyzing the sources of growth of productivity index for the primary metal industries. Empirical results show that, on average, energy efficiency investment increased the annual rate of productivity growth by 1.16 percentage points over th period 1982~2006. In addition, The scale effect positively affected the contribution of energy efficiency investment on productivity growth.

  • PDF

A Detailed Investigation of Solar Radiation Resources in South Korea (남한의 태양에너지 자원 정밀조사)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.59-62
    • /
    • 2011
  • The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth I s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2000. The Result of analysis shows that the armual-average daily global radiation on the horizontal surface is $3.56kWh/m^2/day$ and Estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

  • PDF

A Study of Energy Intake and Body Fat Percent of College Students in Seoul

  • Na, Hye-Bok;Kim, Sei-Ran
    • Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.105-109
    • /
    • 2000
  • To investigate the correlation between college women's energy intake and body fat percentage, this study was undertaken with 116 college women aged 19-24 years. The subjects were 20.9 years old on the average, and mean height and weight was 161.3 cm, 51.2 kg. Blood pressures were 112.4 mm Hg(systolic pressure), 70.2 mmHg(diastolic pressure). The number of pulse was 75.5 count/min. The energy intake and percent body fat were examined. The average intake of energy was 7652kcal/day(82.3% of RDA), which was lower than the recommended amount. It was similar to the level of energy intake of Korean women. BMI was 19.7 and body fat percent was 24.4%, so they appeared plump. According to BMI, 43.1% of subjects was grouped into normal, 56.9% was thin ; there was no difference between groups in age and stature. Also, normal group(27.1%) shoed significantly higher body fat percent(27.1%) than thin group(22.3%). But, body fat percent of thin group according to BMI was shown normal. Therefore, it may be thought that BMI is unsuitable indicator in this study. As a result of analyzing the correlation between body-measuring value and food intake, body fat percent against body weight and BMI was significant at the level p<0.001, but thee was no significant correlation with food intake. Therefore, it is desirable to recommend a healthful dietary lifestyle and activities for young women who want to reduce body weight due to excessive concerns regarding their outward figure.

  • PDF

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

Sodium titanate as an infrared reflective material for cool roof application

  • Ullah, Mahboob;Kim, Hee Jung;Heo, Jae Gu;Roh, Dong Kyu;Kim, Dae-Sung
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.spc1
    • /
    • pp.86-91
    • /
    • 2019
  • A solid-state route was used to prepare sodium titanium oxide (NTO, Na2Ti3O7) as a solar heat protecting material with an impressive solar reflectance (TSR = 94.3%) using a high refractive index rutile TiO2. The solar reflectance of the synthesized NTO was measured using UV-Vis-NIR spectrophotometer. Solar reflectance property of the synthesized compound depends on the calcination temperature. The solar reflectance property of the synthesized NTO powder was compared with commercial rutile TiO2. The compound synthesized at 900 ℃ for 24 hrs had remarkable solar reflectance 94.3% than that calcined below 900 ℃. Crystalline nature, structural property, morphology and optical properties of NTO powders were characterized and analyzed using XRD, FE-SEM, EDS and UV-Vis-NIR spectrophotometer. From the results, we guessed that NTO would be a suitable "solar heat protecting candidate" for energy-saving applications in coating industries.

Relationship between Exposure Index and Overheating Index in Complex Terrain (복잡지형에서 사면 개방도과 계절별 과열지수 사이의 관계)

  • 정유란;황범석;서형호;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.3
    • /
    • pp.200-207
    • /
    • 2003
  • '||'||'||'&'||'||'||'quot;Overheating index'||'||'||'&'||'||'||'quot;, the normalized difference in incident solar energy between a target surface and a level surface, is helpful in estimating the spatial variation in daily maximum temperature at the landscape scale. It can be computed as the ratio of the 4-hour cumulative solar irradiance surplus or deficit from that over a level surface to the maximum possible deviation (15 MJ $m^{-2}$ ) during the midafternoon. Ecosystem models may, for simplicity, use an empirical proxy (exposure index) variable combining slope and aspect in place of the overheating index to account for the variation of midafternoon solar irradiance. A comparative study with real-world landscape data was carried out to evaluate the performance of exposure index in replacing the overheating index. Overheating indices for summer solstice, fall equinox and winter solstice were calculated at 573,650 grid cells constituting the land surface of Donggye-Myun, Sunchang County in Korea, based on a 10-m DEM. Exposure index was also calculated for the same area and fitted for the variation of overheating index to derive a 2$^{nd}$ -order linear regression equation. The coefficient of determination ($R^2$) was 0.50 on summer solstice, 0.56 on fall equinox, and 0.44 on winter solstice, respectively. These are much lower than the theoretically calculated $R^2$ values ranging from 0.7 in summer to 0.9 in autumn. According to our study, exposure index failed to accurately predict the cumulative solar irradiance over a complex terrain, hindering its application to daily maximum temperature estimation. We suggest direct calculation of the overheating index in preference to using the exposure index.

Property of the Jurassic anthracite (Anthracite from the Seongju Area of the Chungnam Coalfield) (충남탄전(忠南炭田) 무연탄(無煙炭)의 특성(特性))

  • Park, Suk Whan;Park, Hong Soo
    • Economic and Environmental Geology
    • /
    • v.22 no.2
    • /
    • pp.129-139
    • /
    • 1989
  • The anthracite coalfields of Korea are confined to the areas where sedimentary rocks of Permian and Jurassic are preserved. The Chungnam coalfield lies in the sedimentary rocks of Jurassic which belongs to the Daedong Supergroup (the Nampo group). For the property analysis of each coal seam interbeded in Daedong Supergroup, Seongju area is chosen and twelve coalseams are taken. Many standard tests have been established for optical analysis (maceral analysis, coalification degree measurement), chemical analysis (proximate, ultimate analysis) and physical analysis (ignition temperature, ash fusion temperature, hardgrove grindability index and X-ray diffraction). The Jurassic anthracite mainly consist of vitrinite and macrinite and the range of the reflectance is $R_{max}$ 5.0-6.5 which means metaanthracite rank. By the chemical composition analysis, it shows low H/C and high O/C value compare with international average value. By the physical analysis, it has very high ignition temperature ($531-584^{\circ}C$) and ash fusion temperature ($1510-1700^{\circ}C$) and very low combustion velocity (0.2-1.9 mg/min). The very wide range of the hardgrove grindability index (46-132) means that the grindability controlled mainly by the structural conditions of coal bearing strata.

  • PDF