A New Algorithm for Unstable Mode Decision in the On-line Transient Stability Assessment (온라인 과도안정도 평가를 위한 새로운 불안정모드 선정 알고리즘)

  • Chang, Dong-Hwan;Kim, Jung-Woo;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1123-1128
    • /
    • 2008
  • The necessity of online dynamic security assessment is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices and energy margin. The method is a new version of our previous paper.[1] Case studies are showing very promising results.

Characteristics of Bio-diesel according to Irradiation for Ultrasonic Energy (초음파 에너지 조사에 따른 바이오 디젤 특성)

  • Park, Chungyeol;Choi, Dooseuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.214-220
    • /
    • 2015
  • Since resources of fossil fuels are limited, development of alternative energies is emphasized and research on new-regenerative energy is actively in progress worldwide. In present research, physical and chemical characteristics of mixed fuel are analyzed in detail for the different mixture rate of conventional and bio-diesel and ultrasonic irradiation time. Experimental setup consists of ultrasonic generator, vibrator, horn, and reflector. Various physical and chemical characteristics of fuel are investigated for volumetric mixture rate of bio-diesel from 0 to 100%. As results, viscosity and surface tension is increased as mixture rate of bio-diesel is increased. Also, molecular splits and reunions are increased and decreased repeatedly after some period of time as ultrasonic energy irradiation time is increased. As conclusion of experiments, Olefin rate, Branch index, and Aromatic rate are influenced by ultrasonic irradiation time.

Thermal Conductive Characteristics and Basic Properties of Bentonite Grouts for the Ground Heat Exchanger of Geo-source Heat Pump (지열히트펌프 지중열교환기용 벤토나이트계 그라우트재의 열전도특성 및 기본성능)

  • Bai, Kang
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.66-72
    • /
    • 2013
  • In this study, the thermal conductive characteristics and basic properties of the nine commercial products of bentonite grouts were studied. Six of the nine products for ground heat exchanger systems are imported and others for civil engineering are domestic. The thermal conductivities of all bentonite products are nearly similar among products. The free swell indexes, viscosities and filter losses of the ground heat exchanger grouts are lower than those of the civil engineering ones. These characteristics seem to increase of the fluidity to fill the bentonite slurry to bore-hall perfectly, rather than to prevent underground water penetration. Thus, the mixtures of bentonites and sands are recommended for high thermal conduction grouts.

A Study on Heating and Cooling Degree-Days Calculation Methods with NCDC Data (NCDC데이터를 활용한 냉난방도일 산정 및 계산방법에 관한 연구)

  • Seo, Dong-Hyun;Song, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.77-84
    • /
    • 2013
  • Degree-day method is very simple but essential index to estimate heating and cooling energy demand in buildings. It has been neglected, however, for the simplicity so it is difficult to find any DB for south Korean cities. Even meteorological department of S. Korea doesn't report the data officially. In this study, current methods that are being used in many countries are investigated and used to calculate degree-days of 35 south Korean cities with 30 years(1981~2010) historical data. The calculation result indicates that the error among 4 major methods are dependent on how daily or hourly temperature are treated in the calculation and how balance point temperature is defined. The errors of the methods are no larger than 6% relative to hourly degree-day method.

Analysis on Wind Turbine Degradation of the Shinan Wind Power Plant (신안풍력발전소 풍력터빈의 성능저하 분석)

  • Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.46-50
    • /
    • 2013
  • This paper investigated wind turbine degradation quantitatively by analyzing the short-term operation records of the Shinan Wind Power Plant. Instead of a capacity factor which is needed to be normalized its variability due to monthly wind speed change, this study suggests an analysis method by taking the difference between the theoretical power output calculated from the nacelle wind speed and actual power output as the quantitative index of performance degradation. For three-year SCADA data analysis of the Shinan Wind Power Plant, it was confirmed that power output degradation rate of 0.54% per year. This value is within the average reduction rate 0.4%/year~0.9%/year of normalized capacity factor of the onshore wind power plants in U.K. and Denmark; however, lower than the rate 2%/year of Canadian wind power plants.

Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio (표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구)

  • Sung, Uk-Joo;Cho, Soo;Jang, Cheul-Yong;Lee, Jin-Seong;Peak, Sang-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

A Study of Glycemic Index, Glycemic Load and Food Sources according to Body Mass Index in Female College Students (여대생의 체질량지수에 따른 Glycemic Index, Glycemic Load와 급원식품에 관한 연구)

  • Yeon, Jee-Young;Kim, Eun-Young
    • Korean Journal of Community Nutrition
    • /
    • v.17 no.4
    • /
    • pp.429-439
    • /
    • 2012
  • The purpose of this study was to evaluate nutrients intakes, glycemic index (GI), glycemic load (GL) according to body mass index (BMI) in female college students (n = 320). The study subjects were divided into 3 groups based on their body mass index, an underweight group (BMI < 18.5 kg/$m^2$, n = 55), a normal group (18.5 kg/$m^2$ ${\leq}$ < 23 kg/$m^2$, n = 231), and an overweight group (23 kg/$m^2$ ${\leq}$ BMI < 25 kg/$m^2$, n = 34). The food and nutrition intake data obtained by administering a 3-day food record and were analyzed by using Can pro 3.0 software. Anthropometric measurements were collected from each subject. Body weights and BMI of the underweight group were 45.9 kg, 17.6 kg/$m^2$, those of the normal group were 53.8 kg, 20.5 kg/$m^2$, and those of overweight group were 62.6 kg, 23.8 kg/$m^2$, respectively. The mean daily dietary GI of underweight, normal and overweight groups was 66.2, 65.8 and 66.5, respectively. These differences were statistically non-significant. The mean daily dietary GL of underweight, normal and overweight groups were 159.2, 149.4, and 148.9, respectively. The major food source of dietary GI and GL was rice in the three groups. Dietary GI and GL were not significantly correlated with obesity when adjusted for energy, carbohydrate and dietary fiber intake.

Study on Application of the Preserving Valuation Index for Environmental Management of a Stack Room (서고환경관리를 위한 보존성 평가지수 활용에 관한 연구)

  • Yoon, Dai-Hyun;Shin, Hyun-Chang
    • The Korean Journal of Archival Studies
    • /
    • no.31
    • /
    • pp.139-161
    • /
    • 2012
  • Donald K. Sebera model can quantitatively compare the preserving environment by calculating the preserving valuation index with changing only the temperature and humidity. In this study, Donald K. Sebera model was used in order to compare and evaluate the preserving valuation index on the best condition and the worst condition in the temperature and humidity range of public records management act. As the results, the preserving valuation index in the best conditions was larger 2.47 times than the worst conditions within the preserving environment permitted in public records management act. Also, the influence of the humidity on the preserving valuation index of a paper archives as decreasing the activation energy for the hydrolysis reaction was larger rather than temperature. Thus the preserving valuation index can easily evaluate the suitability of the temperature and humidity conditions for preserving a archives. Therefore it can be used as useful tool for preservation of archives on change of the temperature and humidity.

Quantitative Kinetic Energy Estimated from Disdrometer Signal (우적 크기 탐지기 신호로 산출한 정량적 운동에너지)

  • Moraes, Macia C. da S.;Sampaio, Elsa;Tenorio, Ricardo S.;Yoon, Hong-Joo;Kwon, Byung-Hyuk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.153-160
    • /
    • 2020
  • The kinetic energy of the rain drops was predicted in a relation between the rain rate and rain quantity, derived directly from the rain drop size distribution (DSD), which had been measured by a disdrometer located in the eastern state of Alagoas-Brazil. The equation in the form of exponential form suppressed the effects of large drops at low rainfall intensity observed at the beginning and end of the rainfall. The kinetic energy of the raindrop was underestimated in almost rain intensity ranges and was considered acceptable by the performance indicators such as coefficient of determination, average absolute error, percent relative error, mean absolute error, root mean square error, Willmott's concordance index and confidence index.

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.