• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.034 seconds

Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building (주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가)

  • Kim, Yong-Shik;Kim, Jung-Heon;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

Energy Efficient and Secure Multipoint Relay Selection in Mobile Ad hoc Networks

  • Anand, Anjali;Rani, Rinkle;Aggarwal, Himanshu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1571-1589
    • /
    • 2016
  • Nodes in MANETs are battery powered which makes energy an invaluable resource. In OLSR, MPRs are special nodes that are selected by other nodes to relay their data/control traffic which may lead to high energy consumption of MPR nodes. Therefore, employing energy efficient MPR selection mechanism is imperative to ensure prolonged network lifetime. However, misbehaving MPR nodes tend to preserve their energy by dropping packets of other nodes instead of forwarding them. This leads to huge energy loss and performance degradation of existing energy efficient MPR selection schemes. This paper proposes an energy efficient secure MPR selection (ES-MPR) technique that takes into account both energy and security metrics for MPR selection. It introduces the concept of 'Composite Eligibility Index' (CEI) to examine the eligibility of a node for being selected as an MPR. CEI is used in conjunction with willingness to provide distinct selection parameters for Flooding and Routing MPRs. Simulation studies reveal the efficiency of ES-MPR in selection of energy efficient secure and stable MPRs, in turn, prolonging the network operational lifetime.

Comparison of Predicted and Measured Resting Energy Expenditure in Overweight and Obese Korean Women (한국 과체중 및 비만 여성의 휴식대사량 측정 및 예측값의 비교)

  • Park, Ji-Sook;Yim, Jung-Eun
    • Korean Journal of Community Nutrition
    • /
    • v.23 no.5
    • /
    • pp.424-430
    • /
    • 2018
  • Objectives: The purpose of this study was to compare predictions and measurements of the resting energy expenditure (REE) of overweight and obese adult women in Korea. Methods: The subjects included 65 overweight or obese adult women ranging in age from 20~60 with a recorded body mass index (BMI) of 23 or higher. Their height, weight, waist-hip ratio, and blood pressure were measured. The investigator also measured their body fat, body fat percentage, and body composition of total weight without fat using Dual energy X-ray absorptiometry (DXA) and measured resting energy expenditure by indirect calorimetry. Measured resting energy expenditures were compared with predictions from six methods: Harris-Benedict, Mifflin, Owen, WHO-WH, Henry-WH, and KDRI. Results: Harris-Benedict predictions showed the smallest differences from measured resting energy expenditure at an accurate prediction rate of 70%. The study analyzed regression between measured resting energy expenditure and body measurements including height, weight and age. The formula proposed by this research is as follows: Proposed REE equation for overweight and obese Korean women = $721-(1.5{\times}age)+(0.4{\times}height)+(9.9{\times}weight)$. Conclusions: These findings suggest that age is a significant variable when predicting resting energy expenditure in overweight and obese women. Therefore, prediction of resting energy expenditure should consider age when determining energy requirements in overweight and obese women.

Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation (건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정)

  • Lee, Seung-No;Park, Se-Jun;Lee, In-Bok;Ha, Tae-Hwan;Kwon, Kyeong-Seok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Lee, Sang-Yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

Shelf Life Prediction of Seasoned Anchovies packaged with PET/EVOH Film (포장(PET/EVOH Film) 멸치조미가공품의 유통기한 예측)

  • Lee, Eui-Seok;Lee, Hyong-Ju;Bae, Jae-Seok;Kim, Yong-Kuk;Lee, Jong-Hyeouk;Hong, Soon-Taek
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.6
    • /
    • pp.827-832
    • /
    • 2013
  • An attempt is made to predict the shelf life of seasoned anchovies packaged with laminated film, composed of polyethylene terephthalate (PET) and ethylene vinyl alcohol (EVOH). First, a descriptive sensory analysis is carried out to determine the principal sensory quality index in seasoned anchovies. Then, the physicochemical quality index with high correlation to the principal sensory quality index is determined accordingly. Subsequently, with the physicochemical quality index, the shelf-life is estimated by using the Arrhenius equation. As for the sensory quality index, 'color' is determined as a principal sensory quality index. For all samples stored at 3 different temperatures (25, 35, $45^{\circ}C$), it is observed that the sensory score is shown to be over 2.5 until 60 days of storage period, which is the lowest acceptable level. In addition, the b-value, as a physicochemical quality index, is determined to have a high correlation to the sensory quality index. Further, the activation energy and the Q10 value for the b-value by the Arrhenius equation is found to be 11.24 kcal/mol, 1.385~2.011, respectively. Thus, it can be concluded that the shelf life of seasoned anchovies packaged with PET/EVOH film is estimated to be 279.44 days when stored at $20^{\circ}C$.

A Comparative Study Examining the Obesity Indices, Psychological Well-being Index Scores, and Nutrient Intakes of Daughters According to Their Mother's Degree of Obesity (어머니의 비만여부에 따른 딸의 비만지표, 사회심리적 건강지수, 영양소 섭취 비교)

  • Cho, Kang-Ok;Kim, Yeon-Soo
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.3
    • /
    • pp.209-217
    • /
    • 2008
  • The purpose of this study was to understand the effects a mother's degree of obesity has on her daughter's obesity index, psychological well-being index, and nutrient intakes. The daughters, as study subjects, were classified into two groups according to their mother's body mass index (BMI): an obese group [BMI>25 kg/m$^2$, mother obesity group (MOG)] and a normal weight group [BMI<25 kg/m$^2$, mother normal weight group (MNG)]. The daughters in MOG showed significantly higher percent ideal body weight values than the daughters in MNG (p<0.001). MOG and MNG had significantly different psychological well-being index scores in terms of being classified into a highly stressed group (p<0.001), potentially stressed group (p<0.05), and healthy group (p<0.001). Intakes of daily energy, protein, fat, thiamin, riboflavin, niacin, phosphorus, and iron were also significantly different (p<0.001) between MOG and MNG. In particular, the vitamin A and C intakes of the MNG daughters were significantly higher than those of the MOG daughters (p<0.001). Overall, the results showed that a mother's level of obesity was essentially related to her daughter's obesity index, psychological well-being index score, and nutrient intakes. Therefore, it seems necessary for mothers to maintain an ideal body weight to prevent obesity and diet related problems in their daughters.

  • PDF

Effect of Die Geometry on Expansion of Corn Flour Extrudate (사출구 구조에 따른 옥수수가루 압출성형물의 팽화특성)

  • Gu, Bon-Jae;Ryu, Gi-Hyung
    • Food Engineering Progress
    • /
    • v.15 no.2
    • /
    • pp.148-154
    • /
    • 2011
  • The objective of this study was to determine the effect of die geometry on expansion index of extruded corn flour. Water solubility index, water absorption index and specific mechanical energy (SME) input were analyzed to observe the relationship with die geometry. The feed moisture content was 20 and 25%. Die dimensions were tapered angle (57, 95o) and length/diameter (L/D) ratio of die land (0.67, 1.67 and 2.67). The SME input was the highest at 20% moisture content and 2.23E-10 m3 die constant. The sectional and volumetric expansion indices at 20% moisture were increased with increase in die constant. However, die constant did not influence sectional expansion index of corn flour extrudate at 25% moisture content. The extruded corn flour at 25% moisture content had higher longitudinal expansion index than those of extruded corn flour at 20% moisture content. Sectional expansion and longitudinal expansion index were negatively correlated. The water absorption index and water solubility index were not affected with the die constant.

The Effects of Walker Height on Muscle Activity in the Elbow Extensor and Energy Expenditure Index During Ambulation With Walkers (보행기 사용 시 보행기의 높이가 주관절 신전근 활성도와 에너지소모지수에 미치는 영향)

  • Lee, Young-Rok;Kim, Tack-Hoon;Roh, Jung-Suk;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.35-42
    • /
    • 2006
  • The walker provides stability for walking for people whose lower extremities are disabled. It is important to measure and determine the appropriate height of a walker to conserve energy and to improve function. The purposes of this study were to examine effects of walker height and gait velocity on triceps, latissimus dorsi muscle activation, and energy expenditure index (EEI) during ambulation with a walker. Fifteen healthy subjects participated in this study. Each subject was assigned a walker with one of three heights (high, standard, lower height) and of two gait velocities (comfortable gait velocity or fast gait velocity). Electromyographic data were collected from triceps and latissimus dorsi, and EEI was determined from each condition. Two-way repeated analysis of variance (ANOVA) was used to determine the statistical significance. Post hoc comparison was performed with the Bonferroni test. The results of this study were summarized as follows: 1. There was a significant difference in the %MVIC of triceps among different walker height factors. Post hoc comparison revealed that %MVIC of dominant triceps brachii was more significantly increased in patients who used the higher walker than those who used the lower walker (p<.05). 2. There were significant differences in the %MVIC of the latissimus dorsi among different walker height factors and gait velocity factors. Post hoc comparison revealed that the %MVIC of dominant latissimus dorsi was also more significantly increased in patients who used the higher walker than those who used the lower walker (p<.05) and in those who used the faster gait velocity than those who used the slower gait velocity (p<.05). 3. There were significant differences in the EEI among different walker height factors and gait velocity factors. Post hoc comparison revealed that the EEI was significantly increased among those who used higher and lower walkers compared with the standard walker. The EEI was also more significantly increased among those who used the fast gait velocity than those who used the slower gait velocity (p<.05). It has been concluded that increased muscle activation in triceps and latissimus dorsi was required when the walker height increased and that more energy was exp ended when the gait velocity increased. Therefore, from the findings of this study, it is recommended that walker height be adjusted according to the purposes of gait training and that healthy subjects conserve energy when ambulating with standard walkers in a comfortable gait velocity.

  • PDF

Correlation analysis between energy indices and source-to-node shortest pathway of water distribution network (상수도관망 수원-절점 최소거리와 에너지 지표 상관성 분석)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.989-998
    • /
    • 2018
  • Connectivity between water source and demand node can be served as a critical system performance indicator of the degree of water distribution network (WDN)' failure severity under abnormal conditions. Graph theory-based approaches have been widely applied to quantify the connectivity due to WDN's graph-like topological feature. However, most previous studies used undirected-unweighted graph theory which is not proper to WDN. In this study, the directed-weighted graph theory was applied for WDN connectivity analyses. We also proposed novel connectivity indicators, Source-to-Node Shortest Pathway (SNSP) and SNSP-Degree (SNSP-D) which is an inverse of the SNSP value, that does not require complicate hydraulic simulation of a WDN of interest. The proposed SNSP-D index was demonstrated in total 42 networks in J City, South Korea in which Pearson Correlation Coefficient (PCC) between the proposed SNSP-D and four other system performance indicators was computed: three resilience indexes and an energy efficiency metric. It was confirmed that a system representative value of the SNSP-D has strong correlation with all resilience and energy efficiency indexes (PCC = 0.87 on average). Especially, PCC was higher than 0.93 with modified resilience index (MRI) and energy efficiency indicator. In addition, a multiple linear regression analysis was performed to identify the system hydraulic characteristic factors that affect the correlation between SNSP-D and other system performance indicators. The proposed SNSP is expected to be served as a useful surrogate measure of resilience and/or energy efficiency indexes in practice.

Comparison of Beam Quality Index of High Photon Beam (고에너지 광자선의 선질 지표에 관한 비교)

  • 신동오;지영훈;박성용;박현주;김회남;홍성언;권수일;서태석;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1998
  • It is necessarily to evaluate the energy of X-ray emitted from linear accelerator in order to determine the accurate absorbed dose. The method of direct measurement for x-ray energy is very difficult and impractical. Therefore the method of using beam quality index is generally used. Several dosimetry protocols recommend the use of quality indices such as depth of dose maximum at radiation central axis, dose gradient, and dose level. The linear accelerator manufactures follow the recommendation as dosimetry protocols. The study was performed for us to select the most suitable parameter among the Quality indices as described above. For photon beams of 4, 6, 10, 15, and 21 MV nominal energies produced by four kinds of accelerators(Mitsubishi, Scanditronix, Siemens, Varian) in eleven institutions, We evaluated the x-ray energies obtained by the Quality indices as recommended by several dosimetry protocols and manufactures. Results showed that there were energy spreads according to the same accelerators and Quality indices even though nominal energies were same. It appeared that the percent depth dose at 10 cm (D$_{10}$(%)) gave the smallest deviation and spread of energies. As energies increased, the energy deviation increased for all the quality indices. It is desirable for the use of unified quality index to compare the evaluation of beam quality at different institutions.

  • PDF