• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.029 seconds

Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change - (공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 -)

  • Ye, Tae-Gon;Kim, Kwang-Hyun;Kwon, Young-Sang
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.1
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.

Realization of Information Visualization of Electric Power Monitoring System for MV/LV Distribution Customers

  • Kim Jae-Chul;Chu Cheol-Min;Knag Bong-Seok;Kim Yeong-Il;Choi Duck-Su;Kim Kwang-Soon;Ryu Seung-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.287-294
    • /
    • 2006
  • Recently, switchboards for MV/LV distribution customers have been united and digitalized rapidly. This paper proposes the effective information visualization method for the data measured from cubicle switchboards for MV/LV distribution customers. We developed the algorithm that analyzes abundant data measured by switchboards and displays them to overall users, such as fire information index, power condition index, switchboard safety index, and power diminution index. Using a touch screen made users to operate it easily. User interface was also improved by taking graphic visualization. We guess the information visualization method suggested in this paper shows the new direction that heavy electrical equipments including switchboards are going to develop in the future.

Preventive Control for Transient Security with Generation Rescheduling Based on Rotor Trajectory Index

  • Verma, Kusum;Niazi, K.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.465-473
    • /
    • 2015
  • The increasing need to improve transient security assessment of existing or forecasted operating conditions of networks by power system operators is major concern of the power system security monitoring problem at the Energy Management Systems. This paper proposes a preventive control of transient stability with generation rescheduling based on rotor trajectory index obtained using time domain simulations. This index may help power engineers in making operational decision and to obtain a generation configuration with better transient security dispatch. The effectiveness of the proposed methodology is demonstrated on IEEE 39-bus New England system for a three phase fault at different loading conditions with single and multiple line outage cases.

Atmospheric Clearness Index Analysis of Major Cities in Korea Peninsula Using Solar Radiation Measurement (태양에너지 측정에 의한 한반도 주요 도시의 대기청명도 분석)

  • Jo, Dok-Ki;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.174-177
    • /
    • 2008
  • The amount of incident solar rays on inclined surfaces with various directions has Since the atmospheric clearness index is main factor for evaluating atmosphere environment, it is necessary to estimate its characteristics all over the major cities in Korea Peninsula. We have begun collecting clearness index data since 1982 at 16 different cities in South Korea and estimated using empirical forecasting models at 12 different stations over the North Korea from 1982 to 2006. This considerable effort has been made for constructing a standard value from measured data at each city. The new clearness data for global-dimming analysis will be extensively used by evaluating atmospheric environment as well as by solar application system designer or users.

  • PDF

BMD Analysis according to the Obesity Index in a Group of Adults (비만도에 따른 성인들의 집단별 골밀도 분석)

  • Kim, Sun-Geun;Kweon, Dae-Cheol;Oh, Chan-Ho;Song, Woon-Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • Obesity which causing many physical and psychological problems is difficult to treatment. The purpose study was investigate relationships between weight, height, body mass index (BMI) and BMD of according to the low, normal, over, obesity, high group. According to obesity index, each group was divided into five proup. Study subjects were man(n=135) and woman(n=145). We checked the BMD of femoral neck and lumbar spine by using dual energy X-ray bone densitometry. Weight was positively correlation with height (p<0.05) by Pearson's correlation matrix. There was a significant difference in BMD of femoral neck and lumbar spine between four(low, normal, over, obesity) groups except for high obesity groul.

  • PDF

Group-indexed orthogonal frequency division multiplexing index modulation aided performance trade off

  • Anushya, Thomas Wilfred Edison Athisaya;Laxmikandan, Thangavelu;Manimekalai, Thirunavukkarasu
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.105-116
    • /
    • 2022
  • In this study, a novel group-indexed orthogonal frequency division multiplexing index modulation (OFDM-IM) scheme is proposed to achieve a tradeoff between spectral efficiency (SE) and bit-error-rate (BER) performance. In the proposed scheme, the total subcarriers in a group are divided into subgroups, and additional bits are transmitted by subgroup indexing, unlike the conventional OFDM-IM scheme, which uses index bits to select active subcarriers. With the proposed scheme, the additional degree of freedom provided by the number of active subgroups selected provides a tradeoff between spectral efficiency and BER performance. Decoding is performed in steps to reduce computional complexity in the decoder design. Simulaton results show that the number of active subgroups selected influences the proposed scheme's performance in terms of energy efficiency, spectral efficiency, and BER performance.

Energy Performance Evaluation of a New Commercial Building using Calibrated As-built Simulation with Monitoring Data (건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가)

  • Song, Su-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.155-166
    • /
    • 2008
  • The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures(ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index(EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building(i.e., calibrated as-built simulation mode]), but doesn't include the simulated ECDMs.

A Study on the Chamical and Physical Characteristics of Ultrasonic-Energy-Added Diesel Fuel (초음파 에너지 부가 지젤연료의 화학적, 물리적 특성에 관한 연구)

  • 최두석;윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.147-155
    • /
    • 1996
  • This study investigated the characteristics of ultrasonic-energy-added diesel fuel. We compared the characteristics used H-NMR spectrum, FT-IR spectrum, viscosity and surface tension between conventional diesel fuel and ultrasonic-energy-added diesel fuel. The result are obtained as follow : We knew that ultrasonic energy result to reduce BI and weaken viscosity and surface tension. Also, the ultrasonic energy caused to reduce aromatics Ha and increase Alkanes Hγ. The effect of ultrasonic-energy-added dieselfuel was principally caused by change of chemical structures and a physical characteristics.

  • PDF

Energy and Exergy Analysis of Maeeum-Ri Geothermal District Heating System (지열을 이용한 매음리 지역난방에 관한 에너지 및 엑서지 분석)

  • Kim, Jin-Sang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.2
    • /
    • pp.13-19
    • /
    • 2009
  • This study describes energy and exergy analysis of the Maeeum-Ri Geothermal District Heating System(MGDHS) of Ganghwa Island, Incheon, Korea. Design data are used to assess the performance of the geothermal district heating system. Geothermal resources of MGDHS are found to be low quality with specific exergy index of 0.029. Exergy losses occur in the pumps and heat exchangers as well as in the geothermal Quid and direct discharge. As a result, the total exergy losses accounts for 5.2% in pumps, 47% in the discharge, and 3.3% in heat exchanger based on the total exergy input to the entire MGDHS. The overall energy and exergy efficiencies of the system are found to be 28.8% and 44.5%, respectively.

  • PDF

Oil Spill Monitoring in Norilsk, Russia Using Google Earth Engine and Sentinel-2 Data (Google Earth Engine과 Sentinel-2 위성자료를 이용한 러시아 노릴스크 지역의 기름 유출 모니터링)

  • Minju Kim;Chang-Uk Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.311-323
    • /
    • 2023
  • Oil spill accidents can cause various environmental issues, so it is important to quickly assess the extent and changes in the area and location of the spilled oil. In the case of oil spill detection using satellite imagery, it is possible to detect a wide range of oil spill areas by utilizing the information collected from various sensors equipped on the satellite. Previous studies have analyzed the reflectance of oil at specific wavelengths and have developed an oil spill index using bands within the specific wavelength ranges. When analyzing multiple images before and after an oil spill for monitoring purposes, a significant amount of time and computing resources are consumed due to the large volume of data. By utilizing Google Earth Engine, which allows for the analysis of large volumes of satellite imagery through a web browser, it is possible to efficiently detect oil spills. In this study, we evaluated the applicability of four types of oil spill indices in the area of various land cover using Sentinel-2 MultiSpectral Instrument data and the cloud-based Google Earth Engine platform. We assessed the separability of oil spill areas by comparing the index values for different land covers. The results of this study demonstrated the efficient utilization of Google Earth Engine in oil spill detection research and indicated that the use of oil spill index B ((B3+B4)/B2) and oil spill index C (R: B3/B2, G: (B3+B4)/B2, B: (B6+B7)/B5) can contribute to effective oil spill monitoring in other regions with complex land covers.