• Title/Summary/Keyword: energy flux tower

Search Result 40, Processing Time 0.021 seconds

Development of Flux Mapping Technique for the Solar Power Tower Plant (타워형 태양열발전을 위한 열유속 분포 측정기술 개발)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Kang, Yong-Heack;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

Inferring Regional Scale Surface Heat Flux around FK KoFlux Site: From One Point Tower Measurement to MM5 Mesoscale Model (FK KoFlux 관측지에서의 지역 규모 열 플럭스의 추정 : 타워 관측에서 MM5 중규모 모형까지)

  • Jinkyu Hong;Hee Choon Lee;Joon Kim;Baekjo Kim;Chonho Cho;Seongju Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.138-149
    • /
    • 2003
  • Korean regional network of tower flux sites, KoFlux, has been initiated to better understand $CO_2$, water and energy exchange between ecosystems and the atmosphere, and to contribute to regional, continental, and global observation networks such as FLUXNET and CEOP. Due to heterogeneous surface characteristics, most of KoFlux towers are located in non-ideal sites. In order to quantify carbon and energy exchange and to scale them up from plot scales to a region scale, applications of various methods combining measurement and modeling are needed. In an attempt to infer regional-scale flux, four methods (i.e., tower flux, convective boundary layer (CBL) budget method, MM5 mesoscale model, and NCAR/NCEP reanalysis data) were employed to estimate sensible heat flux representing different surface areas. Our preliminary results showed that (1) sensible heat flux from the tower in Haenam farmland revealed heterogeneous surface characteristics of the site; (2) sensible heat flux from CBL method was sensitive to the estimation of advection; and (3) MM5 mesoscale model produced regional fluxes that were comparable to tower fluxes. In view of the spatial heterogeneity of the site and inherent differences in spatial scale between the methods, however, the spatial representativeness of tower flux need to be quantified based on footprint climatology, geographic information system, and the patch scale analysis of satellite images of the study site.

Quantitative Study of CO2 based on Satellite Image for Carbon Budget on Flux Tower Watersheds (플럭스 타워 설치 유역을 대상으로 탄소수지 분석을 위한 위성영상자료기반의 CO2 정량화 연구)

  • Jung, Chung Gil;Lee, Yong Gwan;Kim, Seong Joon;Jang, Cheol Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.109-120
    • /
    • 2015
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. This study is to estimate the $CO_2$ flux of South Korea using Terra MODIS image and to assess the reliability of MODIS data from the ground measured $CO_2$ flux by eddy covariance flux tower data at 3 locations (two at mixed forest area and one at rice paddy area). The MODIS Gross Primary Productivity (GPP) product (MOD17A2), 8-day composite at 1-km spatial resolution was adopted for the spatial $CO_2$ flux generation. The MOD17A2 data by noise like cloud and snow in a day were tried to fill by Inverse Distance Weighted (IDW) method from valid pixels and the damping effect of MOD17A2 data were corrected by Quality Control (QC) flag. The MODIS $CO_2$ flux was estimated as the sum of GPP and Re (ecosystem respiration) by Lloyd and Taylor method (1994). The determination coefficient ($R^2$) between MODIS $CO_2$ and flux tower $CO_2$ for 3 years (2011~2013) showed 0.55 and 0.60 in 2 mixed forests and 0.56 in rice paddy respectively. The $CO_2$ flux generally fluctuated showing minus values during summer rainy season (from July to August) and maintaining plus values for other periods. The MODIS $CO_2$ flux can be a useful information for extensive area, for example, as a reliable indicator on ecological circulation system.

Long Term Flux Variation Analysis on the Boseong Paddy Field (보성 농업지역에서의 장기간 플럭스 특성 분석)

  • Young-Tae Lee;Sung-Eun Hwang;Byeong-Taek Kim;Ki-Hun Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

Estimation of the Random Error of Eddy Covariance Data from Two Towers during Daytime (주간에 두 타워로부터 관측된 에디 공분산 자료의 확률 오차의 추정)

  • Lim, Hee-Jeong;Lee, Young-Hee;Cho, Changbum;Kim, Kyu Rang;Kim, Baek-Jo
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.483-492
    • /
    • 2016
  • We have examined the random error of eddy covariance (EC) measurements on the basis of two-tower approach during daytime. Two EC towers were placed on the grassland with different vegetation density near Gumi-weir. We calculated the random error using three different methods. The first method (M1) is two-tower method suggested by Hollinger and Richardson (2005) where random error is based on differences between simultaneous flux measurements from two towers in very similar environmental conditions. The second one (M2) is suggested by Kessomkiat et al. (2013), which is extended procedure to estimate random error of EC data for two towers in more heterogeneous environmental conditions. They removed systematic flux difference due to the energy balance deficit and evaporative fraction difference between two sites before determining the random error of fluxes using M1 method. Here, we introduce the third method (M3) where we additionally removed systematic flux difference due to available energy difference between two sites. Compared to M1 and M2 methods, application of M3 method results in more symmetric random error distribution. The magnitude of estimated random error is smallest when using M3 method because application of M3 method results in the least systematic flux difference between two sites among three methods. An empirical formula of random error is developed as a function of flux magnitude, wind speed and measurement height for use in single tower sites near Nakdong River. This study suggests that correcting available energy difference between two sites is also required for calculating the random error of EC data from two towers at heterogeneous site where vegetation density is low.

On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere (농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여)

  • Choi Taejin;Kim Joon;Yun Jin-il
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

Validation of Energy and Water Fluxes Using Korea Land Data Assimilation and Flux Tower Measurement: Haenam KoFlux Site's Hydro-Environment Analysis (Flux Tower 관측자료와 KLDAS를 이용한 Soil-Vegetation-Atmosphere Transfer 모형의 적용:해남 KoFlux 지점의 수문순환 환경분석에 대하여)

  • Kim, Daeun;Lim, Yoon Jin;Lee, Seung Oh;Choi, Minha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.285-291
    • /
    • 2011
  • Accurate assessment of the water and energy cycles is essential to understand hydrologic, climatologic, and ecological processes. Common Land Model (CLM) is one of the well-developed Soil-Vegetation-Atmosphere Transfer (SVAT) models based on the water and energy balance equation for accurate prediction of hydro-environmental cycles. The CLM can estimate realistic and reliable results using relatively simple parameters. It has been widely used in the world, however in Korea practical applications of the CLM are rare due to lack of information and input data. In this study, the CLM with Korea Flux network (KoFlux) and Kore Land Data Assimilation System (KLDAS) data were individually validated for domestic applications. This study showed that all comparisons between observations and model results from KoFlux and KLDAS had reasonable correlation with determination coefficient of 0.73~1.00 via regression. The results confirmed the applicability of the CLM and the possibility of the KLDAS usage for the region where input data are not existed.

Analysis of Energy Concentration Characteristics of Heliostat used in 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템에서 사용되는 Heliostat의 집열특성 분석)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.80-88
    • /
    • 2011
  • Heliostat in the tower type solar thermal power plant is a sun tracking mirror system to reflect the solar energy to the receiver and the optical performance of it affects to the efficiency of whole power plant most significantly. Thus a solid understanding of heliostat's energy concentration characteristics is the most important step in designing of the heliostat field and the whole power plant. The work presented here is the analysis of energy concentration characteristics of heliostat used in 200kW solar thermal power plant, where the receiver located at 43m high in tower has $2{\times}2$m rectangular shape. The heliostat reflective surface is formed by 4 of $1{\times}1$m flat plate mirror facet and the mirror facet is mounted on the spherical frame. The direct normal incident radiation models in vernal equinox, summer solstice, autumnal equinox and winter solstice are first derived from the actually measured data. Then the intercept ratio, heat flux distribution and total energy collected at the receiver for the heliostats located in the various places of the heliostat field are investigated. Finally the effect of mirror facet installation error on the optical performance of the heliostat is analyzed.

Validation of Net Radiation Measured from Fluxtower Based on Eddy Covariance Method: Case Study in Seolmacheon and Cheongmicheon Watersheds (에디공분산 방법 기반의 플럭스 타워 순 복사에너지 검증: 설마천, 청미천 유역)

  • Byun, Kyuhyun;Shin, Jiyae;Lee, Yeon-Kil;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • The necessity of clear understanding of water and energy cycles has been attracted recently due to the climate change. The micrometeorological flux tower networks play a role of cornerstone of the hydrological and ecological analyses. Although the eddy covariance techniques used for flux tower have been proven to be applicable for estimation of latent heat flux, the raw data are often underestimated and needs to be corrected. Among several methods, the Bowen ratio is recognized as the most useful method in which the net radiation and other flux data (Ground heat flux, Sensible heat flux) are used and needed to be validated. In this study, in order to validate the net radiation from flux tower in Seolmacheon and Cheongmicheon watersheds, we compare it with two version of calculated net radiation: (1) FAO 56 Daily net radiation proposed by Allen et al. (1998). (2) Instantaneous net radiation proposed by Bastiaanssen (1995). The results showed that the net radiation from the flux data had similar tendency with those calculated based on physical theory. In addition, after it was applied to Bowen ratio method, the corrected latent heat flux was considerably improved with making the energy balance much more closed.

Net Radiation Estimation Using Flux Tower Data and Integrated Hydrological Model: For the Seolmacheon and Chungmichen Watersheds (플럭스 타워 관측 자료 및 통합수문모형을 이용한 순복사량 산정: 설마천, 청미천 유역을 대상으로)

  • Kim, Daeun;Baek, JongJin;Jung, Sung-Won;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.3
    • /
    • pp.301-314
    • /
    • 2013
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. To understand energy flow, flux towers are up and running throughout the world. In step with, in domestic major areas, there have been observed using several flux towers. In this study, downward shortwave radiation, downward long wave radiation, and net radiation that take important part in hydro-meteorology and ecology were calculated by proposed physical equations using flux data of the Seolmacheon and Choengmicheon, then, the calculated net radiation and observed net radiation were individually compared and validated. The results confirmed applicability of physical methods for insufficient hydro-meteorological data and possibility for observed data of hydro-meteorological variables.