• Title/Summary/Keyword: energy direction

Search Result 2,140, Processing Time 0.036 seconds

Optimization Design of Commercial Large Gas Oven Systems (상업용 대형 가스오븐 시스템의 최적 설계)

  • Kim, Do-Hyun;Yu, Byeonghun;Kum, Sungmin;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.21-28
    • /
    • 2016
  • This research was conducted for the optimal design of large commercial gas oven system. Equivalent ratio was determined through a numerical analysis and experiments on the combustion condition of the combustor. After reviewing the supply capacity of burner(20,000 kcal) and control method of convection fan, two types of heat exchangers designed. In order to maintain a uniform temperature inside the oven is required convection fan braking system. The center temperature in the oven rises more rapidly when the convectional fan is rotated in the counterclockwise direction than the counter-clockwise direction. And The efficiency of the system by installing a large heat transfer area was higher.

Comparison of SPECT Images with $^{99m}Tc$ Collimators ($^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향)

  • Lee, Man-Koo;Lee, Jeong-Ok;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF

MEASUREMENT OF NUCLEAR FUEL ROD DEFORMATION USING AN IMAGE PROCESSING TECHNIQUE

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.133-140
    • /
    • 2011
  • In this paper, a deformation measurement technology for nuclear fuel rods is proposed. The deformation measurement system includes a high-definition CMOS image sensor, a lens, a semiconductor laser line beam marker, and optical and mechanical accessories. The basic idea of the proposed deformation measurement system is to illuminate the outer surface of a fuel rod with a collimated laser line beam at an angle of 45 degrees or higher. For this method, it is assumed that a nuclear fuel rod and the optical axis of the image sensor for observing the rod are vertically composed. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of the laser line beam position on the surface of the fuel rod is imaged as a parabolic beam in the high-definition CMOS image sensor. An ellipse model is then extracted from the parabolic beam pattern. The center coordinates of the ellipse model are taken as the feature of the deformed fuel rod. The vertical offset of the feature point of the nuclear fuel rod is derived based on the displacement of the offset in the horizontal direction. Based on the experimental results for a nuclear fuel rod sample with a formation of surface crud, an inspection resolution of 50 ${\mu}m$ is achieved using the proposed method. In terms of the degree of precision, this inspection resolution is an improvement of more than 300% from a 150 ${\mu}m$ resolution, which is the conventional measurement criteria required for the deformation of neutron irradiated fuel rods.

The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System (지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3))

  • Hahn, Jeongsang;Lee, Juhyun;Kiem, Youngseek;Lee, Kwangjin;Hong, Kyungsik
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

A Study on Changes in the Size of the Four Internal Organs in Taesoeumyang Persons according to the Movement of the Energy of Sorrow, Anger, Joy and Pleasure (애노희락지기(哀怒喜樂之氣)의 운동(運動)에 따른 태소음양인(太少陰陽人)의 사장대소(四臟大小) 변화(變化)에 대한 연구(硏究))

  • Cho, Young;Baik, You-Sang;Jeong, Chang-Hyun
    • Journal of Korean Medical classics
    • /
    • v.19 no.3
    • /
    • pp.100-127
    • /
    • 2006
  • The present study examined internal environment where the size of internal organs (廳服大小) of Taesoeumyang persons (太少陰陽人) is decided focused on nature and emotion (性情), taking note that there is a difference between the parts triggering the rise and fall (升降) of the energy of sorrow, anger, joy and pleasure (哀怒喜樂之氣) of nature and emotion(性情) and the parts expressing the results. Because nature energy is incoming energy (順動之氣), it infuses energy to parts where the energy of sorrow, anger, joy and pleasure reaches and, as a result, forms relatively large-size organs (偏大之臟). When the energy of the four internal organs is produced, the soul, spirit, mind and life (神靈魂?) of the internal organs, which are triggered by outgoing energy, are consumed and as a result emotion is produced at parts where the energy of sorrow, anger, joy and pleasure reaches. It forms relatively small-size organs (偏小之臟). This study examined the process, focused on the direction of the energy of the energy of sorrow, anger, joy and pleasure moving up straight, moving up diagonally, moving down diagonally and moving down straight.

  • PDF

A Study on the Heat Transfer Performance of an Energy-Nose Section in a Household Refrigerator-Freezer (가정용 냉장고의 에너지 노즈부 열전달 특성에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.574-580
    • /
    • 2007
  • The objective of this article is to present an analysis of all heat transfer paths through the energy nose under closed door conditions when refrigeration system of household refrigerator-freezer is operating on. Both experimental and numerical methods are suggested as a means of determining the overall energy nose load amount as well as the load due to each pathway such as mullion section and F and R sides of the household refrigerator-freezer. In other words, all loads determined in this article are just energy nose and not the loads seen by the refrigeration system. We suggest good ideas for improving the heat transfer losses such as conduction and convection through the energy nose. As we can be known from the experimental test results, it is effective to prevent the heat loss of a mullion section. And energy efficiency is also decreased approximately 6% compared to that of a baseline sample test result. As we can be known from the Ansys 8.1 analysis, it is shown the steady state temperature distribution in figures from 6 to 8. And the direction of the heat flow through the energy nose section is also easily seen from that In conclusion, the article is focused on an energy nose section in household refrigerator-freezer for practical proposes which is the energy saving in a household refrigerator-freezer. And the method suggested may be applied to any make or model to aid in the search for high efficient energy nose section of household side by side refrigerator-freezer as well as top mounted refrigerator-freezer, commercial refrigerator and so on.

Study on Thermal Stress Occurred in Concrete Energy Pile During Heating and Cooling Buildings (냉난방 가동 모사에 따른 콘크리트 에너지파일의 열응력 해석에 대한 연구)

  • Sung, Chihun;Park, Sangwoo;Kim, Byungyeon;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.2
    • /
    • pp.12-18
    • /
    • 2015
  • The energy pile, used for both structural foundations and heat exchangers, brings about heat exchange with the ground formation by circulating a working fluid for heating and cooling buildings. As heat exchange occurs in the energy pile, thermal stress and strain is generated in the pile body and surrounding ground formation. In order to investigate the thermo-mechanical behavior of an energy pile, a comprehensive experimental program was conducted, monitoring the thermal stress of a cast-in place energy pile equipped with five pairs of U-type heat exchanger pipes. The heating and cooling simulation both continued for 30 days. The thermal strain in the longitudinal direction of the energy pile was monitored for a 15 operation days and another 15 days monitoring followed, without the application of heat exchange. In addition, a finite element model was developed to simulate the thermo-mechanical behavior of the energy pile. A non-linear contact model was adopted to interpret the interaction at the pile-soil interface, and thermal-induced structure mechanics was considered to handle the thermo-mechanical coupled multi-field problem.

Evaluation on the Performance of Power Generation of Energy Harvesting Blocks for Urban and Housing Application (도시·주택 적용 미관용 에너지 블록의 발전성능 평가)

  • Noh, Myung-Hyun;Kim, Hyo-Jin;Park, Ji-Young;Lee, Sang-Youl;Cho, Young-Bong
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • A technology that newly attract attention in the area of energy-related study is the energy harvesting(or scavenging) technology. In this paper, the performance of power generation for the energy harvesting block with a combination of piezoelectric technology and electromagnetic technology among various energy harvesting technologies was investigated. The goal of this study is to evaluate on the applicability of our developed energy harvesting block into the field of urban & housing. First, we evaluated the performance of power generation for the multi-layer energy harvester at laboratory scale. Second, we described the features of our developed prototype module that includes amplification technologies to improve power density per module and evaluated the performance of power generation for the energy harvesting block in a variety of ways. From the test results, the developed product increased the performance of power generation up to 255% or 505% compared to the existing product and its superiority were shown. Finally, we suggested the direction for the improvement of the energy harvesting block module.

Fabrication of unidirectional commingled-yarn-based carbon fiber/polyamide 6 composite plates and their bend fracture performances (일방향 혼합방사형 탄소섬유/폴리아미드 6 복합재료판의 제작조건과 굽힘파괴거동)

  • Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.416-427
    • /
    • 1998
  • Unidirectional commingled-yarn-based carbon fiber(CF)/polyamide(PA) 6 composite was fabricated under molding pressures of 0.4, 0.6 and 1.0 MPa to study its flexural deformation and fracture behavior. Fiber/matrix interfacial bonding area became larger with an increase of molding pressure from 0.4 to 0.6 MPa. For molding pressures .geq. 0.6 MPa, good flexural performance of similar magnitudes was attained. For the fracture test, four kinds of notch direction were adopted : edgewise notches parallel (L) and transverse (T) to the major direction of fiber bundles, and flatwise notches parallel(ZL) and perpendicular(ZT) to this direction. Nominal bend strength for L and ZL specimens exhibited high sensitivity to notching. ZL specimens revealed the lowest values of the critical stress intensity factor $K_c$ which was slightly superior to those of unfilled PA6 matrix. Enlargement of the compression area for T specimens was analyzed by means of the rigidity reduction resulting from the fracture occurrence.

A Characteristics of Large Current and Minimum Quench Energy on Prototype High-$T_c$ Superconducting Cable (Prototype 고온초전도 케이블의 최소 Quench에너지 및 대전류 특성)

  • Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.236-242
    • /
    • 2000
  • NZP velocities were investigated on Ag sheathed multi filamentary Bi-2223 tape and direction type HTS cable. The critical current($I_c$) of Ag sheathed Bi-2223 tape and direction type HTS cable were 12 A, 63 A at 77 K, 0 T. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. In case of DC, the NZP velocities of numerical analysis and experiment were almost same. NZP velocities of direction type HTS cable were 1.9-2.4 cm/sec. The result shows that the total transport current of spiral type HTS cable in $LN_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to $I^2$ and higher than losses of inner layer. And in case of $I_p=I_c$, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer.

  • PDF