Development of Pilot Plant for Distributed Intelligent Management System of Microgrids (멀티에이전트 시스템을 이용한 마이크로그리드 분산 지능형 관리시스템 파일럿 플랜트 개발)

  • Oh, Sang-Jin;Yoo, Cheol-Hee;Chung, Il-Yop;Lim, Jae-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.322-331
    • /
    • 2013
  • This paper describes the development of the pilot plant of distributed intelligent management system for a microgrid. For optimal control and management of microgrids, intelligent agents area applied to the microgrid management system. Each agent includes intelligent algorithms to make decisions on behalf of the corresponding microgrid entity such as distributed generators, local loads, and so on. To this end, each agent has its own resources to evaluate the system conditions by collecting local information and also communicating with other agents. This paper presents key features of the data communication and management of the developed pilot plant such as the construction of mesh network using local wireless communication techniques, the autonomous agent coordination schemes using plug-and-play functions of agents and contract net protocol (CNP) for decision-making. The performance of the pilot plant and developed algorithms are verified via real-time microgrid test bench based on hardware-in-the-loop simulation systems.

Fabrication of Rubber Block by using Recycled Waste Tires (폐타이어 재활용 고무보도블럭의 제조에 관한 연구)

  • 김진국
    • Resources Recycling
    • /
    • v.4 no.4
    • /
    • pp.70-75
    • /
    • 1995
  • Waste tires arc used as landifill, combustion and recycling. Rccenllg. lhc recycling of waste tires received a great attentmu fiam all industries. Thc rccgcling methods for w s l e tires are classified inla three culegoljz, a whole tirc, cmmb rubha and energy. T h ~ ssl iidy invesligvled the pruduclion ol Lhc ruhhcr block by using clumh cubbel oI wasle Ires. The process 01 manulacluring the ~uhher block was co~lsislerl ol several slepc: collecting lilts, ctuilnng and grinding hrcs, mixing crumh ruhher wlth bmder. and shaping under heat and pressure The effccl ol binder on ll~e ~uecl~ilnicaplr opcrlics o l r uhher hlock war also investigalcd. The economic feaqihility of a surface treiilmcnl and multilayas on the rubber block was dclcimincd

  • PDF

A Study on the Cause and Measures of Itaewon Human Stampede Accident Using Delph-AHP Survey Method (Delph-AHP기법을 이용한 이태원 압사 사고에 대한 원인 및 대처방안 조사 연구)

  • Sarang Lim;Weon-Bin Im;Sang-Hoon Shin
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2024
  • Human stampedes were a major hazard that could occur during mass gatherings, but they have received limited attention in korea. However, after the 10.29 Itaewon disaster, this atmosphere has turned around. The cause of such an accident and how to prevent it should be considered. The main aim of this study is to identify the reason why did the accident happen at that time, the root cause, and the triggering cause with Delphi-AHP survey method. In addition, various preventive measures were investigated by experts to prevent accidents similar to 10.29 Itaewon disaster. Problems and solutions were presented by collecting expert opinions on the causes and preventive measures of the 10.29 Itaewon disaster. However, the opinion of the experienced peoples who experienced the risk at the Itaewon was not included, so further investigation is considered necessary.

Application of Microwave-HClO Leaching for On-board Recovery of Au in Hydrothermal Minerals (열수광물내 Au의 선상회수를 위한 마이크로웨이브-차아염소산 용출 적용성)

  • Kim, Hyun Soo;Myung, Eun Ji;Kim, Min Sung;Lee, Sung-Jae;Park, Cheon-young
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.3
    • /
    • pp.243-250
    • /
    • 2020
  • The purpose of this study is to find out the possibility of applying microwave-hypochlorous acid leaching to effectively leaching Au in hydrothermal minerals on board. The comparative leaching experiment were confirmed that the leaching rate of Au with(T1)/with out(T2) of microwave nitric acid leaching. In addition, the leaching rate of Au on the conventional leaching by mechanical agitation(T3) and microwave leaching was compared. The result of microwave nitric acid leaching(solid-liquid ratio; 10%, leaching temperature; 90 ℃, leaching time; 20 min) confined that the metal leaching rate was high in the order of As>Pb>Cu>Fe>Zn, and the content of Au in the leaching residue was increased from 33.77 g/ton to 60.02 g/ton. As a result of the comparative leaching experiment using a chloride solvent, the dissolution rate of Au was high in the order of T1(61.10%)>T3(53.30%)>T2(17.30%). Therefore, chloride, which can be manufactured using seawater and that can be recycled by collecting chlorine gas generated in the leaching process, is expected to be an optimal solvent for Au leaching. In addition, the application of microwaves is believed to be effective in terms of time, efficiency and energy.

Factors Affecting the Minimum Detectable Activity of Radioactive Noble Gases (방사성 노블가스 측정을 위한 최소검출방사능 산출의 조절인자)

  • Park, Ji-young;Ko, Young Gun;Kim, Hyuncheol;Lim, Jong-Myoung;Lee, Wanno
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 2018
  • Anthropogenic radioactive noble gases formed by nuclear fission are significant indicators used to monitor the nuclear activity of neighboring countries. In particular, radioactive xenon, owing to its abundant generation and short half-life, can be used to detect nuclear testing, and radioactive krypton has been used as a tracer to monitor the reprocessing of nuclear fuels. Released radioactive noble gases are in the atmosphere at infinitesimal amounts due to their dilution in the air and their short half-life decay. Therefore, to obtain reliable and significant data when performing measurement of noble gases in the atmosphere, the minimum detectable activity (MDA) for noble gases should be defined as low as possible. In this study, the MDA values for radioactive xenon and krypton were theoretically obtained based on the BfS-IAR system by collecting both noble gases simultaneously. In addition, various MDA methods, confidence level and analysis conditions were suggested to reduce and optimize MDA with an assessment of the factors affecting MDA. The current investigation indicated that maximizing the pretreatment efficiency and performance maintenance of the counter were the most important aspects for Xe. In the case of Kr, since sample activities are much higher than those of Xe, it is possible to change the target MDA or to simplification of the analysis system.

A Study on the Correlation between the Bell's Palsy and the 7-Zone-diagnostic System - Evaluated by the Patterns of Zone 2 of Factor AA - (구안와사와 7구역진단기의 상관성 연구 - Factor AA 제2구역의 유형을 중심으로 -)

  • Cho, Yi-Hyun;Lee, Jin-Bok;Im, Jeong-Gyun;Park, Ka-Young;Yook, Tae-Han;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.27 no.2
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 2 of Factor AA in CP-6000A (VEGA, Germany), 7-zone-diagnostic system and the factors of Bell's Palsy. Methods : This study was carried out with the data from factors of Bell's Palsy(age, sex, period after onset, postauricular pain, season which the disease happen, contributing factor). We made three groups according to the different patterns of Zone 2 of Factor AA in CP-6000A. The Factor AA pattern of Group A is that the red bar graph of zone 2 were lower than the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 2 was the normal range. The Factor AA pattern of Group C was that the red bar graph of zone 2 was higher than the normal range. After collecting the data about factors of Bel's Palsy to correspond with conditions of each group were selected, the data was analyzed statistically. Results : The values of number of patient and period after onset of group A was higher than group B and C. The values of ratio of postauricular pain of group B and C was higher than group A. The season of disease happened of group A is spring and winter, group B is winter and group C is summer and autumn. The contributing factor of disease happened of group A is none, and group B and C is stress and clod. Conclusions : In Bell's Palsy, it is thought that the red bar graph of zone 2 is lower, the group have lower energy(虛) and the energy has a character of cold(寒), and zone 2 is higher, the group has the higher energy(實) and the energy has a character of fire(熱).

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

A Model on a Bubbling Fluidized Bed Process for CO2 Capture from Flue Gas (연소기체로부터 CO2를 포집하는 기포 유동층 공정에 관한 모델)

  • Choi, Jeong-Hoo;Youn, Pil-Sang;Kim, Ki-Chan;Yi, Chang-Keun;Jo, Sung-Ho;Ryu, Ho-Jung;Park, Young-Cheol
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.516-521
    • /
    • 2012
  • This study developed a simple model to investigate effects of important operating parameters on performance of a bubbling-bed adsorber and regenerator system collecting $CO_2$ from flue gas. The chemical reaction rate was used with mean particles residence time of a reactor to determine the extent of conversion in both adsorber and regenerator reactors. Effects of process parameters - temperature, gas velocity, solid circulation rate, moisture content of feed gas - on $CO_2$ capture efficiency were investigated in a laboratory scale process. The $CO_2$ capture efficiency decreased with increasing temperature or gas velocity of the adsorber. However, it increased with increasing the moisture content of the flue gas or the regenerator temperature. The calculated $CO_2$ capture efficiency agreed to the measured value reasonably well. However the present model did not agree well to the effect of the solid circulation rate on $CO_2$ capture efficiency. Better understanding on contact efficiency between gas and particles was needed to interpret the effect properly.

Performance of Hybrid Solar Still Under Operating Conditions (하이브리드 태양열 해수담수기의 운전 조건별 성능실험)

  • Yeo, Se Dong;Lim, Byung Ju;Yu, Sang Seok;Chung, Kyung Yul;Park, Chang Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.511-519
    • /
    • 2017
  • In this study, we have performed tests to improve the productivity of hybrid solar stills, which can be operated by solar thermal energy and/or waste heat of exhaust gas from electrical generators. The experimental apparatus is a hybrid solar still with a $1m{\times}2m$ collecting area, which consists of a conventional simple solar still and a vertical multi-effect diffusion(MED) section. The experiments were conducted under various operating conditions, with two identical hybrid solar stills, using solar radiation as the energy source. The results of the tests showed that the yield of the hybrid solar still depends on the various operating conditions. Insulation at the side glasses and a lower basin seawater level increased the productivity of the hybrid solar still. Reflecting fins with less than 47% reflectivity unexpectedly decreased the total productivity. However, the various feeding flow rate of the seawater into MED part did not show clear effects on productivity in the tested range.

Analysis of Fatty Acid Composition and Methyl-ester Properties of Camellia and Tea Oil (동백나무와 차나무 기름의 지방산 조성 및 메틸에스테르 특성 분석)

  • Kim, Kwang-Soo;Lee, Yong-Hwa;Jang, Young-Seok;Choi, In-Hu
    • New & Renewable Energy
    • /
    • v.9 no.3
    • /
    • pp.36-42
    • /
    • 2013
  • To secure raw materials of biodiesel production, the possibility of camellia (C. japonica L.) and tea (C. sinensis L.) seed oil was studied to produce biodiesel. In this research, crude oil contents and fatty acid compositions of seeds were analyzed by Solxlet and Gas chromatography (GC). The oil contents in the seeds of camellia were 69.8%~73.8%, and tea were 26.3%~29.4%. Among the fatty acids of camellia and tea oil, oleic acid was dominant. The unsaturated fatty acids accounted for 88.4% and 80.2% of the whole fatty acids of camellia and tea seed oil. Total seed oil content and fatty acid composition of tea seed were influenced by collecting date. Across maturation period, oil content of tea seed averaged 18.3% on $6^{th}$ September increasing to 27.9% by $11^{th}$ October. For largest seed yield and oil content, the optimum time to harvest tea is in middle october, and camellia is late september and thereafter. The extraction efficiency of oil from seeds by extraction methods was determined. Biodiesel were synthesized in 92.1~92.8% yields from camellia and tea oils by transesterification. The biodiesel was characterized by its physical and fuel properties including oxidation stability, iodine value and cold filter plugging point (CFPP). Oxidation stability of camellia was 8.6~8.8 hours and tea was 2.9~3.6 at $110^{\circ}C$. Camellia oil had considerably better oxidation stability and CFPP than tea oil.