Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

A Study on Implementation of FEMS for Chemical Industry Complex (화학 산업단지 FEMS 구축 연구)

  • Soo-Min Yoo;Soo-Woong Back;Jung-Min Lim;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • It is not easy to implement an energy management system in an industrial complex where small businesses are scattered, so the method of collecting and adjusting energy-related data is mainly used. FEMS is a system that responds to the demand for a paradigm shift from a passive energy management method to an active energy management method using IoT and ICT. In this study, a factory energy management system(FEMS) is designed for small and medium-sized enterprises located in chemical industrial complexes. Efficiency was confirmed by reviewing energy saving measures and efficiencies through FEMS for the electric energy of facilities built in each company. The cost effectiveness of FEMS is created when it is utilized by responsible and empowered personnel within the business processes of the host company. Therefore, it is necessary to utilize EMS that can be applied to the planning, support, operation and evaluation, and continuous improvement of the energy management system to achieve corporate organization and energy management goals.

A Study on the Change in Production Costs and Electricity Tariffs with the Introduction of Renewable Portfolio Standard (RPS(Renewable Portfolio Standard) 제도 도입을 고려한 전기요금변화에 관한 연구)

  • Hong, Hee-Jung;Han, Soek-Man;Kim, Bal-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.708-717
    • /
    • 2009
  • Recently, Korea government decided to introduce RPS (Renewable Portfolio Standard) mechanism which requires electricity providers to gradually increase the amount of renewable energy sources such as wind, solar, bioenergy, and geothermal. As a consequence, it is expected that the long-term fuel mix would be changed to result in more expensive production and the increased production costs would be distributed to the rate payers via electricity tariffs. This paper presents the change in long-term fuel mix in year 2020 with the four RPS scenarios of 3%, 5%, 10% and 20%, and the methodologies for collecting the increased production costs through new tariff schedule. The studies on long-term fuel mix have been carried out with the GATE-PRO (Generation And Transmission Expansion Program) optimization package, a mixed-integer program developed by the Korea Energy Economics Institute and Hongik university. Three methodologies for distributing the production costs to the rate payers have also been demonstrated.

LEACH Protocol based WSN Protocol using Fuzzy

  • Kwon, Oh Seok;Jung, Kye-Dong;Lee, Jong-Yong
    • International journal of advanced smart convergence
    • /
    • v.6 no.3
    • /
    • pp.59-64
    • /
    • 2017
  • A wireless sensor network is a network in which nodes equipped with sensors capable of collecting data from the real world are configured wirelessly. Because the sensor nodes are configured wirelessly, they have limited power such as batteries. If the battery of the sensor node is exhausted, the node is no longer usable. If more than a certain number of nodes die, the network will not function. There are many wireless sensor network protocols to improve energy efficiency, among which LEACH Protocol is a typical example. The LEACH protocol is a cluster-based protocol that divides sensor space into clusters and transmits and receives data between nodes. Therefore, depending on how the cluster is structured, the shape of the energy cow may decrease or increase. We compare the network lifetimes of the existing LEACH protocols and the three types of protocols that have been improved using fuzzy methods for cluster selection.

A Study on the PM Oxidation Characteristics of Electrical Heater DPF System (전기히터방식 매연여과장치의 PM 산화 특성에 관한 연구)

  • Ham, Yun-Young;Kim, Dae-Ha;Kim, Kyung-Woon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.183-190
    • /
    • 2006
  • For continuously regenerative PM collecting system which adopted thermally stable SiC DPF and electrical heater which was placed upstream of the filter and driven by well constructed control logic, PM oxidation characteristics were investigated varying air flow rate, amounts of PM accumulated on the DPF and filter inlet temperature in order to get optimized PM regeneration performance. This study showed that the operating condition of air flow rate 70 lpm, high PM loading around 30g and filter inlet temperature $700^{\circ}C$ with heat insulation was effective in achieving high regeneration efficiency. Also, in this condition, we could decrease the electric energy consumption by reducing the regeneration time.

A Study on the Condensation Characteristics with Solar Radiation and Tilted Angles for Using Solar Water Purifying System (태양열 정수시스템 이용을 위한 일사량과 경사각에 따른 응축특성에 관한 연구)

  • Lee, Cheun-Gi;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.59-65
    • /
    • 2009
  • In this paper, to find effective way of the production of the distilled water with solar radiation, 4 different boxes of condensation systems were compared. The bottom size of boxes are identical but the angles of top collecting plates are different. During the solar radiation, condensation did not occur and the condensation start when solar radiation was decreased. The maximum condensation reached when the temperatures of the top and bottom parts are equal. The condensation was continued until sunrise with gradually reduced amount. When top plate angle was $45^{\circ}$, condensation was highest compared with the other angles.

The Effects of Alpha Particles on the Sense Amplifier in Memory Devices (알파 입자가 기억소자의 SENSE AMP에 미치는 영향)

  • 이성규;한민구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.675-683
    • /
    • 1991
  • When alpha particles are incident into the substrate, we have calculated the advanced current caused by collecting charges as a function of time, the energy of alpha particle, and the carrier concentration of the substrate. Employing SPICE, we have compared two circuits of which one has dummy cell and another has dummy line instead of dummy cell, and both are connected to the bit line node including sense amplifier and cell within the memory device. From the numerical analysis, (it may be conjectured that)the smaller energy of alpha particle and the lower concentration of the substrate, the more possibility of misoperation due to alpha particles. It may be also found that the effects of alpha particle are substantially reduced in the circuit without dummy cell.

  • PDF

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.

Analysis of Characteristics on the Static Electricity by Streaming Electrification (유동대전에 의한 정전기 특성 분석)

  • Kim, Gil-Tae;Lee, Jae-Keun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.42-46
    • /
    • 2005
  • The static electricity by thinner flow and discharge energy is investigated experimentally for the purpose of preventing the electrostatic discharge and damage. Test system for evaluating streaming electrification consists of a teflon pipe, a reservoir tank a pump, flowmeters and an electrometer. When dielectric liquid flows through a pipe from one vessel to another, the potential difference generated in the collecting vessel is due to the accumulation of charges. These charges result from the convection of a part of the electrical double layer existing in the tube at the contact between the liquid and the inner wall. When the fluid velocity increases, the electric current increases proportionally. The charging current and accumulated charges by streaming electrification at the thinner velocity of 40cm/s are measured a range of 5 nA and $0.27{\mu}C$ respectively. This amount of static discharge energy generated by streaming electrification is enough to ignite flammable solvent. Therefore surface electric potential should decrease by using electrostatic shielding and ground.

An Experimental Study on the Bee Venom Collector Using the Photovoltaic System (전원장치로 태양광을 이용하는 봉독 채집기에 관한 실험적 연구)

  • Cho, Nam-Cheol;Lee, Chae-Moon;Kim, Choul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.122-127
    • /
    • 2011
  • A bee venom is very useful and expensive medical resource. A bee venom collector has some difficulties and inconveniences because of its complex component. This is used normal battery as an electric power. However, using the solar cell of the bee venom collector reduces economic burden and guarantees high efficiency. We have performed comparative experiment between the bee venom collector to use battery and the one to use solar cell(polycrystalline silicon) by collecting the bee venom simultaneously. At the same electricity, the electric frequency(AC),312 Hz is more superior than 450Hz. This paper verified through the experiments that the bee venom collector to adopt solar cell is more effective than normal collector.