• Title/Summary/Keyword: energy balancing

Search Result 298, Processing Time 0.031 seconds

A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories (대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구)

  • Seo, Won-Duck;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

Implementation of LMPR on TinyOS for Wireless Sensor Network (전송 부하를 분산하는 무선 센서 네트워크 구축을 위한 TinyOS 기반 LMPR 구현)

  • Oh, Yong-Taek;Kim, Pung-Hyeok;Jeong, Kug-Sang;Choi, Deok-Jai
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.136-146
    • /
    • 2006
  • In Wireless Sensor Network(WSN) a sensor node transfers sensing data to the base-node through multi-hop because of the limited transmission range. Also because of the limited energy of the sensor node, the sensor nodes are required to consume their energy evenly to prolong the lifetime of the network. LMPR is a routing protocol for WSN, LMPR configures the network autonomously based on level which is the depth from the base-node, and distributes the transmission and computation load of the network to each sensor node. This paper implements LMPR on TinyOS and experiments on the performance of LMPR in WSN. As the result, the average of the received rate of LMPR is 91.39% and LMPR distributes the load of the transmission and computation about 4.6 times compare to the shortest cost routing protocol. We expect LMPR evenly distributes the transmission and computation load of the network to each node, and the lifetime of the network will be longer than it used to be.

  • PDF

A Routing Algorithm for Wireless Sensor Networks with Ant Colony Optimization (개미 집단 최적화를 이용한 무선 센서 네트워크의 라우팅 알고리즘)

  • Jung, Eui-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.131-137
    • /
    • 2007
  • Recently, Ant Colony Optimization (ACO) is emerged as a simple yet powerful optimization algorithm for routing and load-balancing of both wired and wireless networks. However, there are few researches trying to adopt ACO to enhance routing performance in WSN owing to difficulties in applying ACO to WSN because of stagnation effect. In this paper, we propose an energy-efficient path selection algorithm based on ACO for WSN. The algorithm is not by simply applying ACO to routing algorithm but by introducing a mechanism to alleviate the influence of stagnation. By the simulation result, the proposed algorithm shows better performance in data propagation delay and energy efficiency over Directed Diffusion which is one of the outstanding schemes in multi-hop flat routing protocols for WSN. Moreover, we checked that the proposed algorithm is able to mitigate stagnation effect than simple ACO adoption to WSN.

  • PDF

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

Single Phase 5-level Inverter with DC-link Switches (DC링크 스위치를 갖는 단상 5레벨 인버터)

  • Choi, Young-Tae;Sun, Ho-Dong;Park, Min-Young;Kim, Heung-Geun;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.283-292
    • /
    • 2011
  • This paper proposed a new multi-level inverter topology based on a H-bridge with two switches and two diodes connected to the DC-link. The output voltage of the proposed topology is quite closer to a sinusoidal waveform compared with a typical single phase inverter. The proposed multi-level inverter is applicable to a power conditioning system for renewable energy sources, and it can be also used as a building block of a cascaded multi-level inverter for a high voltage application. In case of conventional H-bridge type or NPC type multi-level inverter, 8 controllable switches are used to obtain a 5 level output voltage, but the proposed multi-level inverter requires only 6 controllable switches. Thus the circuit configuration is quite simple, reliable and cost-effective implementation is possible. The efficiency can be improved owing to the reduction of the switching loss. A new PWM method based on POD modulation is suggested which requires only one carrier signal. The switching sequence to make the capacitor voltage balanced is also considered. The feasibility is studied through simulation and experiment.

Hopping Routing Scheme to Resolve the Hot Spot Problem of Periodic Monitoring Services in Wireless Sensor Networks (주기적 모니터링 센서 네트워크에서 핫 스팟 문제 해결을 위한 호핑 라우팅 기법)

  • Heo, Seok-Yeol;Lee, Wan-Jik;Jang, Seong-Sik;Byun, Tae-Young;Lee, Won-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2340-2349
    • /
    • 2009
  • In this paper we proposed a hopping routing scheme to resolve the hot spot problem for periodic monitoring services in wireless sensor networks. Our hopping routing scheme constructs load balanced routing path, where an amount of energy consumption of all nodes in the sensor networks is predictable. Load balanced routing paths can be obtained from horizontal hopping transmission scheme which balances the load of the sensor nodes in the same area, and also from vertical hopping transmission scheme which balances the load of the sensor nodes in the other area. The direct transmission count numbers as load balancing parameter for vertical hopping transmission are derived using the energy consumption model of the sensor nodes. The experimental results show that the proposed hopping scheme resolves the hot spot problem effectively. The efficiency of hopping routing scheme is also shown by comparison with other routing scheme such as multi-hop, direct transmission and clustering.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

The Association of Body Mass Index with Dietary Intake, Serum Lipid Levels, Lipoprotein(a) and PAI-1 in Middle Class Korean Adults from 1995 to 1999 (한국인 체질량지수와 식이 섭취, 혈청지질 및 동맥경화 위험인자와의 연관성 오년간의 연구조사(1995~1999))

  • 김진옥;위효정
    • Korean Journal of Community Nutrition
    • /
    • v.6 no.1
    • /
    • pp.51-68
    • /
    • 2001
  • This investigation studied the relationship between Body Mass Index(BMI) and dietary intake, levels of serum lipid, lipoprotein(a) and plasminogen activator inhibitor-1(PAI-1) of 28.449 Korean adults(16.937 men, 11.542 women) from 1995 to 1999. The dietary assessment was conducted using 24-hour dietary records and food frequency questionnaires. During this five year study, the BMI normal-weight group, as a percentage of the annual test population, decreased from 68.0% to 60.2%, while the BMI overweight and obese groups collectively increased from 25.0% to 29.7%. The levels of serum total cholesterol (TC), LDL-cholesterol(LDL-C), Triacylglycerol(TG) and PAI-1 increased as the values of BMI increased, while the levels of HDL-cholesterol(HDL-C) and lipoprotein(a)(men only) appeared to decrease as values of BMI increased. The levels of daily energy intake also increased as values of BMI increased in both men and women. The obese group had significantly higher levels of carbohydrate, protein, fat(men only), and cholesterol intake than those of the normal-weight, underweight, and overweight groups. In men, BMI positively correlated with the levels of macronutrients and cholesterol intake(p<0.001), % energy of protein, fat, and alcohol intake(p<0.001), and the levels of serum TC, LDL-C, TG and PAI-1(p<0.001), while BMI negatively correlated with % energy of carbohydrate intake, and the levels of Lp(a) and HDL-C(p<0.001). In women, BMI negatively correlated with level of cholesterol(p<0.01), fat(p<0.001), alcohol intake(p<0.05),% energy of fat (p<0.001), % energy of alcohol intake and level of and HDL-C(p<0.001). Subjects who had serum TC, LDL-C, HDL-C, and TG levels greater than the standard reference values(TC>240mg/㎗, LDL-C>130mg/㎗, HDL-C>35, TG>200mg/㎗) exhibited a higher intake of the three macronutrients, iron, calcium, meat, milk and fatty foods than those subjects who had serum lipid concentrations less-than-or-equal-to the standard reference values. Overall, there was positive correlation between the high risk factors of vascular disease variables, dietary intake, and BMI. Prevalence of hypertension and high blood sugar were increased as BMI increased, but the prevalence of hypertension is decreased as the year goes by. These findings showed that dietary intake, level of serum lipids and other vascular disease risk factors increased as BIM increased. Therefore, middle or upper class Korean adults who have high BMI should improve their eating habits. This involve reducing alcohol, animal fat, high carbohydrate foods, and overall food intake, and balancing intake in order to lower vascular disease risk factors, including obesity.

  • PDF

A Study on the Integration Costs in Korean Electric System in Accordance with Increasing Solar and Wind Power Generation (태양광·풍력 발전 증가에 따른 한국의 전력시스템 내 통합비용에 관한 연구)

  • Kim, Doo Chun;Kim, Kwang Jin;Park, Jung Gu
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.42-54
    • /
    • 2019
  • The solar and wind power is spreading as a means to $CO_2$ reduction, but it has the characteristics of the volatility depending on the weather changes. This article aims to estimate the additional integration costs in Korea electric system in response to such volatility of increasing solar and wind power generation, using Korea electric power trading analyzer(KEPTA). The analysis utilizes the statistics of "8th Basic Plan for Long-term Electricity Supply and Demand" and "Renewable Energy Plan 3020". As the results, integration costs will be estimated 13.94Won/kWh~32.55Won/kWh, consisting of 8.94Won/kWh as back-up costs, 1.03Won/kWh~4.45Won/kWh as balancing costs, and 3.97Won/kWh~19.16Won/kWh as grid-costs. These results suggest that when the integration costs are secured, Korea electric system will be expected in the stable situation. This article leaves the further studies with taking the technological development of solar and wind power generation, the introduction of energy storage system, and wholesale price of electricity into consideration.

Seismic Traveltime Tomography in Inhomogeneous Tilted Transversely Isotropic Media (불균질 횡등방성 매질에서의 탄성파 주시토모그래피)

  • Jeong, Chang-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.229-240
    • /
    • 2007
  • In this study, seismic anisotropic tomography algorithm was developed for imaging the seismic velocity anisotropy of the subsurface. This algorithm includes several inversion schemes in order to make the inversion process stable and robust. First of all, the set of the inversion parameters is limited to one slowness, two ratios of slowness and one direction of the anisotropy symmetric axis. The ranges of the inversion parameters are localized by the pseudobeta transform to obtain the reasonable inversion results and the inversion constraints are controlled efficiently by ACB(Active Constraint Balancing) method. Especially, the inversion using the Fresnel volume is applied to the anisotropic tomography and it can make the anisotropic tomography more stable than ray tomography as it widens the propagation angle coverage. The algorithm of anisotropic tomography is verified through the numerical experiments. And, it is applied to the real field data measured at limestone region and the results are discussed with the drill log and geological survey data. The anisotropic tomography algorithm will be able to provide the useful tool to evaluate and understand the geological structure of the subsurface more reasonably with the anisotropic characteristics.