• Title/Summary/Keyword: energy absorber

Search Result 406, Processing Time 0.026 seconds

Effect of a non-absorbable gag on the absorption process in a vortical tube absorber (수직원관형 흡수기의 흡수과정에 미치는 비흡수가스의 영향)

  • 허기준;정은수;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.456-465
    • /
    • 1998
  • Effect of a non-absorbable gas on the absorption process in a vertical tube absorber was investigated numerically. The water vapor mined with air as the non-absorbable gas is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. It was shown that the local absorption rate decreases as the mass fraction of air in water vapor increases. The vapor pressure of water at the liquid-vapor interface reduces significantly since the non-absorbable gas is accumulated near the interface. The effect of non-absorbable gases on absorption rate becomes larger as the mass flow rate of the vapor decreases. For small amount of non-absorbable gases the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. Total absorption rate increases as the mass flow rate of the vapor increases for large concentration of non-absorbables at the inlet of an absorber.

  • PDF

Effect of Nano Silver Coating on the Mechanical Properties and Hand of Cotton Fabrics (은나노 코팅이 면직물의 역학적 특성과 태에 미치는 영향)

  • Kang, Mi-Jung;Kwon, Young-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.8
    • /
    • pp.1273-1279
    • /
    • 2009
  • This study examined the difference in the mechanical properties of cotton fabrics treated with nano silver. Nano silver powder, UV-absorber, and DMDHEU are applied to cotton fabrics. The reagents added in a finishing solution were Triton X-100 and $MgCl_2$ $6H_2O$. The mechanical properties of the fabrics were measured by KES-FB system. From these, the primary hand values were evaluated by the conversion equation (KN-202-DS). The results of this study are summarized as follows. The fabric tensile properties and bending properties are increased by the application of nano silver, DMDHEU, and UV-absorber mixed. The values of tensile properties in the warp direction were significantly lower than those in the weft direction. However, the values of bending properties in the warp direction were higher than those in the weft direction. The differences in the values of compression parameters by nano silver coating were unnoticeable. However, the compression energy and resilience of compression in each fabric was increased by DMDHEU treatment. The SMD values of cotton fabrics are decreased by nano silver, DMDHEU, and UV-absorber mixed treatment.

The effects of Se evaporation temperature on CIS absorber layer fabricated by non-vacuum process (Se 증발온도가 비진공 공정으로 제조한 CIS 광흡수층에 미치는 영향)

  • Park, Myoung-Guk;Ahn, Se-Jin;Yoon, Jea-Ho;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.441-443
    • /
    • 2008
  • A non-vacuum process for fabrication of $CuInSe_2$ (CIS) absorber layer from the corresponding Cu, In solution precursors was described. Cu, In solution precursors was prepared by a room temperature colloidal route by reacting the starting materials $Cu(NO_3)_2$, $InCl_3$ and methanol. The Cu, In solution precursors were mixed with ethylcellulose as organic binder material for the rheology of the mixture to be adjusted for the doctor blade method. After depositing the mixture of Cu, In solution with binder on Mo/glass substrate, the samples were preheated on the hot plate in air to evaporate remaining solvents and to burn the organic binder material. Subsequently, the resultant CI/Mo/glass sample was selenized in Se evaporation in order to get a solar cell applicable dense CIS absorber layer. The CIS absorber layer selenized at $530^{\circ}C$ substrate temperature for 30 min with various Se gas evaporation temperature was characterized by XRD, SEM, EDS.

  • PDF

The Effects of Design Parameter Uncertainty of the Shock Absorber on the Performance of Suspension System (충격 흡수기의 설계 파라미터 불확실성이 현가 장치 성능에 미치는 영향)

  • Lee, Choon-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.949-958
    • /
    • 2020
  • The functions of shock absorbers are to dampen body, suspend motions, dissipate impact energy, and control tire force variation. During the operation, hydraulic oil is passed between the chambers via a flow restrictions. Therefore the damping force characteristics of shock absorber is determined by the characteristics of orifices and flow restrictions. The uncertainty in design variable affects the performance of suspension system strongly. But, the researches about the influence of uncertainty in design variable such as a fluid restriction's property of shock absorber, on the suspension system performance was hardly ever proposed. In this paper, we used statistical method of Latin Hypercube sampling, and the effects of design variables uncertainty on the performance of suspension system was presented.

Effects of a Non-absorbable Gas on the Absorption Process in a Vertical Tube Absorber

  • Hur, ki-Joon;Jeong, Eun-Soo;Jeong, Si-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.69-78
    • /
    • 1999
  • Effects of a non-absorbable gas on the absorption process in a vertical tube absorber has been investigated numerically. The water vapor mixed with air is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. The local absorption rate has been shown to decrease as the mass fraction of air in the water vapor increases. The vapor pressure of water at the liquid-vapor is interface reduced significantly since the non-absorbable gas accumulates near the interface. The effects of non-absorbable gases on absorption rate become larger as the mass flow rate of the vapor decreases. For a small amount of non-absorbable gases, the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. The total absorption rate increases as the mass flow rate of the vapor increases for large concentrations of non-absorbable gases at the inlet of an absorber.

  • PDF

Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube (표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구)

  • Chun, Tae-Kyu;Yang, Young-Joon;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House (공동주택 층간단열 완충재의 열에너지 특성의 관한 연구)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon;Cho, Woo-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

Drop Test of an Oleo-pneumatic Landing Gear (유공압 착륙장치 낙하시험)

  • Kim, Tae-Uk;Lee, Sang-Wook;Shin, Jeong-Woo;Lee, Seung-Kyu;Kim, Sung-Chan;Hwang, In-Hee;Kang, Shin-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1130-1135
    • /
    • 2010
  • The main function of a landing gear is to absorb the impact energy during touchdown. Most landing gear use an oleo-pneumatic shock absorber which essentially consists of an oil damper and a gas spring. The performance of a shock absorber can be estimated by analysis but it should be verified by drop test, which is required by MIL Spec. and FAR. In the drop test, various data such as ground loads, shock absorber pressure, stroke and mass travel are analyzed to validate the shock absorbing efficiency and the mathematical model for analysis. This paper presents the introduction of drop test facility, the test procedure and data evaluation method with real drop test example.

Effect of Wavy Flow of Vertical Falling Film on the Absorption Performance (흡수성능에 미치는 수직 액막 파동의 영향에 관한 연구)

  • 김정국;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-201
    • /
    • 2004
  • In the present study, the improvement of absorption characteristics on combined heat and mass transfer process in a falling film of a vertical absorber by change of geometric parameters were studied experimentally and analytically. The energy and diffusion equations are solved simultaneously to give the temperature and concentration variations at the liquid solution-refrigerant vapor interface and at the wall. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Effects of film Reynolds number, geometric parameters by insert device (spring) and flow pattern on heat and mass transfer performances have been also investigated. Especially, effects of the flow pattern by geometric parameters have been considered to observe the total heat and mass transfer rates through falling film along the absorber. As a numerical and experimental result, maximum absorption rate was shown at the wave-flow by insert device (spring). The error ranges between experiment and analysis were from 5.8 to 12% at Re$_{f}$ > 100.0.

A Numerical Model for Heat and Mass Transfer Processes within a Vertical Tube GAX Absorber (수직원관형 GAX 흡수기 내부의 열 및 물질전달과정에 대한 수치모델)

  • 천태식;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.102-111
    • /
    • 2000
  • A numerical model which simulates the simultaneous heat and mass transfer within a vertical tube GAX absorber was developed. The ammonia vapor and the solution liquid are in counter-current flow, and the hydronic fluid flows counter to the solution liquid. The film thickness and the velocity distribution of the liquid film were obtained by matching the shear stress at the liquid-vapor interface. Two-dimensional diffusion and energy equations were solved in the liquid film to give the temperature and concentration, and a modified Colburn-Drew analysis was used for the vapor phase to determine the heat and mass fluxes at the liquid-vapor interface. The model was applied to a GAX absorber to investigate the absorption rates, temperature and concentration profiles, and mass flow rates of liquid and vapor phases. It was shown that the mass flux of water was negligible compared with that of ammonia except the region near the liquid inlet. Ammonia absorption rate increases rapidly near the liquid inlet and decrease slowly. Both the absorption rate of ammonia vapor and the desorption rate of water near the liquid inlet increase as the vapor mass flow rate increases, but the mass fluxes of the ammonia and the water near the liquid outlet decrease as the mass flow rate of the vapor increases.

  • PDF