• Title/Summary/Keyword: energy FWHM

Search Result 163, Processing Time 0.03 seconds

Grain Size Analysis by Hot-Cooling Cycle Thermal Stress at Y-TZP Ceramics using Full Width at Half Maximum(FWHM) of X-ray Diffraction (X-ray 회절의 반치전폭(FWHM)을 이용한 Y-TZP세라믹스에서 반복 열응력에 의한 입계크기 분석)

  • Choi, Jinsam;Park, Kyu Yeol;Kong, Young-Min
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.264-270
    • /
    • 2019
  • As a case study on aspect ratio behavior, Kaolin, zeolite, $TiO_2$, pozzolan and diatomaceous earth minerals are investigated using wet milling with 0.3 pai media. The grinding process using small media of 0.3 pai is suitable for current work processing applications. Primary particles with average particle size distribution D50, ${\sim}6{\mu}m$ are shifted to submicron size, D50 ${\sim}0.6{\mu}m$, after grinding. Grinding of particles is characterized by various size parameters such as sphericity as geometric shape, equivalent diameter, and average particle size distribution. Herein, we systematically provide an overview of factors affecting the primary particle size reduction. Energy consumption for grinding is determined using classical grinding laws, including Rittinger's and Kick's laws. Submicron size is obtained at maximum frictional shear stress. Alterations in properties of wettability, heat resistance, thermal conductivity, and adhesion increase with increasing particle surface area. In the comparison of the aspect ratio of the submicron powder, the air heat conductivity and the total heat release amount increase 68 % and 2 times, respectively.

Uranium Enrichment Analysis with Gamma-ray Spectroscopy (FRAM을 이용한 우라늄 농축도 분석의 신뢰성 평가 연구)

  • Eom, Sung-Ho;Jeong, Hye-Kyun;Park, Jun-Sic;Park, Se-Hwan;Shin, Hee-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.16-23
    • /
    • 2011
  • Accurate measurement of uranium enrichment is very important in nuclear material accountability. The analysis uncertainty of the uranium enrichment measurement with gamma-ray analysis was studied in the present work. FRAM (Fixed energy Response function Analysis with Multiple efficiencies) code was used to determine the uranium enrichment. If the shield materials were placed between the detector and the sample, the error was measured and analyzed. Measurement time was varied and the dependency of the analysis uncertainty on the measurement time was studied. Transmitted gamma-ray intensities and FWHMs of the peaks in the energy spectrum were measured as the shield thickness was varied. The transmitted gamma-ray intensity follows shape of the exponential function, and the FWHM was almost independent of the shield thickness. The uncertainty of FRAM analysis was studied when the thick shield material was placed between the detector and the sample. Our work could be helpful in analysis of the fissile material in uranium sample.

The Compound Refractive Lens for Hard X-ray Focusing

  • Choi, J.;Jung, J.;Park, S.;Kwon, T.
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.76-81
    • /
    • 2007
  • The compound refractive X-ray lens (CRL) for focusing hard X-rays is investigated to determine the parameters such as the focal length, the focal spot size, and spatial distribution at the focal spot using a simple theoretical calculations and CRLs fabricated by the self-assembly method. The number of individual compound lenses are defined for the given focal length of 1 m. The X-ray energy of 1 to 40 keV is used in the calculations. The CRL for focusing hard X-rays which generated from the X-ray tube is fabricated by nanoparticle-polymer composite in the form of circular concaves. The self-assembly method is applied to form the nanoaluminum-poly (methly meth-acrylate) composite and carbon-polymer composite CRL lenses. Aluminum nanoparticles of 100 nm and carbon microparticles are diffused in the polymer solution then the high gravity up to 6000G is applied in it to form the concave lens shape. X-ray energy at 8 keV is used for characterization of the composite CRLs. The FWHM of intensity for the fabricated nanoaluminium composite CRL system, N=10 is measured as 1.8 mm, which would give about $70{\mu}m$ in FWHM at 1 m of the focal length.

광전도체 $ZnGa_2Se_4$ 박막의 전기적 특성

  • Hong, Gwang-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.381-381
    • /
    • 2010
  • From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the ZnGa2Se4singlecrystalthinfilm, wehavefoundthatthevaluesofspinorbitsplitting$\Delta$soandthecrystalfieldsplitting$\Delta$crwere251. 9meVand 183.2me Vat 10K, respectively. FromthephotolwninescencemeasurementontheZnGa2Se4singlecrystalthinfilm,weobservedfreeexcition(EX)existingonlyhighqualitycrystalandneutralboundexiciton(A0,X)havingverystrongpeakintensity.Then,thefull-width-at-half-maximum(FWHM)andbindingenergyofueutralacceptorboundexcitionwerel1meVand24.4meV,respectivity.ByHaynesrule,an activation energy of impurity was 122 meV.

  • PDF

Output Ccharacteristics of XeCl Excimer Laser Excited by Transeverse-Electron-Beam (횡방향 전자빔여기 XeCl 엑시머 레이저의 출력특성)

  • 류한용;이주희;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.386-393
    • /
    • 1994
  • We have investigated output characteristics of XeCI excimer laser excited by transeverse electronbeam. We used e-beam output of 880 kV, 21 kA (70 ns, FWHM) and controlled current density of e-beam by pulsed magnetic coil (4.7 kG) which was fabricated around an e-beam diode (A-K gap is 21 mm) and laser chamber. We have obtained 35 J (4 atm) of e-beam deposition energy injected into laser media. The deposition energy was converted from an exposure area of Radcolor film and rising pressure of gas media which is measured by pressure jump method. The excited volume of $320cm^{3}$ was calculated. The maximum efficiency of 1.7% was obtained with the mixing ratio of HCllXe/Ar==0.2/ 6.3/93.5% and total pressure of 3 atm. Also laser output energy and specific energy were obtained 0.52 J and 1.7 J/I, respectively. For the analysis of experimental results we have developed computer simulation code. From the good agreements with the results of experiment and simulation we could theoretically explain the XeCI* formation channel. relaxation channel, and absorption channel of 308 nm.308 nm.

  • PDF

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

A Study on Optics and Spectral Energy Distribution Characteristics of LEDs lamp (LED램프의 광학 및 분광분포 특성 연구)

  • Hwang, Myung-Keun;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.68-75
    • /
    • 2003
  • 본 논문에서는 파랑, 녹색, 호박색 빨강색, 백색 등 고휘도 5mm LED(light emitting diode)의 기본적인 분광분포(SED: spectral energy distribution) 특성을 분석하였으며, LED램프의 중요한 광학 특성인 광속, 효율 피크 파장$({\lambda}p)$, 가중치 평균 파장, 반치폭(FWHM, $\Delta\lambda$), 색도좌표, 주 파장, 자극순도(Pe)와 휘도순도(Pc) 등을 측정 및 실험하였다. 제시된 LED램프의 특성 데이터는 앞으로 LED램프를 사용한 새로운 조명등기구를 개발하는데 많은 도움을 줄 것이며, 이러한 측정 데이터들은 조명용 광원으로서 LED램프의 사용 대체 가능성을 나타낸다.

Emission and Structural Properties of Titanium Oxide Nanoparticles-coated a-plane (11-20) GaN by Spin Coating Method

  • Kim, Ji-Hoon;Son, Ji-Su;Baik, Kwang-Hyeon;Park, Jung-Ho;Hwang, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.146-146
    • /
    • 2011
  • The blue light emitting diode (LED) structure based on non-polar a-plane (11-20) GaN which was coated TiO2 nanoparticles using spin coating method was grown on r-plane (1-102) sapphire substrates to improve light extraction efficiency. We report on the emission and structural properties with temperature dependence of photoluminescence (PL) and x-ray rocking curves (XRC). From PL results at 13 K of undoped GaN samples, basal plane stacking fault (BSF) and near band edge (NBE) emission peak were observed at 3.434 eV and 3.484 eV, respectively. We also found the temperature-induced band-gap shrinkage, which was fitted well with empirical Varshini's equation. The PL intensity of TiO2 nanoparticles ?coated multiple quantum well (MQW) sample is decayed slower than that of no coating sample with increasing temperature. The anisotrophic strain and azimuth angle dependence in the films were shown from XRC results. The full width at half maximum (FWHM) along the GaN [11-20] and [1-100] directions were 564.9 arcsec and 490.8 arcsec, respectively. A small deviation of FWHM values at in-plane direction is attributed to uniform in-plane strain.

  • PDF

Comparison of SPECT Images with $^{99m}Tc$ Collimators ($^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향)

  • Lee, Man-Koo;Lee, Jeong-Ok;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF