• Title/Summary/Keyword: endurance test

Search Result 554, Processing Time 0.029 seconds

Prediction and Verification of Hover Performance through Multi-Copter Propulsion System Test Results (멀티콥터의 추진 시스템 실험 결과를 통한 제자리 비행 성능 예측 및 검증)

  • Park, Seungho;Go, Yeong-Ju;Ryi, Jaeha;Choi, Jong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.527-534
    • /
    • 2018
  • The endurance of the multi-copter is one of the important variables that determine the mission performance. Therefore, accurate endurance should be defined as essential for performing effective missions. In this paper, we present the results of the study on the flight performance of the aircraft, especially the hovering of the drone(multi-copter). Unlike conventional aircraft, which consider aerodynamic performance by the fuselage, the multi-copter is mostly determined by the propulsion system. Therefore, the research method classifies the various parts constituting the drone system into functions, analyzes the performance of the unit parts and obtains the experimental data by sorting out the specifications and functions at the component level and mathematical formulation, The results of this study are as follows. In addition, the 5kg class quad copter was used to predict and verify the voltage change with endurance through analysis of in situ flight. By predicting endurance under various conditions, it can help design/build the right Multi-copter for mission.

A Study on the Development of Low-Altitude and Long-Endurance Solar-Powered UAV from Korea Aerospace University (3) - Flight Test Results and Analysis of Solar Powered UAV - (한국항공대학교 저고도 장기체공 태양광 무인기 개발에 관한 연구 (3) - 태양광 무인기 비행실험 결과 및 분석 -)

  • Kim, Doyoung;Kim, Taerim;Jeong, Jaebaek;Park, Sanghyuk;Bae, Jae-Sung;Moon, Seokmin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.7
    • /
    • pp.489-496
    • /
    • 2022
  • This paper introduces the system for KAU-SPUAV, which is designed and developed by Korea Aerospace University, and verifies its performance through flight test. Specification of two versions of KAU-SPUAV, avionics system, and Ground Control System (GCS) are introduced. Three missions are performed with suggested UAVs: LTE signal mapping, circumnavigation of Jeju island seashore, and long endurance flight. Each mission consists of long distance and long endurance flight which takes advantage of KAU-SPUAV. Research team of KAU-SPUAV confirmed its versatility through suggested flight data. Also based on flight results, the team found the potential of performance improvement of KAU-SPUAV.

Development of Mechanical Face Seal in 75-tonf Turbopump for Leakage Reduction (누설 저감을 위한 75톤급 터보펌프 개량형 미케니컬 페이스실 개발)

  • Bae, JoonHwan;Kwak, Hyun-Duck;Lee, ChangHun;Choi, JongSoo
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • In this paper, we present an experimental investigation of the leakage and endurance performances of mechanical face seals in a 75-tonf turbopump for the Korea Space Launch Vehicle II first-stage engine. A mechanical face seal is used between the fuel pump and turbine to prevent mixing of the fuel and turbine gas. However, excessive leakage occurs through the carbon attached to the mechanical face seal bellows. To reduce this leakage, we redesign the mechanical face seal such that the contact area between the fuel and carbon is reduced, height of the carbon nose is reduced, and stiffness of the bellows is increased. Then, we conduct static and dynamic leakage tests and endurance tests to compare the performances of the original and modified mechanical face seals. The investigation of the leakage of the old and new mechanical face seals confirms that the leakage performance is significantly improved, by 80%, in the new design in comparison with the old design. The endurance tests demonstrate that the average wear rate of carbon in the new mechanical face seal is 0.1094 ㎛/s. The service lifetime is predicted to be 4,200 s, which is 28 times greater than the requirement. Finally, we present a new mechanical face seal in a 75-tonf turbopump, and perform a validation test in the real-propellant test facility at the NARO Space Center. Based on the test results, we can confirm that the modified mechanical face seal works well under real operating conditions.

Effect of pain on cranio-cervico-mandibular function and postural stability in people with temporomandibular joint disorders

  • Mehmet Micoogullari;Inci Yuksel;Salih Angin
    • The Korean Journal of Pain
    • /
    • v.37 no.2
    • /
    • pp.164-177
    • /
    • 2024
  • Background: Neck and jaw pain is common and is associated with jaw functional limitations, postural stability, muscular endurance, and proprioception. This study aimed to investigate the effect of jaw and neck pain on cranio-cervico-mandibular functions and postural stability in patients with temporomandibular joint disorders (TMJDs). Methods: Fifty-two patients with TMJDs were included and assessed using Fonseca's Questionnaire and the Helkimo Clinical Dysfunction Index. An isometric strength test was performed for the TMJ depressor and cervical muscles. The TMJ position sense (TMJPS) test and cervical joint position error test (CJPET) were employed for proprioception. Total sway degree was obtained for the assessment of postural stability. Deep neck flexor endurance (DNFE) was assessed using the craniocervical flexion test. The mandibular function impairment questionnaire (MFIQ) was employed to assess mandibular function, and the craniovertebral angle (CVA) was measured for forward head posture. Results: Jaw and neck pain negatively affected CVA (R2 = 0.130), TMJPS (R2 = 0.286), DNFE (R2 = 0.355), TMJ depressor (R2 = 0.145), cervical flexor (R2 = 0.144), and extensor (R2 = 0.148) muscle strength. Jaw and neck pain also positively affected CJPET for flexion (R2 = 0.116) and extension (R2 = 0.146), as well as total sway degree (R2 = 0.128) and MFIQ (R2 = 0.230). Conclusions: Patients with painful TMJDs, could have impaired muscle strength and proprioception of the TMJ and cervical region. The jaw and neck pain could also affect postural stability, and the endurance of deep neck flexors as well as mandibular functions in TMJDs.

Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor (원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험)

  • Choi, M.H.;Cho, M.S.;Choo, K.N.;Park, S.J.;Kim, B.G.;Kang, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

The Changes of Isokinetic Strength in Accordance with Short-term Weight loss of Wrestlers (레슬링 선수들의 단기간 체중감량이 슬관절의 등속성 운동능력에 미치는 영향)

  • 염종우
    • Journal of Life Science
    • /
    • v.12 no.6
    • /
    • pp.780-785
    • /
    • 2002
  • The purpose of this study is to investigate isokinetic strength changes of knee joint in accordance with short-term weight loss of wrestlers. For this purpose, 14 male wrestlers of a K technical high school in B city participated in our research. The wrestlers were divided into two groups; one group of the wrestlers didn't lose any weight, and the other lost over 5% of their weights. The isokinetic strength was also observed before and after weight loss. The isokinetic strenght test were processed at test speed of the$60^{\circ}C$/sec, $90^{\circ}C$/sec, and $250^{\circ}C$/sec with the CYBEX NORM system(Cybex 770+TMS, USA). Peak torque, peak torque %BW, total work, total work %BW, and endurance ratio were measured. Results showed that the isokinetic strength after the short-term weight loss of wrestlers decreased meaningfully Although endurance ratio didn't show any meaningful difference in our research, but more accurate research may find out the relationship between short-term weight loss and the endurance ratio of isokinetic strength.

Comparing Persons with Neck Pain Experience to Persons without Neck Pain Experience in Deep Neck Muscle Size Using Ultrasonography Images and Neck Muscle Endurance Time (목통경험 유무에 따른 초음파 영상에서 측정된 심부 목근육 크기와 근지구력 시간에 대한 비교 연구)

  • Kwon, Mi-Seong;Jeon, Hye-Ran;Lee, Hae-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.326-334
    • /
    • 2011
  • The aim of the study was to investigate the thickness of deep neck muscles during neck endurance tests using ultrasonography images to assess muscle sizes in persons with or without neck pain experience. Sixty-five university students volunteered for the study. The thicknesses of longus colli, longus capitis, semispinalis and cervical multifidus were assessed bilaterally using diagnostic ultrasound equipment during each endurance test. Participants were divided into two groups based on their Neck Pain(NP) experience; 45 subjects of those had no experience of NP (Group1) whereas 20 subjects of those reported NP experience sometime in their lives (Group2). Endurance time of both neck flexion and extension tests in Group1 showed significantly longer than Group's (p<0.01). The thicknesses of deep neck flexors and extensors were observed smallest at the terminal of endurance tests in general. Only left longus colli was found to be significantly smaller at rest in subjects of Group2 than Group 1's (P=0.02). The size difference between at contraction and the terminal of right longus capitis was observed bigger in subjects of group1 than subjects in group2. Future studies are needed to conduct with clinical subjects to assess contraction patterns of neck muscles.

A Study of Related Factors in the Bone Mineral Density of the Institutionalized Elderly (시설노인의 골다공증 관련요인 연구)

  • Kim, Hee-Ja
    • Research in Community and Public Health Nursing
    • /
    • v.8 no.1
    • /
    • pp.31-44
    • /
    • 1997
  • The purpose of this study was to measure and determine the relationship of femoral neck and lumbar bone mineral density with their and related factors. It were measured and determined the relationships among bone mineral density, bone mineral content in the lumbar and femoral neck, muscle strength (arm, back, leg), muscle endurance, instrumental activity of daily living (IADL), quality of life, cognitive perceptual variables(self efficacy, perceived health status), age, age at menopausal period. The twenty five subjects participating in this study consisted of twelve males and thirteen females at a C-institution in Chung Buk province. The mean age of subjects was 73.64 years. The data was collected from August, 1993 to September, 1993. The data was analyzed with $x^2-test$, t-test, Correlation, multiple regression using a SPSS pc+ program. 1. The mean femoral neck bone mineral density was $0.636g/cm^2$, 66.7% of young bone mineral density, the mean lumbar($L_2-L_4$) bone mineral density was $0.807g/cm^2$, 79.86% of young bone mineral density. The mean fermoral neck bone mineral content was 2.906g and the mean lumbar bone mineral content was 36.898g. 2. The mean muscle strength was 17.14kg(grip strength), 32.05kg(back lift strength), 17.14kg (leg lift strength) and the mean muscle endurance was 9.92times. 3. Men showed a significantly higher score (p<0.01) in muscle strength and muscle endurance than women, as well as a significantly higher score on self efficacy and perceived health status(p<0.05). 4. The femur neck bone mineral density had a significant correlation(p<0.0l) with leg lift strength, back lift strength, and their was a significant correlations (p<0.05) with arm strength and muscle endurance. Lumbar ($L_2-L_2$) bone mineral density had a significant correlation(p<0.05) with muscle endurance, grip strength and IADL. 5. With the multiple regression analysis the most significant predictor for lumbar bone mineral density were IADL, the most significant predictor for femoral neck bone mineral density was leg strength. This study concluded: As the mean bone mineral density and bone mineral content were low, the aged showed osteopenia. Bone mineral density, muscle strength and IADL were correlated. The aged could pro mote muscle strength, bone mineral density and IADL through Leg Press exercise which was safe and efficient for the aged. This Leg Press exercise contributed to prevention of osteoporosis and promoted the health of the aged.

  • PDF

Testing for validity of isometric muscle endurance test as an abdominal muscular endurance evaluation methods (복근 지구력 평가 도구로서 등척성 수축 후 버티기 방법의 타당성 비교 검증)

  • Park, Soon-Tae;Hur, Sung-Hoon;Lee, Jang-Kyu;Lee, Jong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.815-827
    • /
    • 2014
  • The current study was undertaken to verify appropriateness of muscle endurance test at three different angles ($30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$) of isometric contraction position, and to sought valid and reliable testing method that provide an alternative to sit-ups. Total 92 young and healthy subjects (68 males and 24 females) were recruited, and the following results were obtained. 1. A low correlations in males, but a high correlations in females was found when the comparisons were made between aerobic and muscle endurance capability. 2. Measuring tolerance time, by using isometric contraction was showed a significant correlation with the repetition numbers of sit-ups. 3. The highest correlation was found at 40 inclined degrees of plane, and the lowest correlation was drawn from 50 inclined degrees of plane. Based on these results, it was concluded that measuring tolerance time during maintaining an isometric contraction at 40 inclined degrees of plane is a valid and effective tool for measuring abdominal muscle endurance, and it can be used as an alternative way of sit-up, which potentially risky for inducing many back-associated injuries. Further studies need to be undertaken to determine for optimal angles, that can safely be applied for people of various age groups and physical conditions.

Synthesis of WS$_2$ Solid Lubricant and Its Application to the Ball Bearing (WS$_2$ 고체윤활제의 합성 및 구름베어링 적용)

  • 신동우;윤대현;최인혁;김경도
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.173-179
    • /
    • 1998
  • The processing conditions for the synthesis of platelet WS$_2$ lubricant powder through the solid-gas reaction were optimized. The tungsten and sulfur powders were sealed in a vacuum of 10$^{-6}$ torr, prior to heat-treating at 850$\circ$C for 8 days. The react~on product showed the well-developed platelet WS$_2$ powder with an average size of 3.8 $\mu$m. The synthesized WS$_2$ powder was coated on the commercial deep grooved ball bearing (No. 6203) to examine the effects of WS$_2$ coating layer on the noise and endurance of the ball bearing. The level of noise obtained from WS$_2$ coated-ball bearing was higher (56 dB) than the value occurred in the case of greece (37 dB). The life-time of the ball-bearing assembled after coating WS$_2$ powder increased 50 times compared to the non-coated bali-bearing.

  • PDF