• 제목/요약/키워드: end-point temperature

검색결과 141건 처리시간 0.028초

Temperature Effect on the Configurational Properties of an n-Decane Chain in Solution

  • Oh, In-Joon;Ree, Tai-Kyue
    • Bulletin of the Korean Chemical Society
    • /
    • 제5권4호
    • /
    • pp.162-167
    • /
    • 1984
  • Equilibrium and dynamical behaviors of an n-alkane poymer (decane) in solution have been investigated by a molecuar dynamics simulation method. The polymer is assumed to be a chain of elements $(CH_2)$ interconnected by bonds having a fixed bond length and bond angle, but esch bond of the polymer is allowed to execute hindered internal rotation. The calculation explicitly considers the molecular naturer of solvent by including the intermolecular interactions between slovent-solvent molecules and chain element-solvent molecule. We present the results of calculations on (1) equilibrium properties (the solvent molecule-chain element pair correlation function, chain element-chain element pair correlation function, the mean square end-to-end distance and the mean square radius of gyration of the polymer) and (2) dynamic properties (four different autocorrelation functions, namely, the autocorrelation functions for the end-to-end distance and the radius of gyration, and the velocity autocorrelation functions for the center of mass and the end point of the chain). We found that the physical properties of the polymer chain depends sensitively on temperature. Comparison of the present work with other authors' results is also presented.

Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs

  • Park, Hwan-Hyung;Jung, Suk-Hwan;Yoon, Juil;Jee, Kwang Koo;Han, Jun Hyun;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.214-221
    • /
    • 2019
  • Objective: To investigate the effects of reversing the coiling direction of nickel-titanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber ($37{\pm}1^{\circ}C$). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

소아에서의 저체온 심폐바이패스후 재가온 종료온도와 후하강 (End Point Temperature of Rewarming and Afterdrop After Hypothermic Cardiopulmonary Bypass in Pediatric Patients)

  • 김원곤;이해원;임청
    • Journal of Chest Surgery
    • /
    • 제30권2호
    • /
    • pp.125-130
    • /
    • 1997
  • 저체온 심폐바이패스후에 환자를 적절히 재가온시키지 못하면 수술직후 중환자실에서 종종 후하강 (afterdrop)현상이 발생할 수있다. 후하강이 생기면 전해질 장애, 부정맥, 혈역학적 불안정을 일으킬 수 있을뿐 아니라 전율에 의해 산소소모량을 크게 증가시킴으로서 수술 직후 불안정한 심근에 악영향을 미칠 수 있다. 따라서 본 연구는 소아 심장수술환자에서 적정 재가온 종료 온도를 찾기 위한 노력의 일환으로 50명의 환자들을 직장 온도를 기준으로 섭씨 35.5도에서 재가온을 종료한 군과 37도에서 재가온을 종료한 군으로 나눈뒤 두 군 사이에 후하강의 발생 여부를 비교 분석하였다. 그리고 후하강의 여부와 함께 심박수, 수축기 및 확장기 혈압 등 활력 증후도 함께 측정하였다. 그밖에 체온측정 장소에 따른 온도 의 차이를 관찰하기 위 해 심폐바이패스 중에는 직장 온도와 함께 식도 온도를 그리고 중환실에서는 직장 온도와 함께 액와 온도를 각각 측정하였다. 환자들은 전례에서 롤러 펌프에 의한 비박동성 관류를 시행 받았으며 산화기로는 막형 또는 기포형 산화기가 사용되었다. 두군의 환자들은 연령, 성별, 체표면적, 심폐바이패스 시간, 재가온 시간 등에서 유의한 차이가 없었다. 관찰 결과 두군의 환자들에서 모두 회복실에 도착한후 16시간후 까지 측정한 직장 온도에서 후하강은 없었으며 두군간 시간대별 직장 체온의 차이도 관찰되지 않았다. 두군간 심박수와 수축기 및 확장기 혈압에서도 유의한 차이는 발견되지 않았다. 그리고 재가온 종료시 식도 온도는 직장 온도에 비해 높게 측정되었으며 중환자실에서 측정한 액와 온도는 직장 온도보다 항상 낮게 측정되었다. 전율은 전례에서 관찰되지 않았다. 결론적으로 본 실험 결과는 소아에서는 직장 온도를 기준으로 적어도 섭씨 35.5도 이상에서 재가온을 종료하면 후하강이 일어나기 어렵다는 것을 의미하고 있다. 8례(11%),술후 일과성 신경학적 합병증이 7례 (9%),술후 일과성 정신과적 합병증이 6례 (8%), 급성 신부전이 3례 (4%),술후 출혈 및 폐렴이 각각 2례 (3%), 창상 감염과 십이지장 궤양 천공이 각각 1례 (1 %)이었다. 역행성심정 지액을 이용한 심근 보호법은 고위험도의 허혈성 심질환 환자에서의 관상동맥 우회술에서 수술 위험도를 최소화할 수 있는 유용한 심근 보호법이라고 생각된다.처리구를 무작위로 할당하여 배양하였으며, 또한 740개의 정상수정란도 같은 반복수로 배양을 실시하였다. 미세주입한 수정란은 8일 후 11.6%(26/255) 및 5.2% (14/267)가 대조구 및 G418 처리구에서 배반포기까지 발달하였으며 정상수정란은 27.2% (151/740)가 배반포기 배까지 발달하였다. 미세주입후 대조구에서는 23.1$\pm$2.6/70.7$\pm$4.7 (32.7%)의 할구가 $\beta$-Gal 활력을 보였고, 반면에 100$\mu\textrm{g}$/ml G418 처리구에서는 40.3$\pm$4.1/48.8$\pm$7.5 (82.6%)가 $\beta$-Gal 활력을 보였다. 비록 mosaic 형태로 외래유전자가 발현되었지만 대조구에서 87.0% (26/30개) 배반포기가 $\beta$-Gal 활력을 보인 반면, G418 처리구에서는 모든 배반포기가 $\beta$-Gal 활력을 보였다 (P<0.05). 그러나 대조구 및 G418 처리구의 ICM colony에서는 영양배엽과 내배엽을 제외한 epiblast에서는 확인되지 않았다. 그러나 이 결과로부터 $\beta$-actin promoter/lacZ gene이

  • PDF

일본잎갈나무 정각재(正角材)의 고온건조(高溫乾燥) 온도(溫度)가 내부온도(內部溫度), 건조속도(乾燥速度) 및 건조결함(乾燥缺陷)에 미치는 영향(影響) (Effects of Drying Temperature on Internal Temperature, Drying Rate and Drying Defects for Japanese Larch in High-Temperature Drying)

  • 이준호;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권4호
    • /
    • pp.99-107
    • /
    • 1997
  • This study was executed to test the possibility of replacement for domestic Japanese larch(Larix leptolepis) for hardwoods and to acquire the information about the effects of drying temperature on internal temperature, moisture content and drying defects. In high-temperature drying, internal temperature increased rapidly to boiling point, immediately after that point the internal temperature rising rate was reduced. In the case of drying at temperature of $125^{\circ}C$, internal temperature could reach at boiling point in a very short time. Moisture content in high-temperature drying showed constant drying rate period and first period of falling rate drying together in 4 hours since experiment begun. There was no strong correlation between initial moisture content and final moisture content. Average drying rate at $115^{\circ}C$, $120^{\circ}C$ and $125^{\circ}C$ was 1.42%/hr, 1.88%/hr and 2.02%/hr, respectively; the case of drying temperature of $125^{\circ}C$ showed most rapid drying rate. Drying rate of $125^{\circ}C$ was so rapid that it showed more severe shrinkage, bow, collapse, end check, and internal check development than in other drying conditions. The result of this study showed the strong possibility of high-temperature drying for Japanese larch, and to dry Japanese larch optimally, dry bulb temperature should not exceed $120^{\circ}C$.

  • PDF

여름철 포도 수확 작업 농민의 작업 환경 및 노동 부담 평가 (Evaluation of Farmer's Workload and Thermal Environment During Harvesting Grape in Summer)

  • 최정화;김명주;이주영
    • 대한가정학회지
    • /
    • 제40권11호
    • /
    • pp.193-205
    • /
    • 2002
  • To evaluate farmers' workload during harvesting grapes in summer, this study investigated farmers' physiological, psychological responses, work postures and thermal environment around in the field. This field study was conducted in the Anseong County of Kyonggi Province at the end of August. Five career farmers (1 male, 4 females) volunteered as subjects. Three of them were over their sixties. During harvesting grapes in the field, physiological responses were monitored continuously. 1. Air temperature (T/sub a/), air humidity(H/sub a/), black globe temperature(T/sub g/), air velocity and WBGT around the grape field were 26.9℃, 77.7%RH, 32.8℃, 0.08㎧ and 26.3℃, respectively. Because farmers started the harvesting task in early morning, thermal environments weren't conditions to give farmers severe heat strain. 2. The percentage of the work postures was larger in order of standing, walking, and bending one's back posture. Particularly, the percentage of standing posture with raising both arms above shoulder of two farmers was up to 29% and 61% of the total work duration. 3. Rectal temperature (T/sub re/), mean skin temperature (T/sub sk/), clothing microclimate temperature (T/sub cl/) on the chest and the back, heart rate (HR) and energy expenditure (EE) were 37.2℃, 33.1℃, 32.0℃, 32.4℃, 88bpm and 1.3 Kca1/㎡/min respectively. In the point of these physiological results, we evaluated that the harvesting task was a moderate work. 4. All farmers expressed‘hard, hot, humid and slightly uncomfortable’ at the end of works for each subjective questionnaire. The grape harvesting tasks were not evaluated as a very hard work in the point of physiological work standards. But we considered 1) inappropriate work posture (standing posture with raising both arms above shoulder) and 2) farmers' age as burden factors. These findings suggest that adding adequate protective clothing/equipments for farmers may contribute to maintain their body temperature within the normal range, stabilize HR and decrease psychological strain.

고온 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성에 관한 수치적 모사 (Numerical Simulation on the Heat Transfer Characteristics of a Solar Thermal Receiver Depending on the End-Wall Angle Variation)

  • 정의국;부준홍;강용혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2100-2105
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a high-temperature, high heat flux solar receiver as the end-wall angle varied. The concentration ratio of the solar receiver ranges from 200 to 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver incorporating high-temperature sodium heat pipe as well as a typical one that employs a molten-salt circulation loop with the same outer dimensions. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. FLUENT, a commercial software, was employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels and heat pipes. The numerical results were compared and analyzed from the view point of heat transfer characteristics the solar receiver system.

  • PDF

Vortex Tube의 냉출구 Orifice에 관한 실험적 연구 (An experimental study for cold end orifice of vortex tube)

  • 유갑종;최병철
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1061-1073
    • /
    • 1996
  • Vortex tube is a simple device which splits a compressed gas stream into a cold stream and a hot stream without any chemical reactions. The phenomena of energy separation taking place in a vortex tube has been investigated experimentally. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner of special purpose. In this study, experimental study on vortex tube efficiency was performed with various cold end orifices and nozzles type. The experimental results indicate that there is an optimum diameter of cold end orifice and nozzle type for the best cooling performance. The variation of the maximum wall temperature along the vortex tube surface provides useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. The similarity relation for the prediction of the temperature of the cold exit air was obtained.

변수화 반도체 모델을 이용한 Cubic Zinc-blonde CdSe의 유전함수 분석 (Dielectric Function Analysis of Cubic CdSe Using Parametric Semiconductor Model)

  • 정용우;공태호;이선영;김영동
    • 한국진공학회지
    • /
    • 제16권1호
    • /
    • pp.40-45
    • /
    • 2007
  • 본 연구에서는 광전자 소자에 폭넓게 사용되는 ZnCdSe 화합물 반도체의 end-point인 CdSe의 유전함수 spectrum을 Vacuum Ultra Violet spectroscopic ellipsometry(타원편광분석법) 측정하여 분석하였다. 측정 결과는 변수화 모델을 이용하여 분석하였으며 그 결과 6 eV 이상에 존재하는 전자전이점들을 확인할 수 있었고 CdSe의 Critical Point(CP) 구조를 수치화 함으로써 온도나 화합물 함량에 따른 광특성 의존성 연구 등에 활용될 수 있는 database를 확보하였다.

Effect of Flavors on the Viscosity and Gelling Point of Aqueous Poloxamer Solution

  • Rhee, Yun-Seok;Shin, Young-Hee;Park, Chun-Woong;Chi, Sang-Cheol;Park, Eun-Seok
    • Archives of Pharmacal Research
    • /
    • 제29권12호
    • /
    • pp.1171-1178
    • /
    • 2006
  • This study examined the effects of flavors, which are usually added to improve the appeal of pharmaceutical agents, on the viscosity and gelling point of 18% (w/w) aqueous poloxamer 407 solutions. Monoterpenes, esters, alcohols, aldehyde ketones and lactone type flavors were examined. The concentrations of flavor ranged from 0.1 to 1.0%(w/w). After adding a flavor to the aqueous poloxamer 407 solution, the viscosity of the solution was measured using a Brookfield viscometer, and the gelling point was determined from the viscosity vs. temperature plot. The gelling point of the aqueous poloxamer 407 solution decreased with increasing concentration of flavors except for coumarin, vanillin and ethylvanillin. Thermal analysis with DSC showed an interaction between the flavors and poloxamer 407. These results suggest that the flavors bind to the hydrophilic end chains of poloxamer 407, which increases the viscosity, causing gelation at lower temperatures.

유한요소법을 이용한 정방형 밀폐용기내의 플란틀수가 낮은 유체의 자연대류에 관한 연구 (Finite Element Analysis of Natural Convection of Fluids with Low Prandtl Number in a Square Enclosure)

  • 김무현;이진호;강신형;손영석
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.541-550
    • /
    • 1988
  • 본 연구에서는 수평경계면이 단열이고 수직경계면이 서로 다른 온도로 유지되 고 있는 정방형밀폐용기내의 자연대류에 관해 유동함수-와도모델을 이용한 유한요소법 을 통해 특히 낮은 Prandtl수의 영향에 중점을 두어 경계층흐름이 존재할 때의 유동 및 열전달특성을 조사하였다.