• 제목/요약/키워드: end to end capacity

검색결과 1,028건 처리시간 0.028초

MIMO Two-way Cooperative Relay to Improve End to End Capacity in Non-equidistant Topology

  • ;강철규;오창헌
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.465-467
    • /
    • 2010
  • This paper proposes MIMO two-way cooperative relay scheme to optimize the end to end capacity in wireless multi-hop mesh network. The basic idea is to perform data transmission via multi-hop relay nodes, in equidistant topology, this method is quite efficient. However, on one hand this topology is very rare in practical situation, on the other hand, in real practical situation where the topology is most likely non equidistant, the end to end capacity significantly degrades due to bottleneck link caused by uneven SNR. Moreover, the end to end capacity degrades at high SNR due to overreach interference from far nodes existing in multi-hop relay networks. In this paper, MIMO two-way cooperative relay in the region of non equidistant nodes is found efficient to improve the end to end capacity. The proposed scheme is validated using numerical simulation.

  • PDF

비보강 확장단부판 접합부의 에너지소산능력 평가 (Evaluation of the Energy Dissipation Capacity of an Unstiffened Extended End-plate Connection)

  • 이수권;양재근
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2015
  • 확장단부판(extended end-plate) 접합부는 보-기둥 모멘트 접합부의 한 형태로 접합부를 구성하는 단부판(end-plate)의 두께 및 길이, 고장력볼트의 개수 및 직경, 고장력볼트의 게이지 거리, 용접부의 치수 및 길이 등에 따라서 상이한 거동특성과 에너지소산능력을 발현한다. 이러한 확장단부판(extended end-plate)는 미국 및 유럽 등지에서는 다양한 기하학적 형상으로 기둥-보 접합부에 적용되고 있다. 그러나 현재 우리나라에서는 강구조 보-기둥 접합부에 적극적으로 적용되고 있지 못한 상황이다. 이렇게 적용성이 높지 않은 이유로는 기하학적 형상변화에 따른 설계강도식 제안, 에너지소산능력 평가 및 시공지침의 제공이 적절하게 이루어지지 못하고 있기 때문이다. 따라서 이 연구에서는 단부판(end-plate) 두께가 상대적으로 얇은 기하학적 형상을 갖는 비보강 확장단부판(unstiffened extended end-plate) 접합부의 에너지소산능력을 평가하여 에너지소산능력 예측모델을 제안하기 위한 기초자료를 제공하기 위하여 진행하였다. 이를 위하여 비보강 확장단부판(unstiffened extended end-plate) 접합부에 대한 3차원 비선형 유한요소해석을 단부판(end-plate)의 두께를 변수로 하여 수행하였다.

Ultimate behaviour and rotation capacity of stainless steel end-plate connections

  • Song, Yuchen;Uy, Brian;Li, Dongxu;Wang, Jia
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.569-590
    • /
    • 2022
  • This paper presents a combined experimental and numerical study on stainless steel end-plate connections, with an emphasis placed on their ultimate behaviour and rotation capacity. In the experimental phase, six connection specimens made of austenitic and lean duplex stainless steels are tested under monotonic loads. The tests are specifically designed to examine the close-to-failure behaviour of the connections at large deformations. It is observed that the rotation capacity is closely related to fractures of the stainless steel bolts and end-plates. In the numerical phase, an advanced finite element model suitable for fracture simulation is developed. The incorporated constitutive and fracture models are calibrated based on the material tests of stainless steel bolts and plates. The developed finite element model exhibits a satisfactory accuracy in predicting the close-to-failure behaviour of the tested connections. Finally, the moment resistance and rotation capacity of stainless steel end-plate connections are assessed based on the experimental tests and numerical analyses.

가변선단재하판을 이용한 양방향말뚝재하시험의 치수 효과 (A Scale-Effect of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.884-890
    • /
    • 2009
  • The bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of the bi-direction can be known by using the loading of the end plate and two step procedures. The first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell, operated with end plate of 3 type on sand layer according to the relative density, loose, medium and dense conditions.

  • PDF

Experimental investigation on the shear capacity of RC dapped end beams and design recommendations

  • Wang, Quanfeng;Guo, Zixiong;Hoogenboom, Pierre C.J.
    • Structural Engineering and Mechanics
    • /
    • 제21권2호
    • /
    • pp.221-235
    • /
    • 2005
  • In this paper, the shear resistance behaviour of reinforced concrete (RC) dapped end beams is investigated by 24 tests until failure load. The main parameters considered are the dapped end height, the type and effective range to provided the stirrups and the bent form of the longitudinal reinforcement. The failure behaviour of dapped end beams is presented and some conclusions are given. Inclined stirrups and longitudinal bent reinforcement have more influence on the shear capacity than vertical stirrups. Additionally, the shear mechanism of dapped end beams is analysed. Relatively simple semi-empirical equations for shear strength have been derived based on the results of 22 dapped end beams. The predicted results are in close agreement with the experimental ones. Finally, some design suggestions for the ultimate shear strength of dapped end beams are presented.

선단유압재하시험을 이용한 단층파쇄대에 설치된 대구경 현장타설말뚝의 선단지지력 측정 사례 (Case Studiy on Measurement of End Bearing Capacity for Large Diameter Drilled Shaft Constructed in Fault Zone using Loading Test)

  • 정창규;김태훈;정성민;황근배;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.74-81
    • /
    • 2004
  • In this study, static end loading tests with load transfer measurement were accomplished for large diameter drilled shaft constructed in fault zone. Yield pile capacity (or ultimate pile capacity) from load-settlement curve was determined and axial load transfer behavior was measurd. The end bearing capacity was increased 2 times due to grouting the toe ground under pile base.

  • PDF

정확한 고정대역폭 추정을 통한 새로운 가용대역폭 측정 기법 (A New Available Bandwidth Measurement Technique with Accurate Capacity Estimation)

  • 조성호;최한;김종권
    • 한국정보과학회논문지:정보통신
    • /
    • 제32권4호
    • /
    • pp.495-507
    • /
    • 2005
  • 인터넷에서 단대단 (end-to-end) 가용대역폭 측정은 분산된 응용 서비스, 단대단 QoS 보장 등에 유용하게 이용할 수 있다. 일반적으로 단대단 가용대역폭 측정에는 단일-홉 갭 모델에 기반한 패킷 트레인 (packet train) 전송을 통한 측정이 많이 사용되고 있다. 하지만 패킷 트레인의 출력 간격은 네트워크 망 구성과 경쟁 트래픽에 의해서 영향을 받으므로, 이 때 발생한 오차에 의해서 가용대역폭 측정에도 오차가 발생하게 된다. 본 논문에서는 기존의 방법들이 가지고 있는 연이은 (bach-to-back) 패킷 트레인을 전송하여 링크의 고정대역폭을 측정에 의한 부정확성을 해결하기 위해서 패킷 트레인의 초기 갭에 영향을 받지 않는 가용대역폭 측정 알고리즘을 제안한다 또한 빠른 측정을 위해서 패킷 트레인 전송 시 적절한 초기 간격을 예측하는 방법을 제안한다. 제안하는 방법의 성능을 검증하기 위해서 다양한 망구조에서 실험을 통해서 기존의 기법들과 비교하였다.

SPT-N값에 따른 매입말뚝의 선단지지력 특성 연구 (Study on the Evaluation of End Bearing Capacity of Pre-Bored Piles for the SPT-N value)

  • 서동남;최상호;김진식;김성철;이동현;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2020
  • The equation of end bearing capacity is applied differently depending on the type of pile, construction method, and load characteristics considering the construction standards. The bearing capacity equation of the design standard is presented in various ways according to the design conditions such as construction method and ground condition, etc. but, It does not reflect the ground strength according to the SPT-N value of weathered rock. This study analyzed the trend of allowable tip bearing capacity by pile diameter through about 480 dynamic loading tests conducted for the construction/quality management of piles for the last 6 years since 2015. The equation for the ultimate end bearing capacity per unit area according to the SPT-N value is presented. The proposed formula of ultimate end bearing capacity per unit area can be applied in the range of 15,000kN/m2 to 30,000kN/m2. The proposed formula, which complements the existing formula, enables pile design and construction/quality management.

  • PDF

Tensile capacity of mortar-filled rectangular tube with various connection details

  • Kim, Chul-Goo;Kang, Su-Min;Eom, Tae-Sung;Baek, Jang-Woon
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.339-351
    • /
    • 2022
  • A mortar-filled rectangular hollow structural section (RHS) can increase a structural section property as well as a compressive buckling capacity of a RHS member. In this study, the tensile performance of newly developed mortar-filled RHS members was experimentally evaluated with various connection details. The major test parameters were the type of end connections, the thickness of cap plates and shear plates, the use of stud bolts, and penetrating bars. The test results showed that the welded T-end connection experienced a brittle weld fracture at the welded connection, whereas the tensile performance of the T-end connection was improved by additional stud bolts inserted into the mortar within the RHS tube. For the end connection using shear plates and penetrating stud bolts, ductile behavior of the RHS tube was achieved after yielding. The penetrating bars increased load carrying capacity of the RHS. Based on the analysis of the load transfer mechanism, the current design code and test results were compared to evaluate the tensile capacity of the RHS tube according to the connection details. Design considerations for the connections of the mortar-filled RHS tubes were also recommended.

선단지지된 항타개단강관말뚝의 축하중전이거동 (Axial Load Transfer Behavior for Driven Open-ended End bearing Steel Pipe Pile)

  • 임태경;정성민;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement were accomplished in the field. Yield pile capacity (or ultimate pile capacity) determined by load-settlement-time relationship was determined and axial load transfer behavior was analyzed. In the test for the four test piles were behaved as end bearing pile but ratios of skin friction to total pile capacity were 27%∼33%.

  • PDF