• Title/Summary/Keyword: end test

Search Result 3,059, Processing Time 0.036 seconds

An evaluation on 100,000km endurance test for the Korean EMU (표준전동차 10만km 내구도 시험평가)

  • 정종덕;김원경;한석윤;이호용;안태기;한성호
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.336-343
    • /
    • 2002
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. But endurance test come to an end well without severe problem. Hereafter, Korean EMU will be applied the quality certification of railroad supplies as a testing vehicle and their components will be applied in a new line.

  • PDF

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

Stress Change Varying with Hole Place of RC Column (유공위치 변경에 따른 RC기둥의 내력변화에 관한 실험적 연구)

  • Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.70-79
    • /
    • 2006
  • many plumbing system are needed in the ceiling of the building as it becomes advanced more and more. This leads to make effective space between ceiling level and slab less. Also, piping system is not suitably arranged and operated if it is bent around the columns which they are a lot. But this system can be more effective if it passes through the columns directly. Most people think that those columns should not be damaged with such as holes. But actually this is existed in a hotel building in switzerland. This study is to fing out how much capacity the columns become damaged and low using model size of $20cm{\times}30cm$ rectangular section, and 160cm long, in the structural test. it's compressive strength is focused on $240kg/cm^{2}$ design strength, commonly used in korea. Compressive test for them was done at Hanyang University using UTM one thousand tone(1000t) capacity. Variable numbers for the study are one hole of dia 3cm with distance 20cm or 40cm, two holes of dia 3cm with 20cm and 40cm distance, one hole of dia 5cm with distance 20cm and 40cm, two holes of dia 5cm with 20cm and 40cm distance, me eccentric hole with 20cm and 40cm distance, Normal(without hole). two test specimens of each variable are made for the test. ED5H20 capacity was 16.7% decreased, compared to normal one. While ED5H40 distant 40cm from the end of column top showed 19.5% capacity decrease, compared to normal one. Strain of ED5H20 diameter 5cm, in distance of 20cm form the top of the column was less 5% than the one of diameter 3cm. Finally, conclusions are that in case of hole diameter 3cm, located at 20cm from the end of the column top, capacity was decreased down to 3, percent only compared to the same diameter hole with 20cm distant from the end of it.

An Evaluation of Lap Splice Length of Epoxy Coated Reinforcements Using Beam-End Test (보-단부 시험을 이용한 에폭시 도막 철근의 겹침 이음길이 평가)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.175-182
    • /
    • 2020
  • The application of epoxy coated reinforcements is increased as a means to prevent a corrosion of reinforcements embedded in reinforced concrete structures, However, epoxy coating may reduce the bond capacity between concrete and reinforcement, which results a longer development length and lap splice length. This paper aims to the possibility of modification in lap splice length from reduction of basic development length which was confirmed using a direct pull out test. Total 36 beam specimens were tested to compare the lap splice properties of normal and epoxy coated reinforcements with beam-end test for various lap lengths and diameters of reinforcements. According to the results on failure modes, deformations, and crack widths of this experiments, the modification factor of 1.2 should be used, though the direct bond capacity is assured through direct pull out test.

Analysis of Bearing Capacity of Rock Socketed Pre-Bored Super Strength Piles Based on Dynamic Load Test Results (동재하시험을 통한 선단이 암반에 근입된 초고강도 매입 PHC 말뚝의 지지력 특성 분석)

  • Kim, Rakhyun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.89-100
    • /
    • 2019
  • The purpose of this study is to analyze the characteristics of bearing capacity of pre-bored super strength PHC (SSPHC) piles socketed in rocks based on dynamic load test results. Because the SSPHC piles have high compressive concrete strengths compared with those of regular high strength PHC piles, the allowable structural strengths of the SSPHC piles were increased. For optimal design of the super strength PHC piles, the geotechnical bearing capacity of the SSPHC piles should also increased to balance the increased allowable structural strength of the SSPHC piles. Current practices of pile installation apply the same amount of driving energy on both SSPHC and high strength PHC piles. As results of analyzing factors that influence bearing strength of SSPHC piles using dynamic load test, there was no relationship between SPT-N value at pile toe and end bearing capacity. But driving energy effects on end bearing capacity. In case of skin friction, driving energy had no effects. And reasonable method verifying design bearing strength is necessary because end bearing capacity is not considered sufficiently in restrike test results.

The Relationship between Optimal End-of-Life Care and Well Dying of Nurses (간호사의 최상의 임종간호 및 웰다잉 관계 연구)

  • Hyun, Woo-In;Kim, Miyoung
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.8
    • /
    • pp.628-639
    • /
    • 2022
  • The purpose of this study was to investigate the relationship between the optimal end-of-life care and well-dying perceived by nurses to provide the optimal end-of-life care for patients and their families. This subjects of the study were 121 nurses working in the ward or intensive care unit of a general hospital in Seoul, and the data collected from April 28 to May 12, 2021 were analyzed. Data were analyzed using t-test, ANOVA, and Pearson correlation coefficients with the SPSS/WIN 27.0 program. The total average of the subjects' perceptions of the optimal end-of-life care was 4.04±0.82 on a five-point scale, indicating the overall level of 'agree' with the optimal end-of-life care. The total average of well dying perceived by the subjects was 3.63±1.14 on a five-point scale, and the most important recognized questions was to die peacefully. Of general characteristics, there was a significant differences on optimal end-of-life care according to age (t=-.97, p=.013). The nurse group in their 30s showed higher consent for end-of-life care than those in their 20s. An analysis of the correlation between the optimal end-of-life care and well-dying showed that there was no significant correlation. This study suggest that education should be provided to raise awareness of end-of-life care for young nurses with low experience.

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.

Energy Absorption of Collision Post Based on North American CFR Regulations for Railway Vehicles (철도차량의 북미 CFR 법규에 대한 충돌 기둥에너지 흡수에 관한 연구)

  • Kim, Seung-Tech;Jeong, Ji-Ho;Choi, Jeong-Yong;Woo, Kwan-Je
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.935-943
    • /
    • 2012
  • In accidents involving the collision of railway vehicles, there is a risk that structural members might penetrate the cab frame of the railway vehicle in the space in which the driver or passengers are seated. To reduce this risk, worldwide, studies on the collision of railway vehicles are underway. In North America, the Code of Federal Regulations (CFR) was revised in 2010 to include crush criteria for a collision and the corner post in an end frame. In this study, a crush analysis and crush test for a collision post and a crash analysis for a rigid cylinder were performed according to the CFR. The analysis and test results were compared and reviewed. This study aims to determine the usefulness of crush analysis for developing various end frames, and to understand the crush and crash characteristics and review the accuracy of the analysis.

End Bearing Behavior of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 선단지지거동)

  • Kwon, Oh Sung;Kim, Myoung Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.197-203
    • /
    • 2008
  • The end bearing behavior of piles socketed in weathered/soft rock is generally dependent upon the rock mass conditions with fractures rather than the strength of intact rock. Therefore, a database which includes 13 load tests performed on cast-in-place concrete piles and soil investigation data at the field test sites was made first, and new empirical relationships between the base reaction modulus of piles in rock and rock mass properties were developed. No correlation was found between the compressive strengths of intact rock and the base reaction modulus of weathered/soft rock. The ground investigation data regarding the rock mass conditions (e.g. Pressuremeter modulus and limit pressure, RMR, RQD) was found to be highly correlated with the base reaction modulus, showing the coefficients of correlation greater than 0.7 in most cases. In addition, the applicability of existing methods for the end bearing capacity of piles in rock was verified by comparison with the field test data.

The Relationships of End-of-life Care Stress with Compassionate Competence and Attitudes toward End-of-life Care among Pediatric Nurses

  • Park, Ki Young;Jeong, Jeong Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.24 no.4
    • /
    • pp.235-244
    • /
    • 2021
  • Purpose: This study aimed to provide basic data for developing interventions to relieve the end-of-life care stress experienced by pediatric nurses by examining the relationships of end-of-life care stress with compassionate competence and attitudes toward end-of-life care. Methods: Data were collected via a survey that was conducted from September 10 to September 30, 2018 and administered to 113 nurses who had worked for more than 6 months in a pediatric unit at a tertiary hospital in Seoul, South Korea. The data were analyzed for frequency, percentage, mean, and standard deviation, and the independent t-test, one-way analysis of variance, and Pearson correlation analysis were conducted using SPSS version 25.0. Results: End-of-life care stress among pediatric nurses had a weak positive correlation (r=0.216, P<0.05) with compassionate competence and had no significant correlation with attitudes toward end-of-life care. Among the sub-factors of end-of-life care stress, psychological difficulties had a weak positive correlation with sensitivity (r=0.309, P<0.01) and communication (r=0.230, P<0.05), which are aspects of compassionate competence. Lack of knowledge about end-of-life care had a weak positive correlation with communication (r=0.209, P<0.05) as an aspect of compassionate competence. Conclusion: To improve the quality of end-of-life care provided by pediatric nurses, it is necessary to improve their compassionate competence and reduce their end-of-life care stress by developing education and support programs tailored to the characteristics of children and specific communication methods.