• Title/Summary/Keyword: enclosure systems

Search Result 54, Processing Time 0.025 seconds

Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

Study on Nongray Gas Radiation within a Cylindrical Enclosure by Using the Narrow Band Model (좁은밴드모델을 이용한 실린더 내의 비회색 가스 복사열전달 연구)

  • Park, Won-Hee;Jung, Hyun-Sung;Kim, Tae-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.859-867
    • /
    • 2002
  • Radiative transfer in energy systems such as furnaces, combustors, boilers and high temperature machineries is a significant mode of heat transfer. Although there are many solution schemes suggested for analysis of radiative transfer in multi-dimensional systems, the applicabilities and accuracies of these schemes have not fully tested for nongray gases. Especially reference data for enclosures of non-orthogonal shapes are not yet enough. In this paper we present some precise radiative transfer solutions for a black walled 3-dimensional cylindrical system filled with nongray gases. The SNB(statistical narrow band) model and the ray-tracing method with the T$_{N}$ quadrature set are used for finding nongray solutions. Although the solution method used in this study is not suitable for engineering purposes, the resulting solutions are proved to be quite accurate and can be regarded as the exact solutions and the results presented in this paper can be used in developing various solution schemes fur radiative transfer by real gas mixtures.s.

Field Survey of Structural and Environmental Characteristics of Pig Houses in the Central Provinces in Korea (우리나라 중부지방 돈사의 구조 및 환경실태조사)

  • 최홍림;송준익;김현태
    • Journal of Animal Environmental Science
    • /
    • v.5 no.1
    • /
    • pp.1-15
    • /
    • 1999
  • The structural and environmental characteristics of typical pig houses in different growth phases were surveyed and analyzed. Based on the data for thirty six selected farms in four provinces, Gyonggi-do, Gangwon-do, Choongnam, and Chonbook, in Central Korea, the goal is to eventually establish standard pig houses of sow and litter, nursery pigs, and growing-finishing pigs. The survey included farm scale, production specialization, structural dimensions of the houses and their ventilation systems, cooling and heating systems, and floor and pit systems related to manure collection. The survey showed 90∼99% of growing-finishing curtain installation rate was lower by 10∼20%. The sidewall curtain system, although popular, is not well insulated which leads to excessive heating costs in winter. Regarding flooring and manure collection system of the house, there was quite a lot variability among provinces, with 30∼80% of the houses installing scraper systems with concrete-slat floors in comparison with 30∼60% using a slurry system. Gangwon-do and Choongbook Chungwoo-goon are the predominant regions that installed a scraper system. A general trend toward enlargement and enclosure of pig houses for all growth phases was gaining popularity in most regions in recent years. A steady shift to three site production from a lumped system was also observed to prevent a disease transfer. The structural design of a standard pig house with its environmental control systems including ventilation and heating/cooling system was suggested for further validation study. In-depth analysis of the survey data is presented in the Results and Discussing section.

Implementation of Active Noise Barriers Using Multiple Channel LMS Algorithms (다중채널 LMS 알고리즘을 이용한 능동방음벽 구현)

  • 남현도;서성대
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.147-153
    • /
    • 2003
  • In this paper, implementation of active noise barriers(ANB) to attenuate exterior noise which is propagated through open windows is presented. The leaky multiple channel LMS algorithms are used for adaptive filters tc improve the convergence property, and a new type of the active noise barrier is proposed. The attenuation effects of conventional active noise control(ANC) systems using leaky multiple channel LMS algorithms and the proposed system are compared by experiments using a TMS320C33 digital signal processor. Noise attenuation levels at the points of error microphones are similar for both systems, but average noise attenuation effects of the proposed system for an entire space of an experimental enclosure are much better than conventional ANC systems.

A Study on Perceived Problems of and Improvement Measures for Asbestos Abatement Companies in Support of Related Policies (석면 해체 및 제거 업체가 느끼는 관련 제도의 문제점 및 개선방안에 관한 연구)

  • Chang, Jaepil;Rho, Youngman;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.28-38
    • /
    • 2020
  • Objectives: The purpose of this study is to identify the perceived problems of and suggest improvement measures for asbestos abatement companies in support of asbestos-related systems and policies. Methods: For this study a questionnaire was prepared consisting of current work (two questions), the contribution and necessity of a risk assessment system for asbestos abatement (two questions), and problems with and improvement measures for systems and policies (nine questions). The questionnaires were sent to 2,170 asbestos abatement companies and were returned by 83 companies (return rate = 3.8%). We conducted frequency analysis, ANOVA, and a Chi-squared test at the 5% significance level. Results: Asbestos abatement companies expressed difficulties with complying with wet work (43% of unenrolled managers), negative pressure enclosure (36% of all respondents), and installation and use of decontamination units (26% of all respondents) as stipulated in the relevant regulations. In addition, 43% of the respondents expressed concerns that the expertise of the company was not considered during bidding for asbestos abatement and hoped that an advantage (e.g., bid point) would be given to the upper grades for asbestos risk assessment (38%). Asbestos abatement companies generally rented and used negative pressure devices (including negative pressure recording devices) and suggested that periodic calibration (32%) is needed to ensure the performance of the rented equipment. Finally, the respondents asked for clear definitions for three situations specified in the Occupational Safety and Health Acts: (1) temporarily leaving the asbestos abatement workplace; (2) tasks with less airborne asbestos; and (3) physically breaking or cutting using a machine. Conclusions: The problems and improvement measures identified in this study of asbestos abatement companies can be utilized as fundamental information for the improvement of the systems and policies for safe asbestos abatement.

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

Effectiveness and Ecological Implications of Anuran Defenses against Snake Predators

  • In-Ho Choi;Sung Ho Lee;Robert E. Ricklefs
    • Animal cells and systems
    • /
    • v.3 no.3
    • /
    • pp.247-252
    • /
    • 1999
  • The aim of this study was to characterize antipredator tactics of anurans and to evaluate the effectiveness of these tactics for predator avoidance in real confrontations. Two types of experiments were conducted. In one experiment, one predator and one prey were placed together for one hour in a small confined space (one-to-one interaction). In another experiment, one predator and several prey were placed together for one day in a large enclosure in a field (field-based interaction). The prey consisted of three anuran species, Rana nigromaculata, R. rugosa, and Bombina orientalls: a snake species, Rhabdophis tigrinus tigrinus, was used as a predator. Results of both experiments demonstrated a range in antipredator responses of the frogs, from toxicity and warning coloration, coupled with slow responses in Bombina to little (or only slight) toxicity, crypsis, and fast take-off responses to the predator in the ranids. oth ranid species exhibited lower survival(57%) than Bombina (95%) in the field-based interaction, suggesting that motor responses of the palatable prey due to attacks of the predator ultimately limited their survival. The jumping of the ranids increased the activity of the predator, which became more likely to strike. Simple crouching(seen in R. rugosa and B. orientalis) and chemical defense (in Bombina) reduced predatory attacks.

  • PDF

Different tolerance of zooplankton communities to insecticide application depending on the species composition

  • Sakamoto, Masaki;Tanaka, Yoshinari
    • Journal of Ecology and Environment
    • /
    • v.36 no.2
    • /
    • pp.141-150
    • /
    • 2013
  • Natural zooplankton communities are composed of many different species at different trophic levels in the aquatic food web. Several researchers have reported that in mesocosm/enclosure experiments, larger cladocerans tend to be more sensitive to carbamate insecticides than smaller ones (Daphnia > Moina, Diaphanosoma > Bosmina). In contrast, results from individual-level laboratory tests have suggested that large cladoceran species are more tolerant than small species. To clarify this inconsistency, we conducted a microcosm experiment using model zooplankton communities with different species compositions, where animals were exposed to lethal (near to the 24 h LC50, concentration estimated to kill 50% of individuals within 24-h for the small cladoceran Bosmina) and lower, sublethal concentrations of carbaryl. In the experiment, population densities of the small cladocerans (Bosmina and Bosminopsis) decreased subsequent to the applications of chemical, but no impacts were observed on the large cladoceran Daphnia. Our results supported the reports of previous individual level toxicity tests, and indicated that the sensitivity of zooplankton to the insecticide was unchanged by biological interactions but the response of population can be modified by compensation of population through hatching from resting eggs and/or the persistence of insecticide in the systems.

Optimal Position Selection of Microphones and Specters in Adoptive Noise Control System (능동소음제어 시스템의 마이크로폰 및 스피커 최적위치 선정)

  • 남현도;이홍원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.90-97
    • /
    • 2004
  • In this paper, the optimal position selection of error microphones and control speakers to attenuate interior noise from outside noise sources using active noise control techniques is presented. To get an optimal control characteristics of adaptive noise control systems, it is necessary to optimize the positions of microphones and speakers. New type of simulated annealing method has been proposed as searching techniques to find optimal speakers and microphones positions in which the sum of the squared pressures at microphone positions in an enclosure can be best minimized. Computer simulations and experiments have been performed to show the effectiveness of the proposed method.

Development of the Moisture Protected Computer - Efficiency Test of the MPC - (수분 밀폐형 컴퓨터시스템(MPC) 개발 - MPC의 성능평가 -)

  • Kim, Jin-Hyun;Kim, Tae-Wook;Sung, Kwang-Kee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • The MPC(Moisture Protected Computer) system is completely unique. It was recently invented in Korea and it is a technological break-through in the field of computer systems. It will be instrumental in the development of a complete moisture air-tight capability and will work well in field environments. The MPC includes the following: 1) An enclosed design. 2) Moisture proof computer enclosure joints. 3) System dust protection & an impact buffing system. 4) A normal temperature maintenance system when the temperature inside the computer is low. 5) The ability to generate heat and a radiate system inside the computer 6) An automatic power input sensing controller device. 7) A safety device in case of mis-operation. 8) A proper admission procedure for various tests. Because of the above, and as a result of temperature property experiments, there aren't any operational problems. The result of this treatise could provide very important data for verification of cases involving: using strong materials to protect against explosions, searching for ways to make the size and weight small, and for making repairs easier. As a result, it could achieve price and function competitiveness in advanced countries such as the USA and in Europe.

  • PDF