• 제목/요약/키워드: emission coefficient

검색결과 449건 처리시간 0.024초

공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구 (An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom)

  • 이태강;고광필;김항;송국곤;김선우
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Standardized Uptake Values Highly Correlate with Tumor Size and Fuhrman Grade in Patients with Clear Cell Renal Cell Carcinoma

  • Polat, Emre Can;Otunctemur, Alper;Ozbek, Emin;Besiroglu, Huseyin;Dursun, Murat;Ozer, Kutan;Horsanali, Mustafa Ozan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7821-7824
    • /
    • 2014
  • Background: We investigated the correlation between standardized uptake value (SUVmax), tumor size and Fuhrman grade in patients with renal cell carcinoma (RC). Materials and Methods: We retrospectively analyzed the data of 54 patients with clear cell renal cell carcinoma histopathologically diagnosed who underwent fluorine-18 fluoro-2 deoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) between January 2005 and March 2014. Results: Avarage tumor sizes were $5.64{\pm}1.85$, $6.85{\pm}2.24$ and $7.98{\pm}2.45$ in low, medium and high SUVmax groups, respectively. The Spearman's correlation coefficient between the tumor size and SUVmax was 0.385 (p=0.004) and between the Fuhrman grade and SUVmax was 0.578 (p<0.001). Conclusions: SUVmax appears highly correlated with tumor size and Fuhrman grade in patients with histopathologically confirmed clear cell RC. Multicenter studies are needed to provide larger series for more accurate results.

흑삼에서 벤조피렌의 추출 조건 및 분석 방법에 관한 연구 (Study on Extraction Condition and Analysis Methods of Benzopyrene in Black Ginseng)

  • 조영호;송규용;백명기;이종화;이계원
    • 약학회지
    • /
    • 제56권3호
    • /
    • pp.145-151
    • /
    • 2012
  • To develop fundamental data of herbal materials with heat treatment, we studied analytical and extraction methods of benzopyrene in black ginseng and validated by HPLC analysis. Benzopyrene was successfully separated in mobile phase of acetonitrile:water (80 : 20) and detection of excitation 294 nm, emission 404 nm. The calibration curve of benzopyrene was linear over the concentration range of 1.17~37.50 ng/ml with correlation coefficient of above 0.999. The limit of detection (LOD) and quantitation (LOQ) of benzopyrene was 0.25 and 0.75 ng/ml, respectively. Hexane extraction method was used as a new extraction method for benzopyren and the efficient of extraction was over 95%. In conclusion, analytical method and extraction method were suitable for the determination of benzopyrene in the black ginseng and could be applied to fundamental study and guideline of herbal materials with heat treatment.

Pt/Cr 이중층을 이용한 미세 발열체의 제작과 발열특성 (A thermal properties of micro hot-plate fabricated by using the Pt/Cr bilayer)

  • 이승환;서임춘;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1982-1984
    • /
    • 1996
  • In this paper, we have evaluated the physical characteristicsof the Pt/Cr bilayer, fabricated the micro hot plate by using the Pt/Cr bilayer and E-beam evaporated oxide as a passivation layer, and simulated the thermal distribution by using the commercial software FIDAP. From the researches the sheet resistance of Pt/Cr bilayer didn't be affected by the Cr layer thickness. This results was considered due to the Cr-oxide resided at the interface between Pt and Cr layer. After manufacturing the hot plate, we measured its temperature by type k thermo-couple and I.R. thermo-vision system. In those experiments, the emission coefficient( ${\varepsilon}$ ) of the E-beam evaporated oxide was 0.5 and the temperature of centural region was reached about $305\;^{\circ}C$ at 1.3 watts. The temperature simulation obtained by FIDAP commercial package stewed that the temperature of centural region was about $311\;^{\circ}C$ after 5 sec.

  • PDF

Advances on heat pump applications for electric vehicles

  • Bayram, Halil;Sevilgen, Gokhan;Kilic, Muhsin
    • Advances in Automotive Engineering
    • /
    • 제1권1호
    • /
    • pp.79-104
    • /
    • 2018
  • A detailed literature review is presented for the applications of the heat pump technologies on the electric vehicles Heating, Ventilation and Air Conditioning (HVAC) system. Due to legal regulations, automotive manufacturers have to produce more efficient and low carbon emission vehicles. Electric vehicles can be provided these requirements but the battery technologies and energy managements systems are still developing considering battery life and vehicle range. On the other hand, energy consumption for HVAC units has an important role on the energy management of these vehicles. Moreover, the energy requirement of HVAC processes for different environmental conditions are significantly affect the total energy consumption of these vehicles. For the heating process, the coolant of internal combustion (IC) engine can be utilized but in electric vehicles, we have not got any adequate waste heat source for this process. The heat pump technology is one of the alternative choices for the industry due to having high coefficient of performance (COP), but these systems have some disadvantages which can be improved with the other technologies. In this study, a literature review is performed considering alternative refrigerants, performance characteristics of different heat pump systems for electric vehicles and thermal management systems of electric vehicles.

Study of Al2O3/ZrO2 (5 nm/20nm) Nanolaminate Composite

  • Balakrishnan, G.;Wasy, A.;Ho, Ha Sun;Sudhakara, P.;Bae, S.I.;Song, J.I.
    • Composites Research
    • /
    • 제26권1호
    • /
    • pp.60-65
    • /
    • 2013
  • A nanolaminate consisting of alternate layers of aluminium oxide ($Al_2O_3$) (5 nm) and zirconium oxide ($ZrO_2$) (20 nm) was deposited at an optimized oxygen partial pressure of $3{\times}10^{-2}$ mbar by pulsed laser deposition. The nanolaminate film was analysed using high temperature X-ray diffraction (HTXRD) to study phase transition and thermal expansion behaviour. The surface morphology was investigated using field emission scanning electron microscopy (FE-SEM). High temperature X-ray diffraction indicated the crystallization temperature of tetragonal zirconia in the $Al_2O_3/ZrO_2$ multilayer-film was 873 K. The mean linear thermal expansion coefficient of tetragonal $ZrO_2$ was $4.7{\times}10^{-6}\;K^{-1}$ along a axis, while it was $13.68{\times}10^{-6}\;K{-1}$ along c axis in the temperature range 873-1373 K. The alumina was in amorphous nature. The FESEM studies showed the formation of uniform crystallites of zirconia with dense surface.

직접 광대전의 대전특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Direct Photoelectric Charging)

  • 이창선;김용진;김상수
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.753-759
    • /
    • 2000
  • Photoelectric charging is a very efficient way of charging small particles. This method can be applied to combustion measurement, electrostatic precipitator, metal separation and control of micro-contamination. To understand the photoelectric charging mechanism, particle charging of silver by exposure to ultraviolet is investigated in this study. Average charges and charge distributions are measured at various conditions, using two differential mobility analyzers, a condensation nucleus counter, and an aerosol electrometer. The silver particles are generated in a spark discharge aerosol generator. After that process, the generated particles are charged in the photoelectric charger using low-pressure mercury lamp that emits ultraviolet having wavelength 253.7 nm. The results show that ultra-fine particles are highly charged by the photoelectric charging. The average charges linearly increase with increasing particle size and the charge distribution change with particle size. These results are discussed by comparison with previous experiments and proposed equations. It is assumed that the coefficient of electron emission probability is affected by initial charge. The results also show that the charge distribution of a particle is dependent on initial charge. Single changed particle, uncharged particle and neutralized particle are compared. The differences of charge distribution in each case increase with increasing particle size.

교통환기력에 의한 터널내 환기량 추정에 관한 연구 (Estimation of Ventilation Volume by Traffic Ventilation Force in Tunnel)

  • 김종호;이상칠;도연지;김신도
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.273-278
    • /
    • 1995
  • This study is to estimate the ventilation volume by the traffic that originated from driving automobiles for two tunnels (Kugi tunnel and Kumhwa tunnel) that adopted natural ventilation system among tunnels of Seoul, and on the basis of which, we estimated the ventilation velume at various conditions. With the result of the estimation, we will present the basic method that can be operated with the optimum condition for the ventilation system. Estimating the predicted ventilation volume in the tennel by the pollutant concentration, we used traffic volume and CO emission data by the automobile speed and CO concentration in the tunnel. And, when we estimated the traffic ventilation volume by natural and traffic ventilation force, we used traffic volume, automobile speed, tunnel area, automobile area data and so on. As the result of simple regression between predicted ventilation volume and traffic ventilation volume, we attained the regression coefficient 0.88, and achieved the relation form that predicted ventilation volume equal 0.12x traffic ventilation volume-92, 000. Using this equation, we estimated the ventilation volume to satisfy the enviromnental standards of several space, and calculated the required volume for mechanical ventilation. Incase of Kumhwa Tunnel, there is a need of mechanical ventilation all day long to satisfy air quality standard 9 ppm for 8 hours average and 10 ppm for the indoor air quality standard of public facilities.

  • PDF

Structural and discharge characteristics of MgO films prepared by Arc Ion Plating (AIP) method

  • Kim, Jong-Kuk;Kim, Do-Geun;Lee, Eun-Sung;Lee, Sung-Hun;Lee, Gun-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.625-627
    • /
    • 2002
  • MgO thin films were deposited on glass and (100) Si substrates by an Arc Ion Plating (AIP) equipment using a magnesium metal target at various oxygen gas flow. In this work, we investigated the relationship between the structural properties and the discharge characteristics of MgO coating layers. X-ray diffraction and AFM have been used to study behaviors of the structure and surface morphology. The optical transmittance and the ion induced secondary electron emission coefficient of the MgO films have been also measured. The resistivity of the deposited MgO films was gradually increased from 0.17 G ohm/${\square}$ to 0.35 G ohm/${\square}$ with the oxygen gas flow. The growth rate of the MgO coating layer was decreased with increasing the oxygen gas flow, while the optical transmittance was improved.

  • PDF

스월유동이 분무특성에 미치는 영향에 관한 연구 (Study on the Effect of Swirl Flow on Spray Characteristics)

  • 최승환;전충환;장영준
    • 한국분무공학회지
    • /
    • 제7권1호
    • /
    • pp.14-20
    • /
    • 2002
  • It is well known that the flow and spray characteristics is critical factor on the performance and emission of a direct injection diesel engine. So this study aims to investigate the interaction of flow and spray characteristics. At first, in cylinder flow distributions in swirl adaptor for 4-valve cylinder head of DI Diesel engine were investigated under steady conditions for different SCV angles mounted on the cylinder head with steady rig test and 2-D LDV. And the in-cylinder flow was quantified in terms of mean flow coefficient and swirl ratio/tumble ratio. It was found that the swirl ratio is controlled between 2.3 and 3.8. Then spray characteristics of the intermittent injection were investigated. PDA system was utilized for measurement of a droplet size and velocity. The analyses of the PDA results are carried out with Time Dividing Method. It was found that there is a correlation between the swirl flow and SMD. The droplet size and the velocity were nearly constant value with each SCV angle. And the swirl ratio is higher, SMD smaller. The swirl ratio was helpful factor to the atomization of droplet.

  • PDF