• 제목/요약/키워드: elevated station

검색결과 63건 처리시간 0.033초

Physicochemical Properties of Indoor Particulate Matter Collected on Subway Platforms in Japan

  • Ma, Chang-Jin;Matuyama, Sigeo;Sera, Koichiro;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.73-82
    • /
    • 2012
  • This study was aimed to thoroughly estimate the characteristics of indoor particulate matter (PM) collected on subway platforms by the cooperative approach of semi-bulk and single particle analyses. The size-resolved PM and its number concentration were measured on the platform in a heavily traveled subway station in Fukuoka, Japan. Particle Induced X-ray Emission (PIXE) and micro-PIXE techniques were applied to the chemical analyses of semi-bulk and single particle, respectively. There was the close resemblance of timely fluctuation between PM number concentration and train service on the third basement floor (B3F) platform compared to the second basement floor (B2F) and its maximum level was marked in rush hour. Higher number counts in large particles ($>1{\mu}m$) and lower number counts in fine particles ($<1{\mu}m$) were shown on the platform compared to an above ground. PM2.5 accounted for 58.2% and 38.2 % of TSP on B3F and on B2F, respectively. The elements that were ranked at high concentration in size-resolved semi-bulk PM were Fe, Si, Ca, S, and Na. The major elements tending to have more elevated levels on B3F than B2F were Fe (4.4 times), Ca (17.3 times), and Si (46.4 times). Although concentrations were very low, Cr ($11.9ng\;m^{-3}$ on B3F, $2.4ng\;m^{-3}$ on B2F), Mn ($3.4ng\;m^{-3}$ on B3F, $0.9ng\;m^{-3}$ on B2F), and Pb ($0.6ng\;m^{-3}$ on B3F, $1.6ng\;m^{-3}$ on B2F) were detected from PM2.5. Individual PM was nearly all enriched in Fe with Si and Ca. Classifying and source profiling of the individual particles by elemental maps and particle morphology were tried and particles were presumably divided into four groups (i.e., train/rail friction, train-rail sparking, ballast/abrasive, and cement).

요소(尿素)(Urea)를 시용(施用)한 초지(草地)의 토양단면(土壤斷面)에서 무기태질소(無機態窒素) 함량(含量)의 계절적(季節的) 변화 (Seasonal Change in Inorganic Nitrogen Content in the Soil Profile of Urea-Fertilized Grassland)

  • 윤순강;유순호
    • 한국토양비료학회지
    • /
    • 제24권3호
    • /
    • pp.171-176
    • /
    • 1991
  • 요소(urea)를 시용한 초지의 토양단면에서 무기태질소의 계절적 함량변화를 조사하기 위하여 질소 시용수준(施用水準)을 0, 14, 28 kg/10a로 하고 목초를 재배하면서 봄(5.26), 여름(7.27), 가을(10.18)철에 토양시료를 토양깊이 100cm 까지 20cm 간격으로 채취하여 분석(分析), 검토(檢討)한 결과는 다음과 같다. 1. 봄 철에 질소 무시용구에서는 $NH_4-N$ 함량이 높았으나 14, 28 kg N/10a 처리에서는 $NO_3-N$ 함량이 증가(增加)되었고 $NH_4-N$, $NO_3-N$ 함량은 토양깊이가 깊을수록 모두 감소되는 경향을 보였다. 2. 여름 철 토양 중 $NO_3-N$ 함량(含量)은 0 N < 14 N <28 N 순으로 증가되었고 28 N 처리에서는 토양중 평균 $NO_3-N$ 함량이 42 ppm였다. 3. 가을 철에는 $NH_4-N$ 함량은 전 처리에서 여름 철과 큰 차이가 없었으나 $NO_3-N$ 함량은 여름 철에 비하여 크게 감소(減少)되어서 14 N, 28 N 처리에서 각각 7, 14 ppm 이하로 낮아졌다. 4. 토양 중 전질소 함량은 봄 철에 토양깊이 0~20cm에서 0 N에 비하여 28 N 처리에서 0.042% 낮았으며 전체적으로는 0 N과 28 N 처리 사이에 차이가 적었다. 그러나 토양 전질소(全窒素) 함량에 대한 무기태질소(無機態窒素) 함량 비율은 0 N과 28 N 처리 간에 차이가 컸는데 여름 철에 28 N 처리의 토양깊이 40~100cm에서 무기태질소(無機態窒素) 함량비율은 0 N 처리에 비하여 크게 증가(增加)되었으며 특히 토양깊이 80~100cm에서는 0 N에 비하여 2배 이상 증가되었다.

  • PDF

시설내 고온에 대한 소나무 유묘의 생장반응 (Growth Responses of Pinus densiflora Seedlings to High Temperature in Container Culture)

  • 김종진;홍성각;윤택승
    • 생물환경조절학회지
    • /
    • 제12권4호
    • /
    • pp.217-220
    • /
    • 2003
  • 본 연구는 여름철 시설양묘시 생장 장해 요인으로 작용하고 있는 시설내 고온에 대한 수목 유묘의 생장 반응을 탐구하고자 임업시설양묘를 통하여 현재 우리나라에서 가장 많은 양의 묘목이 생산되고 있는 소나무(Pinus drnsiflora S. et Z.)를 대상으로 PE house 내에 일일최고온도가 각각 30~35$^{\circ}C$, 35~40$^{\circ}C$ 및 40$^{\circ}C$ 이상 등 세 수준의 온도로 설계된 장소에서 실시되엇다. 생육 6주 후부터 상대적으로 온도가 높은 생육장소의 소나무 수고생장의 감소가 관측되었으며, 특히 40$^{\circ}C$ 이상의 생육장소에서 자란 묘목의 생장감소가 시험 전 기간을 토하여 뚜렷하게 나타났다. 근원 경생장의 경우에도 상대적인 고온에서 자란 묘목의 생장이 낮아 40$^{\circ}C$ 이상의 경우 30~35$^{\circ}C$에서 보다 17.3%의 생장감소가 관찰되었다. 건중량의 경우 생육 10주 후의 지상부와 지하부 건중량은 30~35$^{\circ}C$에서 자란 묘목에서 가장 높은 건중량을 나타내었으나 다른 두 처리 사이에서와 유의성은 나타나지 않은 반면 생육 16주 후의 건중량에서는 지상부, 지하부 모두 고온에 따른 차이가 나타났다. 한편 T/R율은 고온에서 자란 묘목일수록 높았다. 본 실험에서의 결과와 같이 여름철 고온에 의한 생장 감소는 건전 유량묘목 생산에 크게 영향을 끼치므로 PE 온실에서 양묘를 수행할 때애는 고온 조절에 보다 유의해야 할 것이다.

Antihepatotoxic effect of Heat-treated Allium victorialis var. platyphyllum in $CCl_4-induced$ Rats and the Gas Chromatographic Analysis of Volatile Sulfur Substances

  • Park, Hee-Juhn;Jung, Hyun-Ju;Lim, Sang-Cheol;Jung, Won-Tae;Kim, Won-Bae;Park, Kwang-Kyun;Lee, Jin-Ha;Choi, Jong-Won
    • Natural Product Sciences
    • /
    • 제11권2호
    • /
    • pp.67-74
    • /
    • 2005
  • The ethanolic extracts of the leaves and bulbs of Allium victorialis var. platyphyllum (Liliaceae) collected from Daegwallyoung (D) and Ullung Island (U) in Korea were obtained using three different extracting methods. The first extracts, DL-1 DB-1, UL-1 and UB-1, were obtained from leaves (L) and bulbs (B) dried at $90^{\circ}C$, respectively, and the second extracts, DL-2, DB-2, UL-2 and UB-2, were obtained by extracting the leaves and bulbs of fresh plant parts. The third extracts DL-3, DB-3, UL-3 and UB-3 were obtained by incubating leaves and bulbs at $36^{\circ}C$. The six extracts obtained from A. victorialis var. platyphyllum at Daegwanllyoung (cultivated site) were orally administered to examine for a possible antihepatotoxic effect in $CCl_4-induced$ rats. DL-1 exhibited the most pronounced effect. The extracts inhibited serum ALT, AST, SDH, ${\gamma}-GT$, ALP and LDH activities elevated by $CCl_4$ injection and attenuated decreased glutathione S-transferase, glutatione reductase and ${\gamma}-glutamylcysteine$ synthetase activities and a decreased hepatic glutathione. However, the extracts obtained from Ullung Is. (native site) were less active than the extracts from Daegwallyoung, suggesting that A. victorialis var. platyphyllum from the cultivated site is more useful for functional food than of native site. These results also suggest that the antihepatotoxic effect is due to a higher content of hepatic glutathione. Gas chromatography of the twelve extracts showed significantly different sulfides, disulfides or trisulfides contents belonging to volatile sulfur substances (VSS). Nine components were identified on the basis of their mass spectra, namely, dimethyl disulfide, dimethyl trisulfide, diallyl disulfide, dipropyl disulfide, allyl methyl sulfide, allyl methyl trisulfide, 2-vinyl-4H-1,3-dithiin, 3,4-dihydro-3-vinyl-1,2-dithiin, and allithiamine. Extract DL-1 had the highest VSS content. Dried plant materials contained larger amounts of the VSSs than other extracts, and the leaves contained larger amount than the bulbs. These results suggest that heat treatment increases the antiheaptotoxic ability of A. victorialis var. platyphyllum by increasing the proportion of VSSs.

Reconstructing Atmospheric CO2 Concentration Using Its Relationship with Carbon Isotope Variations in Annual Tree Ring of Red Pine

  • Choi, Woo-Jung;Lee, Kye-Han;Lee, Sang-Mo;Lee, Seung-Heon;Kim, Han-Yong
    • 한국환경농학회지
    • /
    • 제29권4호
    • /
    • pp.362-366
    • /
    • 2010
  • Carbon isotope ratio ($^{13}C/^{12}C$, expressed as ${\delta}^{13}C$) of tree ring can be proxy of atmospheric $CO_2$ concentration ([$CO_2$]) due to the inter-correlation between atmospheric [$CO_2$], ${\delta}^{13}C$ of atmospheric $CO_2$, and ${\delta}^{13}C$ of plant tissue that assimilates atmospheric $CO_2$. This study was conducted to investigate if ${\delta}^{13}C$ of tree ring of Pinus densiflora in polluted area may show a lower value than that in unpolluted area and to explore the possibility of reconstructing atmospheric [$CO_2$] using its relationship with ${\delta}^{13}C$ of tree ring. During the period between 1999 and 2005, ${\delta}^{13}C$ of tree annual ring tended to decrease over time, and the ${\delta}^{13}C$ in polluted area (-27.2‰ in 2009 to -28.3‰ in 2005) was significantly (P<0.001) lower than that (-26.0‰ in 1999 to -27.1‰ in 2005) in unpolluted area. This reflects a greater emission of $CO_2$ depleted in $^{13}C$ in the polluted area. Atmospheric [$CO_2$] was significantly (P<0.01) correlated with ${\delta}^{13}C$ of tree ring in a linear fashion. Using the linear regression equation, atmospheric [$CO_2$] in the polluted area was estimated to range from 392.3 ppm in 1999 to 410.9 ppm in 2005, and these values were consistently higher than the national atmospheric [$CO_2$] monitored at the Anmyoundo meteorological station (from 370.7 ppm in 1999 to 387.2 ppm in 2005). Our study suggested that it is possible to reconstruct atmospheric [$CO_2$] in a certain area using the relationship between tree ring ${\delta}^{13}C$ and atmospheric [$CO_2$].

관측과 모델 자료를 활용한 겨울철 영동지역 한기 축적(Yeongdong Cold Air Damming; YCAD)의 공간 규모 분석 (An Analysis on the Spatial Scale of Yeongdong Cold Air Damming (YCAD) in Winter Using Observation and Numerical Weather Model)

  • 남형구;정종혁;김현욱;심재관;김백조;김승범;김병곤
    • 대기
    • /
    • 제30권2호
    • /
    • pp.183-193
    • /
    • 2020
  • In this study, Yeongdong cold air damming (YCAD) cases that occur in winters have been selected using automatic weather station data of the Yeongdong region of Korea. The vertical and horizontal scales of YCAD were analyzed using rawinsonde and numerical weather model. YCAD occurred in two typical synoptic patterns such that low pressure and trough systems crossing and passing over Korea (low crossing type: LC and low passing type: LP). When the Siberian high does not expand enough to the Korean peninsula, low pressure and trough systems are likely to move over Korea. Eventually this could lead to surface temperature (3.1℃) higher during YCAD than the average in the winter season (1.6℃). The surface temperature during YCAD, however, was decrease by 1.3℃. The cold air layer was elevated around 120 m~450 m for LP-type. For LC-type, the cold layer were found at less than approximately 400 m and over 1,000 m, which could be thought of combined phenomena with synoptic and local weather forcing. The cross-sectional analysis results indicate the accumulation of cold air on the east mountain slope. Additionally, the north or northeasterly winds turned to the northwesterly wind near the coast in all cases. The horizontal wind turning point of LC-type was farther from the top of the mountain (52.2 km~71.5 km) than that of LP-type (20.0 km~43.0 km).

서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발 (Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map)

  • 이은선;박민빈;이태정;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Benzimidazole계 살균제의 세포독성 평가 (Risk assessment on cytotoxicity for benzimidazole fungicides)

  • 이제봉;성필남;정미혜;신진섭;강규영
    • 농약과학회지
    • /
    • 제7권3호
    • /
    • pp.198-206
    • /
    • 2003
  • Benzimidazole계 살균제의 세포독성을 평가하기 위하여 CHL(chinese hamster lung) 세포를 이용한 Giemsa stain assay, Lactic dehydrogenase(LDH) activity, MTT assay, DNA synthesis inhibition test 및 Sulforhodamin B(SRB) assay를 수행하여 benzimidazole 계 살균제에 대한 약제별 세포독성을 평가하고 위해도 평가를 위한 자료로 사용하고자 하였다. 시험결과 LDH 활성은 carbendazim 4.0, 16.0 및 $32.0{\mu}g/mL$을 24 시간 처리하였을 때 음성대조군에 비해 농도별로 세포독성이 각각 2.16, 2.94 및 2.64배 강하게 나타났다. DNA 합성시험에서는 carbendazim $2.0{\mu}g/mL$ 농도에서 약 45% DNA 합성을 저해하였으며, Giemsa assay와 MTT assay에서도 세포와 mitochondria에 독성을 일으키는 것으로 나타났다. Giemsa assay의 $IC_{50}$은 thiophanate-methyl, benomyl, carbendazim 및 양성대조 약제인 captafol에서 각각 >125, 1.2, 30.0 및 $0.3{\mu}g/mL$ 이었고, MTT assay의 $IC_{50}$은 thiophanate-methyl, benomyl, carbendazim 및 captafol에서 각각 >125, 18.7, 20.4 및 $2.6{\mu}g/mL$이었다. 그리고 세포 증식에 대한 영향을 조사하기 위하여 수행된 SRB assay 의 $IP_{50}$(반수세포증 식억제농도)에서도 thiophanate-methyl, carbendazim, benomyl 및 captafol이 각각 17.4, 5.3, 1.5, 및 $0.5{\mu}g/mL$으로 관찰되었다. 이상의 결과는 급성독성이 낮은 benzimidazole계 살균제가 유전독성 등 특수독성이 강하게 나타나는 원인일 것으로 판단되었다.

우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴 (A Definition of Korean Heat Waves and Their Spatio-temporal Patterns)

  • 최광용
    • 대한지리학회지
    • /
    • 제41권5호
    • /
    • pp.527-544
    • /
    • 2006
  • 본 연구는 우리나라 실정에 맞는 여름철 강한 무더위인 열파(Heat Wave)를 정의하고, 각 강도별 장기간(1973-2006) 평균적인 열파 발생빈도의 시공간적 분포 특징을 밝히고자 하였다. 고온다습한 한반도 여름몬순 기후하에서 체감온도와 사망자의 관계를 분석하여, 최소 $32.5^{\circ}C$$35.5^{\circ}C,\;38.5^{\circ}C,\;41.5^{\circ}C$의 일최고 열지수(Heat Index)가 3일간 지속되었을 때를 더운기간(Hot Spell) 및 열파(Heat Wave), 강한열파(Strong Heat Wave), 매우강한열파(Extreme Heat Wave) 발생일로 정의하였다. 이를 바탕으로 모든 단계별 열파 연평균 발생빈도를 살펴보면, 해발고도가 높은 고지대나 바다에 인접한 도서지역에서는 낮게 나타나는 반면, 주요 대하천에 인접한 내륙 저지대에서는 연평균 열파 발생빈도 뿐만 아니라 연구기간중 연 최다 열파 발생일수도 장마휴지기(7월 하순-8월 초순)를 중심으로 높게 나타난다 연구기간(1973-2006) 동안 각 단계별 열파일 발생빈도에는 뚜렷한 변화가 없었으나, 더운기간 (Hot Spell)의 최고 발생빈도를 기록한 연도는 1970년대에, 열파(Heat Waves)와 강한열파(Strong Heat Wave)의 최고 발생빈도를 기록한 연도는 1990년대에 각 집중되어 나타났다. 한편, 우리나라의 열파 발생시에는 기온 이외에도 습도의 부가적인 영향이 $4.3-9.5^{\circ}C$ 정도 열파(Heat Wave)의 강도를 높이고 있음을 알 수 있다. 이러한 연구 결과들은 우리나라에 맞는 국가 열파 경보 체계를 구축하는데 기초자료로써 활용될 수 있을 것으로 생각된다.커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다. 성장 억제 작용은 G0/Gl기를 지체시켜 암세포 증식을 억제하고 apoptosis에 의해 암세포를 사멸시키는 항암 활성을 나타내는 것으로 확인되었으며, 특허 AO가 AG보다 현저한 활성을 보였다. 더 나아가 아가리쿠스 $\beta$-glucan (AG)과 올리고당류 (AO)는 항암 활성을 가진 대체 의약 소재로 개발될 수 있을 것으로 기대된다.eruginosa rhlI의 경우 단일배양보다 혼합배양시 최고 약 40배, P. aeruginosa lasI의 경우 최고 약 250배 그리고 S. aureus luxS의 경우는 단일배양보다 혼합배양시 최고 약 5배 이상 mRNA 발현량이 증가하였다. 또한 세 균주의 4가지 유전자 중 P. aeruginosa의 rhlI와 lasI의 mRNA가 가장 많은 양으로 발현됨을 확인하였다.석되었다. 6. 연 강수량이 17.4% 증가해 월별 평균 강수량 변화가 가장 큰 시나리오 Al은 연 유출량이 24.6% 증가하고, 유사량과 TN, IP 부하량은 각각 60.1%, 14.4%, 27.1%증가하는 것으로 나타났으며, 이에 비하여 연 강수량 증가가 2.5%로 가장 작은 시나리오 B1의 연 유출량 변화는 -0.4% 감소하는 것으로 나타났고, 유사량과 TN, TP 부하량은 각각 14.6%, 3.0%, 7.2% 증가하는 것으로 모의되었다. 7. 강우 발생 일수 변화를 가정한 시나리오에 대한 모의 결과, 연강우일수가 약 10일 감소한 A1-1, A2-1, B1-1, B2-1의 경우, 강우 일수 감소 이전과 연 유출량 변화는 거의

고온 스트레스에 대한 배추의 생장과 광합성 및 엽록소형광 반응 (Growth, Photosynthesis and Chlorophyll Fluorescence of Chinese Cabbage in Response to High Temperature)

  • 오순자;문경환;손인창;송은영;문영일;고석찬
    • 원예과학기술지
    • /
    • 제32권3호
    • /
    • pp.318-329
    • /
    • 2014
  • 본 연구는 온도구배터널에서 자라는 배추의 잎에서 광합성적 $CO_2$ 교환과 엽록소형광을 분석함으로써 배추의 생장에 미치는 고온의 영향을 정량적으로 분석하였다. 결구가 형성되기 전의 생육초기에는 대기온도보다 대기온도 $+4^{\circ}C$와 대기온도 $+7^{\circ}C$ 조건에서 생장한 배추가 엽수의 증가와 엽길이의 신장이 두드러지게 나타났다. $CO_2$ 고정률은 대기온도 $+4^{\circ}C$에서 자란 배추의 잎에서 $25.8{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$로 다소 높았으나, 생육 온도에 따라 통계적으로 유의한 차이는 없었다. 반면에 호흡률은 대기온도에서 다소 높았으며 대기온도 $+4^{\circ}C$와 대기온도 $+7^{\circ}C$ 조건에서는 낮았다. 기공전도도와 증산률은 대기온도에서보다 대기온도 $+4^{\circ}C$와 대기온도 $+7^{\circ}C$ 조건에서 증가하고 수분이용효율은 감소하였다. 그리고, OKJIP 곡선의 패턴에서도 상승온도에서 $F_J$, $F_I$, $F_P$가 크게 낮아지고, 고온에서 특이적으로 나타나는 $F_K$의 증가와 $F_V/F_O$값의 감소 등을 확인할 수 있었다. RC/CS는 대조구에 비해 온도가 높아지면 크게 감소하였으며, ABS/CS, TRo/CS와 ETo/CS도 온도가 높아짐에 따라 점차 줄어들었다. 이에 반해 DIo/CS는 온도가 높아짐에 따라 증가하였다. 그리고 대조구인 대기온도에서는 정식 후 7주, 9주, 10주째에 수확한 배추 내부에서 병징이 나타나지 않았으나, 대기온도 $+4^{\circ}C$와 대기온도 $+7^{\circ}C$ 조건에서는 재배기간이 길어질수록 점차 무름병에 의한 피해가 두드러지게 나타났다. 이러한 결과는 급격하게 변화하는 미래의 기후 환경 하에서 배추가 고온 스트레스에 노출될 가능성을 암시하고 있다. 따라서 배추의 안정적인 생산을 위해서는 고온 적응성 품종, 특히 결구 시점에서 내고온성이 강한 품종을 육성하거나 고온의 피해를 최소화할 수 있는 재배기술이 확립되어야 할 것으로 보인다. 그리고 결구형성 시 고온 스트레스의 영향을 조기감별하기 위해서 OKJIP 곡선에서 $F_K$의 증가를 비롯하여 기존에 사용되고 있는 변수인 $F_O$, $F_V/F_M$$F_V/F_O$ 이외에도 $M_O$, $S_M$, RC/CS, ETo/CS, $PI_{abs}$, $SFI_{abs}$ 등의 형광변수들이 유용하게 활용될 수 있을 것으로 보인다.