• Title/Summary/Keyword: elevated station

Search Result 63, Processing Time 0.027 seconds

Vibration Analysis of an Elevated Railroad Station Considering Station-Bridge Connection Characteristics (교량 접속부 특성을 고려한 선하역사의 진동 해석)

  • Choi, Sanghyun;Kwon, Soonjung
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.274-281
    • /
    • 2014
  • Since the vibration induced by a train is transferred directly to a station via a roadbed structure, the elevated station is particularly vulnerable to noise and vibration. To establish more appropriate measures to reduce vibration, the structural behavior and damping characteristics depending on the structural type and the composition of a elevated station should be identified, because the noise inside the station is mainly structure borne noise by the vibration of a station structure. In this paper, the vibration characteristic changes depending on mechanical connection types between an elevated station and a connected bridge are analyzed. The finite element model for Daecheon Station is constructed for the purpose of this study, and the analysis is performed using ABAQUS. The analyses are conducted for with and without bridge connections, and for the bridge connections, ramen and bearing types are considered in the analysis.

Analysis of Vibration Transfer Characteristics of Approach Bridges for an Elevated Railroad Station (철도선하역사 접속교량의 진동전달 특성 분석)

  • Choi, Sanghyun;Kim, Jin-Ho;Yoo, Yong;Kwon, Se-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2911-2916
    • /
    • 2015
  • The elevated railway station, above which a train is passing, is vulnerable to noise and vibration compared to other station types. To better identify the vibration characteristics of the elevated railway station, the transferred vibration from approach bridges should be analyzed. In this paper, through experiments and simulations, the transfer characteristics of the vibration from approach bridges is analyzed. The study structure is Geomgok station and the anaylses are conducted using ABAQUS three dimensional numerical model. To identify the change in the transfer characteristics for various bearing types, the analyses are performed considering mechanical properties of bearing for railway bridges. The measurement is performed using the accelerometers attached to the approach bridges and the station structure along the passing path of trains.

The plan of minimization to the station of monorail (경전철(모노레일) 정거장 규모 최소화 방안에 관한 연구)

  • Ahn, Yong-Mo;Jeon, So-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.45-49
    • /
    • 2008
  • The monorail system as new transportation system mostly has being constructed as an elevated construction. In particular, in case of construction to elevated structure in the center of a city, it is important to decision for a monorail station to be considered the minimization. We must purchase the required lands prior to design the monorail stations because of separation of a platform and a waiting room. So We can exclude the problem that it have too close between a monorail station and the other building. Therefore the standard width and elevation of the monorail station shall be considered the efficient execution, economic and transportation. We have many thing to resolve as the plan of minimization to the station of monorail. But we know the ultimate in environmentally friendly transportation, of course, is our monorail system and we are positive as to a popular transportation craze.

  • PDF

Influence of Elevated CO2 and Air Temperature on Photosynthesis, Shoot Growth, and Fruit Quality of 'Fuji'/M.9 Apple Tree (CO2 및 기온 상승이 '후지'/M.9 사과나무의 광합성, 신초생장 및 과실품질에 미치는 영향)

  • Kweon, Hun-Joong;Sagong, Dong-Hoon;Park, Moo-Yong;Song, Yang-Yik;Chung, Kyeong-Ho;Nam, Jong-Chul;Han, Jeom-Hwa;Do, Gyung-Ran
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.4
    • /
    • pp.245-263
    • /
    • 2013
  • This study was conducted to find out the influence of elevated atmospheric $CO_2$ concentrations and air temperature on photosynthesis and fruit quality of 'Fuji'/M.9 apple trees and to investigate these to the effects of climate change during the last four years (2009-2012). The treatments employed were: 'Ambient' (ambient temperature + ambient $CO_2$ concentration); 'High $CO_2$' (ambient temperature + elevated $CO_2$ concentration); 'High Temp'. (elevated temperature + ambient $CO_2$ concentration); and 'High $CO_2$ + High Temp'. (elevated temperature + elevated $CO_2$ concentration). The elevated temperature plots were maintained at $4^{\circ}C$ higher than ambient air temperature, while the elevated $CO_2$ plots were maintained at 700 ${\mu}mol{\cdot}mol^{-1}$. Annual treatment period was applied from end of April to beginning of November for four years. Results showed that elevated $CO_2$ decreased stomatal conductance and leaf SPAD value, but increased photosynthetic rate, intercellular $CO_2$ concentration (Ci), and starch content of mesophyll tissue. In the vegetative growth, elevated temperature increased total number of shoot and total shoot growth per tree, but elevated $CO_2$ decreased average shoot length. In the fruit quality, elevated $CO_2$ increased soluble solid content, fruit red color, and ethylene production. In conclusion, elevated $CO_2$ increased photosynthetic rate of apples during the early growth, but effect of increased photosynthetic rate due to elevated $CO_2$ was decreased during latter growth stage. Elevated temperature, on the other hand, tended to decrease photosynthetic rate of apples during the early growth, but that tended to increase during latter growth stage. Both elevated $CO_2$ and temperature tended to decrease the degree of decreased photosynthetic rate due to each factor.

Experimental Analysis of Vibration Transfer Characteristics of an Elevated Railroad Station (철도 선하역사 진동 전달 특성의 실험적 분석)

  • Choi, Sanghyun;Yoo, Yong;Kim, Jinho;Kwon, Segon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2015
  • To reduce noise inside an elevated railroad station, the vibration of the station structure should be lowered, and to establish more effective anti-vibration measures it is required that, reflecting the track-bridge-structure interaction, the transfer characteristics of vibration induced by a train is well identified. In this paper, the current status of domestic railroad stations is classified, and the vibration transfer characteristics is analyzed via measurement data from representative elevated stations. From the analysis results on the measurement data, in transferring vibration from the track to the structure, remarkable vibration reduction in higher frequency range is observed, and, in some stations, amplified response characteristics in lower frequency range is identified. Also, for stations with floating track system or TPS type, relatively greater reduction in transferred vibration is observed.

The Reduction of Structure-borne Noise in an Elevated Station(Changdong Station) of Seoul Metro Line No. $1\sim4$ (서울메트로 $1\sim4$호선 고가역(창동역) 고체소음 저감 사례)

  • Kong, Sun-Yong;Oh, Hee-Wan;Kim, Sang-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.438-443
    • /
    • 2007
  • In the recent railway construction, the concrete slab track is highlighted as the maintenance-free track and the main stream is moving from ballasted track to concrete slab track. However, in spite of many merits of concrete slab track, the higher noise generated from the concrete slab track is a troublesome question to solve and, by this reason, many studies on noise reduction of concrete slab track are carried out. The railway noise can be classified into the reflection noise emitted from wheel/rail contact and the structure-borne noise transmitted through railway structures. In this presentation, we would like to introduce an example of the successful reduction of structure-borne noise at track retrofitting to maintenance-free concrete slab track in elevated Changdong Station which was built with ballasted track on Rahmen structure.

  • PDF

Air Pollutant Dispersion Phenomena at a Street under a Sky Train Station in Bangkok, Thailand

  • Hiyama, Kyosuke;Hoshiko, Tomomi;Prueksasit, Tassanee;Kato, Shinsuke;Koganei, Makoto
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • The ventilation performance of a street in Bangkok, Thailand, was investigated by performing measurements and conducting a CFD analysis. We focused on a street that was covered by an elevated train station. It was shown that the ventilation efficiency varied drastically depending on the angle between the street and the wind direction. When the wind direction was parallel to the street, the elevated structure had a negative influence, which created higher pollutant concentrations than in locations without elevated structures. However, when the wind direction was perpendicular to the street, the pollutant concentrations in the two situations were similar. Using a CFD analysis and ventilation performance indexes, it was shown that the elevated structure directed the wind flow and enhanced the ventilation efficiency, which positively affected ventilation performance. These kinds of knowledge can lead us to optimize city planning including high-rise buildings with high ventilation efficiency.

Thermal-pressure loading effect on containment structure

  • Kwak, Hyo-Gyoung;Kwon, Yangsu
    • Structural Engineering and Mechanics
    • /
    • v.50 no.5
    • /
    • pp.617-633
    • /
    • 2014
  • Because the elevated temperature degrades the mechanical properties of materials used in containments, the global behavior of containments subjected to the internal pressure under high temperature is remarkably different from that subjected to the internal pressure only. This paper concentrates on the nonlinear finite element analyses of the nuclear power plant containment structures, and the importance for the consideration of the elevated temperature effect has been emphasized because severe accident usually accompanies internal high pressure together with a high temperature increase. In addition to the consideration of nonlinear effects in the containment structure such as the tension stiffening and bond-slip effects, the change in material properties under elevated temperature is also taken into account. This paper, accordingly, focuses on the three-dimensional nonlinear analyses with thermal effects. Upon the comparison of experiment data with numerical results for the SNL 1/4 PCCV tested by internal pressure only, three-dimensional analyses for the same structure have been performed by considering internal pressure and temperature loadings designed for two kinds of severe accidents of Saturated Station Condition (SSC) and Station Black-out Scenario (SBO). Through the difference in the structural behavior of containment structures according to the addition of temperature loading, the importance of elevated temperature effect on the ultimate resisting capacity of PCCV has been emphasized.

A Study of Noise Characteristics Induced by Slab Vibration for the Elevated Railway Station (선하역사의 슬래브 진동에 의한 소음방사 특성에 관한 연구)

  • Kim, Jin-Ho;Jang, Dongdoo;Ji, Yong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3557-3566
    • /
    • 2015
  • In the case of elevated railway station in which railway is connected with superstructure of station, vibration and noise level is relatively higher than those of general structure type station due to structural characteristic which transmits vibration directly. Therefore, characteristic understanding of structural vibration and accompanying structure cause noise and establishment of reduction plan through the results are in need. Test and analysis are performed in this research to consider correlativity between structural vibration and accompanying structure cause noise when external forces are applied on standard slab and floating slab which is able to isolate vibration. By producing and loading on standard and floating slab, vibration and noise response are measured while simulation using numerical analysis, finite element method and SEA method is performed. The results about structural dynamic behavior of slab, correlativity between structural vibration and noise, reduction performance of floating slab is deduced through the analysis of tests.

Studies on the Cold Resistant in Rape, Brassica napus L. (유채 내한성에 관한 연구)

  • Kim, I.H.;Kwon, B.S.;Lee, J.I.;Yu, I.S.;Kim, J.K.;Lee, Y.B.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.26-34
    • /
    • 1977
  • 27 lines were selected for the cold resistant lines from the promising lines. The cold resistant lines were chiefly selected from Oro$\times$Norin 16, Oro$\times$Norin 20 and (Yudal$\times$Kongo)$\times$Yudal combination. The varieties of lately maturing showed cold resistantce. Transplanting treatment increased cold resistantce, and early sowing and drill planting also elevated cold resistance in the direct sowing culture. Plants to be cultured on soils with optimum moisture coutent showed higher cold resistance.

  • PDF