• Title/Summary/Keyword: electrorheological

Search Result 127, Processing Time 0.024 seconds

A Study on Bingham Characteristics of Particle Dispersive Electro-Rheological Fluid (입자분산계 ER유체의 빙햄특성 고찰)

  • 장성철;이선의;김태형;박종근;염만오
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.178-183
    • /
    • 2000
  • Electrorheological(ER) effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of zeolite and starch based ER fluid were reported. The ER fluids were constructed by mixing zeolite and starch power with two different dielectric oils. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply. The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to $200s^{-1}$ in 2 minutes.

  • PDF

An Electrorheological (ER) Study on the Silica Suspensions (실리카 현탁액의 전기유변학적 연구)

  • 주상현
    • The Korean Journal of Rheology
    • /
    • v.6 no.1
    • /
    • pp.49-59
    • /
    • 1994
  • 높은 전기장 하에서 다분산, 비구형 실리카/실리콘 오일 현탁액의 전기유변 (electrorheological, ER)현상을 살펴 보았다. 전기유변유체는 전기장 방향으로 사슬구조를 형 성하는 특성을 보이며 이것이 유변물성의 향상에 기여하는 것으로 알려졌다. 동적(dynamic) 상태 실험에서 전기장 하의 실리카 현탁액은 매우낮은 임계변형율(${\gamma}$c =0.1%)이상에서 비선 형 점탄성을 보였다. 저장탄성계수(G')는 변형율 변화에 손실탄성계수(G")는 매질의 점도 에 더 민감한 의존성을 보였다. 또한 겉보기 항복응력은 입자의 부피분율과 전기장에$\Phi$1.9E1.4 의 의존성을 보였는데 부피분율에 대한 의존성이 큰 이유는 0.1 이상의 부피분율에서 복합 사슬 구조 내의 입자들 간의 상호 정전효과가 지배적으로 나타나기 때문이라고 생각된다. 정상상태 실험에서는 부피분율이 크거나 높은 전기장 하에서 전단속도가 0.1sec-1 정도 이하 로 감소함에 따라 전단응력이 급겨히 증가하는 현상을 보였다. 그러므로 본질적인 동적 항 복응력을 얻기 위해서는 매우 낮은 전단속도 영역의 특이한 응력거동을 고려해야한다. 큰 전단속도 하에서는 hydrodynamic interaction의 영향으로 전단속도의 증가에 따라 전단응력 이 증가하였다. 이같은 전단응력의 거동을 계단전단실험으로 확인하였다.

  • PDF

Electrorheological Properties of Aminated Polyacrylonitrile Susupension (아민화 폴리아크로니트릴 유도체 현탁액의 전기유변학적 특성)

  • Choi, Ung-Su;Kim, Choong-Hyun
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.176-181
    • /
    • 2009
  • Aminated polyacrylonitrile as the new organic disperse phases of the anhydrous ER fluid has been synthesized and ER effect of the suspension composed of aminated polyacrylonitrile in silicone oil investigated. The suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 1.6 power on theelectric field. The current density and the conductivity of the of aminated polyacrylonitrile suspension increase with the electric field intensity and moreover the conductivity of the suspension is about 8 order of magnitude higher than that of the silicone oil. On the basis of the the results, aminated polyacrylonitrile suspension showed the ER flow behavior upon application of the electric field due to the polarizability of the branched amine polar group of the aminated polyacrylonitrile particles.

Mechanical Durability of ER Fluids and Performance Investigation of ER Dampers (ER유체의 기계적 내구성 및 ER댐퍼의 성능고찰)

  • 박우철;최승복;정재천;서문석;강윤수;여문수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1044-1047
    • /
    • 1996
  • This paper presents durability characteristics of electrorheological(ER) fluids which undergo a reversible phase change depending upon the imposition of electric fields. The field-dependent Bingham properties are subjected to be altered from long time use of the ER fluid. The level of the changed properties depends upon employed device and test conditions. A piston-rod system which has same mechanism as ER dampers is adopted in this study and tested by increasing operation cycle up to 1 million. Bingham properties of initial and us ER fluids are tested and compared. In addition, these ER fluids are applied to ER damper in order to evaluate damping force performance.

  • PDF

The Effect of phosphoric Ester of Cellulose on the Electrorheological Properties of Anhydrous ER Fluids (셀룰로오스의 인산 에스테르 반응이 비수계 ER 유체의 전기유변학적 특성에 미치는 영향)

  • 최웅수
    • The Korean Journal of Rheology
    • /
    • v.10 no.3
    • /
    • pp.143-151
    • /
    • 1998
  • 실리콘 오일에 인산처리 셀룰로오스 분말을 분산시킨 비수계 전기유변성(ER) 유체 의 전기유변 거동을 상온에서 최대 2.5KV/mm의 전기장하에서 실험하였다. 넓은 온도 영역 에서 사용이 가증한 비수계 ER 유체를 개발하기 위해 셀룰로오스의 인산 에스테르 반응이 ER 유체의 전기유변효과에 미치는 영향을 조사하였다. 먼저 여러 가지의 인산처리 농도로 처리된 인산처리 셀룰로오스 미립자를 분산시킨 ER 유체를 제조한 후 ER 유체의 유전상수, 전류밀도 및 전기전도도 등과 같은 전기적 특성을 측정하였으며 ER 유체의 전기유변 특성 또한 측정하였다. 인산처리 셀룰로오스가 분산된 비수계 ER 유체의 전류밀도는 셀룰로오스 의 인산 에스테르 반응에서의 인산처리 농도에 의해 조절할수 있음을 알수있었으며 셀룰로 오스의 인산처리 농도가 2.5 M과 3.0 M 사이일 때 인산처리 셀룰로오스가 첨가된 비수계 ER 유체의 전기유변효과 ($\tau$/$\tau$0)가 가장 높게 측정되었다.

  • PDF

Vibration Control of Quarter Vehicle ER Suspension System Using Fuzzy Moving Sliding Mode Controller (퍼지이동 슬라이딩모드 제어기를 이용한 1/4차량의 ER현가장치 진동제어)

  • Sung, Kum-Gil;Cho, Jae-Wan;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.644-649
    • /
    • 2006
  • This paper presents a robust and superior control performance of a quarter-vehicle electrorheological (ER) suspension system. In order to achieve this goal, a moving sliding mode control algorithm is adopted, and its moving strategy is tuned by fuzzy logic. As a first step, ER damper is designed and manufactured for a passenger vehicle suspension system, and its field-dependent damping force is experimentally evaluated. After formulating the governing equation of motion for the quarter-vehicle ER suspension system, a stable sliding surface and moving algorithm based on fuzzy logic are formulated. The fuzzy moving sliding mode controller is then constructed and experimentally implemented. Control performances of the ER suspension system are evaluated in both time and frequency domains.

  • PDF

The Electrorheological and Dielectric Behaviors of Conducting Polymer-coated Poly(ethyl methacrylate) Suspensions

  • Kim, Young-Dae;Park, Dong-Hyup;Nam, Suk-Woo;Park, Tae-Jin
    • Macromolecular Research
    • /
    • v.10 no.4
    • /
    • pp.215-220
    • /
    • 2002
  • The electrorheological (ER) and dielectric behaviors of the polypyrrole(PPy)-coated poly(ethyl methacrylate)(PEMA) suspensions in mineral oil were investigated. PPy was coated on PEMA particles to enhance the particle polarization, which would lead to the enhanced ER response. Various PPy-coated PEMA particles were synthesized by controlling the oxidant amount during the pyrrole polymerization, and the ER responses of their suspensions were investigated. The ER response initially increases with the oxidant amount, passes through a maximum, and then decreases with the oxidant amount. The initial increase in the ER response with oxidant amounts is due to the enhanced particle polarization with the increased particle surface conductivity. The dielectric properties of the corresponding suspensions support that the ER enhancement arises from the enhanced particle polarization. The decrease in the ER response at large oxidant amounts seems to arise from the increased conduction between the PPy-coated PEMA particles.

The Flow Visualization of ER Fluid Between Two Parallel-Plate Electrodes Separated by Small Distance (좁은 평행평판전극 사이의 ER유체 유동의 가시화)

  • Park, Myeong-Kwan;Rhee, Eun-Jun;Oshima, Shuzo;Yamane, Ryuichiro
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.801-810
    • /
    • 1999
  • The purpose of present research was to get characteristics and basic knowledges of electrorheological(ER) suspension. To observe behaviors of the ER suspensions. transparent conductive plates were used to visualize the flow of ER suspensions between two parallel plate electrodes. The influence of flowing speed and intensity of electric field on the ER fluid were examined in circle-shaped electric field, and it takes several hundred milliseconds that suspensions in flow cluster. The present study also conducts a numerical analysis adopting the Bingham model. It is found that simple Bingham model can not property describe the flow behavior in the parallel plates.

Bingham Charateristics of Electrorheological Fluid and Its Application to ER valve and ER Damper (전기유변유체의 빙햄특성과 밸브 및 댐퍼에의 응용)

  • 배종인
    • The Korean Journal of Rheology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • 전기장이 인가되고 있는 유로를 유동하는 전기유변유체의 기본성질을 파악하기 위 한 실험 및 해석적 연구를 수행하여 빙햄유체로서의 유효성에 대해 알아보고 전기장과 유로 면 형상 및 진동유동으로 인한 영향에 대해 조사함으로써 ER밸브 및 ER대퍼로의 응용과 관련한 감쇄력 제어에 대해 검토하였다. 첫 번째 실험은 ER밸브의 높이가 2mm인 적극면이 평탄한것과 요철로 된 것을 사용하여 압력손실을 압력변환기로 측정함으로써 전기장 및 유 로형상에 대한 영향을 알아보았다. 압력손실 및 전단응력이 전기자세기와 함수관계를 가짐 을 알수 있었고 전기장세기와 유속의 변화시 손실계수에 의한 ER효과의 상이함이 확인되었 으며 레이놀즈수가 커지면 항복전단응력의 영향은 나타나지 않았다. 두 번째 실험은 실린더 를 정현파로 진동시켜 ER밸브에서 감쇠력제어가 가능한가를 알아보고 빙햄유체모델로 설계 된 ER댐퍼의 모델과 비교하였다. ER배르와 ER댐퍼의 수학적 모델을 시뮬레이션한 결과는 약간 벗어남이 보이기는 하나 실험결과와 일치하요 있다. 이것은 ER유체를 단순히 빙행유 체로 취급할수없으나 거시적으로는 빙햄유체로 취급할수 있음을 시사한다.

  • PDF

Theoretical Approximate Solutions for Electrorheological Short Squeeze Film Dampers (무한 소폭 전기유변 스퀴즈 필름 댐퍼에 관한 이론적 근사해)

  • 정시영;최상규;강덕형
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.60-67
    • /
    • 1997
  • ER(electro-rheological) fluids, which are represented as Bingham fluids, have large and reversible changes in yield shear stresses by application of an electric field. In this paper, ER fluids are employed in a short squeeze film damper. The modified Reynolds equation for an ER short squeeze film damper is theoretically solved to get the approximate solutions of pressure profiles and damping coefficients. The theoretical approximate solutions are compared with numerical ones and both results are coincided very well. Both the direct and cross coupled damping coefficients substantially increase with increasing the yield shear stress of ER fluids. Furthermore, the synchronous response analysis of a rigid rotor supported on ER short squeeze film dampers is performed to show the improved damping capability of an ER short squeeze film damper.