• Title/Summary/Keyword: electronic skin

Search Result 250, Processing Time 0.024 seconds

Development of Wireless Electronic Cardiogram and Stethoscope (ECGS) to Measure ECG Signal and Heart Sound (심전도와 심음을 측정하기 위한 무선 전자 심전도-심음 청진기 개발)

  • Cho, Han Seok;Kang, Young-Hwan;Park, Jae-Soon;Choi, Jin Gyu;Joung, Yeun-Ho;Koo, Chiwan
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.124-130
    • /
    • 2022
  • In this paper, we proposed a portable electronic cardiogram and stethoscope (ECGS) that can simultaneously perform the electrocardiogram (ECG) and auscultation tests to increase the reliability of diagnosis of heart disease. To measure the ECG and heart sound (HS) at the same time, three ECG electrodes and a microphone sensor were combined into a triangular shape with a width of 90 mm and a height of 97 mm that can be held in one hand. In order to prevent skin problems when they contact the patient's skin, a capacitive coupled electrode was selected as the ECG electrode and a silicone material was used in a chest piece with the microphone sensor. For the signals measured from the electrodes and the chest piece, filters were respectively configured to pass only the signals of 0.01-100 Hz and 20-250 Hz, which are frequency bands for ECG and HS. The filtered ECG and HS analog signals were converted into digital signals and transmitted to a PC using wireless communication for monitoring them. The HS could be auscultated simultaneously using an earphone. The monitored ECG had an SNR of about 34 dB and a P-QRS-T waveform is clearly visible. In addition, the HS had an SNR of about 28 dB and both S1 and S2 are clearly visible. It is expected that it can aid doctors' inexperience in analyzing the ECG and HS.

Real Time Face Detection with TS Algorithm in Mobile Display (모바일 디스플레이에서 TS 알고리즘을 이용한 실시간 얼굴영역 검출)

  • Lee, Yong-Hwan;Kim, Young-Seop;Rhee, Sang-Bum;Kang, Jung-Won;Park, Jin-Yang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.1 s.10
    • /
    • pp.61-64
    • /
    • 2005
  • This study presents a new algorithm to detect the facial feature in a color image entered from the mobile device with complex backgrounds and undefined distance between camera's location and the face. Since skin color model with Hough transformation spent approximately 90$\%$ of running time to extract the fitting ellipse for detection of the facial feature, we have changed the approach to the simple geometric vector operation, called a TS(Triangle-Square) transformation. As the experimental results, this gives benefit of reduced run time. We have similar ratio of face detection to other methods with fast speed enough to be used on real-time identification system in mobile environments.

  • PDF

A Implementation of Smart Band and Data Monitoring System available of Measuring Skin Moisture and UV based on ICT (ICT기반의 피부 수분 및 자외선 측정이 가능한 스마트 밴드 및 데이터 모니터링 시스템 구현)

  • Jung, Se-Hoon;Sim, Chun-Bo;You, Kang-Soo;So, Won-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.715-724
    • /
    • 2017
  • Today all kinds of smart devices are being developed with various researches on wearable devices that support smart computing on the human body. Skin diseases continue to rise including freckles, pimples, atopy, and scalp trouble due to the environmental and genetic factors, and people pay bigger medical bills to treat their skin diseases. There is thus a need to develop a smart-phone or table-based smart healthcare imaging system of high portability and diagnostic accuracy capable of analyzing and managing various skin problems related to skin care. This study proposed an integrated system combining the Smart Mi Band, a wearable device using moisture and UV sensors based on IoT, on the hardware part with the sensor information monitoring software.

Development of the Skin Treatment Unit using Low Temperature Plasma (저온 플라즈마를 이용한 피부치료기 개발에 관한 연구)

  • Song, Kwang-Hyun;Ko, Yon-Seok;Lee, Woo-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1427-1434
    • /
    • 2014
  • Among the medical devices, medical treatments inflicting physical energy from the outside of the body to the inside or using the energy from the devices which take advantages of chemical changes of the human body require a high degree of reliability and safety. In particular, the medical treatment on the most exposed skin to the external surface in all parts of the human body will be very important. In this perspective, when you undergo skin treatment, you need to reduce all risks and to maximize the effect of treatment equipment. Therefore, the development of equipment which guarantees high therapeutic efficacy and safety is essential.

The effect of 470nm LED Irradiation on skin injury of RAT (470nm LED 광이 RAT 피부결손에 미치는 효과)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Shik;Kim, Young-Pyo;Kim, Tae-Gon;Lee, Hee-Keb
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.416-417
    • /
    • 2008
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the 4channel light medical therapy apparatus for external injury cure using a LED light source. This equipment was fabricated by using microcontroller, and designed to enable us to control light irradiation timer, intensity and reservation. In this paper, the designed device was used to find out how 470nm LEDs light source affects the skin wound of RAT. In the experiment, $1cm_2$ wounds on the External injury of RAT were made. Light irradiation RAT and none light irradiation RAT divided, each RAT was irradiated one hour a day for 15 days. In result, compared with none light irradiation RAT, the lower incidence of inflammation and faster recovery was shown in light irradiation RAT.

  • PDF

Face region detection algorithm of natural-image (자연 영상에서 얼굴영역 검출 알고리즘)

  • Lee, Joo-shin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.55-60
    • /
    • 2014
  • In this paper, we proposed a method for face region extraction by skin-color hue, saturation and facial feature extraction in natural images. The proposed algorithm is composed of lighting correction and face detection process. In the lighting correction step, performing correction function for a lighting change. The face detection process extracts the area of skin color by calculating Euclidian distances to the input images using as characteristic vectors color and chroma in 20 skin color sample images. Eye detection using C element in the CMY color model and mouth detection using Q element in the YIQ color model for extracted candidate areas. Face area detected based on human face knowledge for extracted candidate areas. When an experiment was conducted with 10 natural images of face as input images, the method showed a face detection rate of 100%.

Efficient Face Detection based on Skin Color Model (피부색 모델 기반의 효과적인 얼굴 검출 연구)

  • Baek, Young-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.38-43
    • /
    • 2008
  • Skin color information is an important feature for face region detection in color images. This can detect face region using statistical skin color model who is created from skin color information. However, due to the including of different race of people's skin color points, this general statistical model is not accurate enough to detect each specific image as we expected. This paper proposes method to detect correctly face region in various color image that other complexion part is included. In this method set face candidate region applying complexion Gausian distribution based on YCbCr skin color model and applied mathematical morphology to remove noise part and part except face region in color image. And achieved correct face region detection because using Haar-like feature. This approach is capable to distinguish face region from extremely similar skin colors, such as neck skin color or am skin color. Experimental results show that our method can effectively improve face detection results.

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

A new method for mapping visible-near infrared light levels in Fruit

  • Fraser, Daniel G.;Jordan, Robert B.;Kunnemeyer, Rainer;Mcglone, V. Andrew
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1128-1128
    • /
    • 2001
  • We have developed a probe for measuring the light levels inside illuminated fruit. The probe has minimal effect on the light levels being measured and enables the sampling of the light flux at any point within the fruit. We present experimental light extinction rates within apple, nashi, kiwifruit, and mandarin fruit. Moving from the illuminated side to the far side of the fruit, the extinction level follows an initial power law decay as the light diffuses into the fruit then reduces to an exponential decay through the rest of the fruit. Significant variations in the rates of light extinction are found in the core, skin and differing flesh regions. Monte Carlo simulations of the light distribution in fruit, which use scattering and absorption coefficients for the diffusely scattering tissue, and boundary conditions for the skin effects, produce results that follow the experimental results closely.

  • PDF

Microwave Properties of Ag Conducting Paste with Various Preparation Conditions (Ag가 함유된 전도성 도료의 제조 조건에 따른 고주파 특성)

  • Park, Sang-Hoon;Kim, Jeong-Pyo;Seong, Won-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.827-832
    • /
    • 2005
  • Dual band internal antennas were fabricated with Ag conducting paste of various preparation conditions and different print thickness by silk screen print. We have investigated microwave properties were compared Ag conducting paste antenna with copperplate antenna at 800 MHz and 1,800 MHz. Gain of Ag conducting paste antenna was improved when preparation conditions were the single size Ag particle, using dry type resin and high Ag containing percent. However, it was lower than that of copperplate antenna within $0.1\~2.0dBi$ at 800MHz. In addition, it was improved at 800MHz when thickness of Ag conducting paste was printed more than skin depth but it was held after critical print thickness. On the other hand, it was reached level of copperplate antenna at 1,800MHz.