• Title/Summary/Keyword: electronic eye

Search Result 181, Processing Time 0.026 seconds

Autostereoscopic Display System Using a Variable Parallax Barrier (가변형 패럴랙스배리어를 이용한 무안경 디스플레이 시스템)

  • Wi, Sung-Min;Lee, Seung-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.95-102
    • /
    • 2008
  • An advantage of parallax barrier displays is that they can also display 2D and 3D contents and can be automatically switched between the two types. But, as the viewer changes position, different views of the scene will be directed by the barrier to the visual system. Moving horizontally beyond a certain point will produce "image flipping" of the different views of the scene. These limitations make unavoidable the use of another autostereoscopic display solutions like eye tracking or increasing the number of views. In this paper, a method of the moving parallax barrier design is introduced to supplement a disadvantage of the fixed parallax barrier that provides observation at specific locations. For making the moving parallax barrier, the cross connector with 640 lines FPC is designed. A commercially available web camera is utilized to implement eye-tracking system and shows the experimental result.

Real Time Eye and Gaze Tracking (실시간 눈과 시선 위치 추적)

  • Cho, Hyeon-Seob;Kim, Hee-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.195-201
    • /
    • 2005
  • This paper describes preliminary results we have obtained in developing a computer vision system based on active IR illumination for real time gaze tracking for interactive graphic display. Unlike most of the existing gaze tracking techniques, which often require assuming a static head to work well and require a cumbersome calibration process for each person, our gaze tracker can perform robust and accurate gaze estimation without calibration and under rather significant head movement. This is made possible by a new gaze calibration procedure that identifies the mapping from pupil parameters to screen coordinates using the Generalized Regression Neural Networks (GRNN). With GRNN, the mapping does not have to be an analytical function and head movement is explicitly accounted for by the gaze mapping function. Furthermore, the mapping function can generalize to other individuals not used in the training. The effectiveness of our gaze tracker is demonstrated by preliminary experiments that involve gaze-contingent interactive graphic display.

  • PDF

Active Facial Tracking for Fatigue Detection (피로 검출을 위한 능동적 얼굴 추적)

  • Kim, Tae-Woo;Kang, Yong-Seok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.3
    • /
    • pp.53-60
    • /
    • 2009
  • The vision-based driver fatigue detection is one of the most prospective commercial applications of facial expression recognition technology. The facial feature tracking is the primary technique issue in it. Current facial tracking technology faces three challenges: (1) detection failure of some or all of features due to a variety of lighting conditions and head motions; (2) multiple and non-rigid object tracking; and (3) features occlusion when the head is in oblique angles. In this paper, we propose a new active approach. First, the active IR sensor is used to robustly detect pupils under variable lighting conditions. The detected pupils are then used to predict the head motion. Furthermore, face movement is assumed to be locally smooth so that a facial feature can be tracked with a Kalman filter. The simultaneous use of the pupil constraint and the Kalman filtering greatly increases the prediction accuracy for each feature position. Feature detection is accomplished in the Gabor space with respect to the vicinity of predicted location. Local graphs consisting of identified features are extracted and used to capture the spatial relationship among detected features. Finally, a graph-based reliability propagation is proposed to tackle the occlusion problem and verify the tracking results. The experimental results show validity of our active approach to real-life facial tracking under variable lighting conditions, head orientations, and facial expressions.

  • PDF

Effects of Lumbar Mobilization and Transcutaneous Electrical Nerve Stimulation on Proprioception and Muscular Strength in Volleyball Players with Chronic Knee Pain

  • Ahn, Ilhwan;An, Hojung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.12 no.1
    • /
    • pp.2279-2285
    • /
    • 2021
  • Background: The spinal nerves, which start at the lumbar level, are connected to the nerve innervation in the knees. Currently, there is a lack of research on the treatment of knee pain through lumbar mobilization. Objectives: To investigate the effects of lumbar joint mobilization (LJM) and transcutaneous electronic nerve stimulation (TENS) on proprioception and muscular strength in volleyball players with chronic knee pain. Design: Two group pre-posttest. Methods: A total of 26 professional volleyball players with chronic knee pain were allocated to the LJM (n=13) and TENS (n=13) groups. In the LJM group, grade III - IV amplitude was applied 3 times for 1 minute (80 times per minute) at the affected lumbar (L2-3) facet joint in the prone position. In the TENS group, the TENS treatment device was used to directly apply or 15 minutes to the area of chronic knee pain (100 Hz, 150 ㎲). Proprioception was measured by knee flexion and extension angles, and muscle strength was evaluated using an isokinetic test. Measurements were taken before and after interventions. Results: In the eye opened conditiond, proprioception significantly increased during both knee extension and flexion after LJM, while only knee extension was significantly increased in the TENS group. There was also a significant difference in knee extension between the two groups. In the eye close conditiond, proprioception was significantly improved only during knee extension in the LJM group, and the difference in knee extension between the groups was also significant (P<.05). The maximum torque of the affected knee joint was significantly improved at 60°/sec in both groups (P<.05); however, there was no difference between the two groups. There was no significant difference in the maximum flexion torque within or between the groups. Conclusion: This study suggests that LJM improved proprioception and muscular strength in volleyball players with chronic knee pain.

Prediction of Flicker for PDP Devices (플라즈마 디스플레이 패널의 플리커 발생에 대한 예측)

  • Jin Guang-Xu;Kang Sung-Ho;Hong Ki-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.9-18
    • /
    • 2005
  • Flicker is the 'variation in brightness or he perceived won stimulation by intermittent or temporally non uniform light'. This phenomenon is blown as the cause of eye strain and headaches. Many researchers are dedicated to reducing this phenomenon. The flicker phenomenon also exists in PDP as some other display types, and is a critical problem in 50 Hz PDP. However, it is difficult to define flicker by more than one subjective judgment. So, an objective measurement of flicker is necessary and convenient for research on displays. In this paper, a computational prediction model is proposed which is used to predict luminance flicker (not chromatic flicker) by giving a quantitative output that describes the probability of occurrence of flicker. Through this work, we expected to provide a practical tool for flicker-free design in PDP.

Human Detection and Fuzzy Temperature Control System for Energy Reduction of Cooling Device in Elevator (승강기용 냉각장치의 에너지 절감을 위한 사람 검출과 퍼지 온도 제어 시스템)

  • Eum, Hyukmin;Jang, Sukyoon;Lee, Heejin;Park, Mignon;Yoon, Changyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.147-154
    • /
    • 2015
  • In this paper, we propose human detection and fuzzy temperature control system for energy reduction of cooling device in elevator. In order to improve problems of existing cooling device using the refrigerant, energy reduction and efficient management are continuously achieved because of operation of thermoelectric cooling device using the human detection and fuzzy temperature control system. The proposed system confirms the number of passengers in elevator and temperature is then controlled by those numbers and an average temperature for the season in fuzzy system. The human detection method scans the number of passengers using a head part as a feature based on bird's-eye view camera in elevator. The fuzzy system determines elevator internal temperature considering atmospheric temperature and the scanned passenger numbers as a look-up table. The proposed system reduces energy of the cooling device through the human detection and temperature control. In experiment, energy reduction is confirmed and the performance of the proposed system is verified.

Identification of New, Old and Mixed Brown Rice using Freshness and an Electronic Eye (신선도와 전자눈을 이용한 현미 신곡, 구곡 및 혼합곡의 판별)

  • Hong, Jee-Hwa;Park, Young-Jun;Kim, Hyun-Tae;Oh, Sang Kyun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.2
    • /
    • pp.98-105
    • /
    • 2018
  • The sale of brown rice batches composed of rice produced in different years is prohibited in Korea. Thus, new methods for the identification of the year of production are critical for maintaining the distribution of high quality brown rice. Here, we describe the exploitation of an enzyme that can be used to discriminate between freshly harvested and one-year-old brown rice. The degree of enzyme activity was visualized through freshness test with Guaiacol, Oxydol, and p-phenylenediamine reagents. With electronic eye equipment, we selected 29 color codes for identifying new brown rice and old brown rice. The discrimination power of selected color codes showed a minimum of 0.263 to a maximum of 0.922 and an average value of 0.62. The accuracy with which new brown rice and old brown rice could be identified was 100% in principal component analysis (PCA) and discriminant function analysis (DFA). The DFA analysis had greater discriminatory power than did the PCA analysis. A verification test using new brown rice, old brown rice, or a mixture of the two was then performed to validate our method. The accuracy of identification of new and old brown rice was 100% in both cases, whereas mixed brown rice samples were correctly classified at a rate of 96.9%. Additionally, in order to test whether the discriminant constructed in winter can be applied to samples collected in summer, new and old brown rice stored for 8 months were collected and tested. Both new and old brown rice collected in summer were classified as old brown rice and showed 50% identification accuracy. We were able to attribute these observations to changes in enzyme content over time, and therefore we conclude, it will be necessary to develop discriminants that are specific to distinct storage periods in the near future.

A CMOS Image Sensor with Analog Gamma Correction using a Nonlinear Single Slope ADC (비선형 단일 기울기 ADC를 사용하여 아날로그 감마 보정을 적용한 CMOS 이미지 센서)

  • Ham Seog-Heon;Han Gunhee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.65-70
    • /
    • 2006
  • An image sensor has limited dynamic range while the human eye has logarithmic response over wide range of light intensity. Although the sensor gain can be set high to identify details in darker area on the image, this results in saturation in brighter area. The gamma correction is essential to fit the human eye response. However, the digital gamma correction degrades image quality especially for darker area on the image due to the limited ADC resolution and the dynamic range. This Paper proposes a CMOS image sensor (CIS) with a nonlinear analog-to-digital converter (AU) which performs analog gamma correction. The CIS with the proposed nonlinear analog-to-digital conversion scheme was fabricated with a $0.35{\mu}m$ CMOS process. The analog gamma correction using the proposed nonlinear ADC CIS provides the 2.2dB peak-signal-to-noise-ratio(PSM) improved image qualify than conventional digital gamma correction. The PSNR of the image obtain from the digital gamma correction is 25.6dB while it is 27.8dB for analog gamma correction. The PSNR improvement over digital gamma correction is about $28.8\%$.

Effective Eye Detection for Face Recognition to Protect Medical Information (의료정보 보호를 위해 얼굴인식에 필요한 효과적인 시선 검출)

  • Kim, Suk-Il;Seok, Gyeong-Hyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.923-932
    • /
    • 2017
  • In this paper, we propose a GRNN(: Generalized Regression Neural Network) algorithms for new eyes and face recognition identification system to solve the points that need corrective action in accordance with the existing problems of facial movements gaze upon it difficult to identify the user and. Using a Kalman filter structural information elements of a face feature to determine the authenticity of the face was estimated future location using the location information of the current head and the treatment time is relatively fast horizontal and vertical elements of the face using a histogram analysis the detected. And the light obtained by configuring the infrared illuminator pupil effects in real-time detection of the pupil, the pupil tracking was to extract the text print vector. The abstract is to be in fully-justified italicized text as it is here, below the author information.

Effects of Tai Chi on Balance and Muscle Activity of Ankle Joints with USN sensor in Elderly People (태극권이 노인의 균형과 센서 USN을 이용한 발목관절 근활성도에 미치는 영향)

  • Kang, Jeong-Il;Kwon, Hye-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.425-431
    • /
    • 2015
  • The objective of this study was to effect of Tai Chi on balance and muscle activity of ankle joints with USN sensor in elderly people. Thirty six elderly participated and randomly assigned to a experimental group with Tai Chi and control group. The experimental group trained using a Tai Chi through 3 times per a week over 6 weeks. For all subjects, their balance such as functional reach test and one leg stance test, the change of muscle activity of ankle joints with USN sensor wireless-electromyogram during leg closed stance with eye closed were measured, and the results were as followed. The results were of a signigicant changes to the balance in group and between group as well. Comparison of muscle activity left tibialis anterior and left gastrocnemius in group, there were significant difference. Comparison of muscle activity right tibialis anterior and right gastrocnemius in group, there were significant difference. Comparison of muscle activity between groups, there was significant difference. Additional results indicated that, elderly people who received Tai Chi in one study, improve balance control and muscle activity ankle joint. so it is anticipated that improvement in clinical utilization for the elderly who's gait ability and balance ability reduced.