• Title/Summary/Keyword: electron transport complex

Search Result 62, Processing Time 0.023 seconds

Chloroplastic NAD(P)H Dehydrogenase Complex and Cyclic Electron Transport around Photosystem I

  • Endo, Tsuyoshi;Ishida, Satoshi;Ishikawa, Noriko;Sato, Fumihiko
    • Molecules and Cells
    • /
    • v.25 no.2
    • /
    • pp.158-162
    • /
    • 2008
  • Recent molecular genetics studies have revealed that cyclic electron transport around photosystem I is essential for normal photosynthesis and growth of plants. Chloroplastic NAD(P)H dehydorgenase (NDH) complex, a homologue of the complex I in respiratory electron transport, is involved in one of two cyclic pathways. Recent studies on the function and structure of the NDH complex are reviewed.

Effetcs of Hexavalent Chromium on the Mitochondrial Electron Transport System in Mouse Liver (생쥐 간세포 Mitochondria의 전자전달계에 미치는 Chromium(VI)의 영향)

  • Boo, Moon-Jong;Yoo, Chang-Kyu;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.17 no.1
    • /
    • pp.29-46
    • /
    • 1987
  • To study hexavalent chromium effects on mitochondrial electron transport, the activities of electron transport enzymes and conformational change of mitochondria treated with $40{\mu}M$ of sodium dichromate ($Na_{2}Cr_{2}O_{7}\;2H_{2}O$) were investigated. And so were those of liver mitochondria isolated from mouse intraperitoneally injected with sodium dichromate, 40mg per kg body weight. On both treatment with chromium(VI), the activities of electron transfer enzymes (Complex I and IV) were increased to some extent and the ultrastructural transformation of mitochondria from a condensed to an orthodox conformation was inhibited under State IV respiration. These results represent' inhibitory effect of hexavalent chromium on electron transport without inhibiting electron transfer enzymes (Complex I and IV) in mitochondria. On intraperitoneal treatment with hexavalent chromium as sodium dichromate and trivalent chromium as chromic chloride, containing 37.5 mg of chromium per kg body weight, respectively, the activities of electron transfer enzymes of liver isolated from mouse with chromium(VI) was reduced, but that with chromium(III) was not affected. And with chromium(VI), all mice after 12 hours of treatment died, only after 6 hours survived. With chromium(III), however, all survived. This indicates that hexavalent chromium is more toxic than trivalent chromiumin mouse liver.

  • PDF

Changes of Chloroplast-Mediated Electron Transport Activity and Chlorophyll-Protein Complexes in Barley Seedlings by Decursinol (Decursinol 처리에 따른 보리 유식물의 전자전달 활성과 엽록소-단백질 복합체의 변화에 대하여)

  • 이현식
    • Journal of Plant Biology
    • /
    • v.31 no.2
    • /
    • pp.131-141
    • /
    • 1988
  • The effects of decursinol and decursin on chloroplast-mediated electron transport and phosphorylation in barley seedlings were investigated in comparison with coumarin in the dark or light. The changes of CP-complexes were also studied. Decursinol, decursin and coumarin caused marked inhibitory effects on germination of seed and electron transport and phosphorylation activity of seedlings. The following order of inhibitory effectiveness was exhibited; decursinol>coumarin>decursin. Loss of chlorophyll and decrease of electron transport activity were retarded in the dark, but were reversely accelerated in the light by these three chemicals. The changes of CP-complex patterns were also similar to effects on chlorophyll content and the electron transport activity. These opposite effect in the dark and light suggest that these three chemicals act as natural growth retardants rather than cytokinins or growth inhibitors.

  • PDF

Electron Transport Properties of Zn(phen)q Compared with Alq3 in OLED

  • Kim, Byoung-Sang;Kim, Dong-Eun;Choi, Gyu-Chae;Park, Jun-Woo;Lee, Burm-Jong;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.418-422
    • /
    • 2009
  • We synthesized new electroluminescence materials [(1,10-phenanthroline)(8-hydroxyquinoline)] Zn(phen)q and investigated their electron transport properties. We used Zn(phen)q and $Alq_3$ for the conductive materials and measured their electron transport properties as a function of the organic layer thickness. The difference between Zn(phen)q and $Alq_3$ as electron transporting materials suggests that the electrical properties depends on the carrier injection.

Effects of Local Anesthetics on Electron Transport and Generation of Superoxide Radicals in Mitochondria (국소마취제가 Mitochondria에서의 전자이동 및 Superoxide Radicals의 생성에 미치는 영향)

  • Lee, Chung-Soo;Shin, Yong-Kyoo;Lee, Kwang-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 1987
  • Local anesthetics were investigated for their effects on mitochondrial electron transport system, production of superoxide radical from submitochondrial particles and malondialdehyde production through lipid per oxidation. Local anesthetics had various effects on activities of enzymes in electron transport chain. The activities of NADH dehydrogenase, NADH oxidase and NADH-ubiquinone oxidoreductase were effectively inhibited by lidocaine, procaine and dibucaine but slightly influenced by cocaine. The activities of succinate dehydrogenase, succinate-cytochrome c oxidoreductase and succinate-ubiquinone oxidoreductase were inhibited by lidocaine and dibucaine, but the succinate oxidase activity was stimulated by local anesthetics. Both dihydroubiquinone-cytochrome c oxidoreductase and cytochrome c oxidase activities were inhibited by local anesthetics. In these reactions, the response of Complex I segment to local anesthetics was greater than other Complex segments. Local anesthetics inhibited both the superoxide production from submitochondrial particles supplemented with succinate or NADH and the enhanced production of superoxide radicals by antimycin. The malondialdehyde production by oxygen free radicals was inhibited by local anesthetics. These results suggest that the inhibition of superoxide and malondialdehyde production caused by local anesthetics may be brought by suppression of the electron transport in mitochondria at sites in or near complex I segment.

  • PDF

Formation of Chlorophyll-Protein Complexes in Greening Rape Cotyledons (Greening에 따른 유채 자엽의 엽록소-단백질 복합체 형성)

  • 이진범
    • Journal of Plant Biology
    • /
    • v.26 no.2
    • /
    • pp.91-99
    • /
    • 1983
  • The formation of chlorophyll-protein complexes (CP-complexes) during the greening of rape cotyledons (Brassica napus cv. Yongdang) was investigated by the SDS-polyacrylamide gel electrophoresis. The total chlorophyll content and Chl a/b ratio were also determined. In addition, the effects of dark treatment on the CP-complex patterns during greening have been examined with respect to their photosynthetic electron transport activity. Greening has brought about the increasein total chlorophyll content and the decrease in Chl a/b ratio, but there have been no changes in Chl a/b ratio after 24 hrs of greening. The light-harvesting chlorophyll a/b-protein complex (LHCP-complex0 was predominant during the initial greening period. Thereafter, the amout of chlorophyll a-protein complex (CP I-complex) was gradually increased. Twenty-four-hr dark treatment immediately after illumination for 6 hrs and 12 hrs resulted in the increase of the Chl a/b ration and the CP I complex, otherwise the decrease of the LHCP-complex. The LHCP/CP I ratio was gradually decreased with further greening, and appeared no change after 48 hrs illumination. The investigation of the photosynthetic electron transport activity indicated that photosystem (PS) II activity (H2Olongrightarrowp-PD*+FeCy**) did not change, but the activity of PS I was increased suddenly due to the dark treatment. The data suggests that the increase of CP I-complex may result in that of P-700, that is, the increase of PS I activity.

  • PDF

The Study of Luminescence Efficiency by change of OLED's Hole Transport Layer

  • Lee, Jung-Ho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.52-55
    • /
    • 2006
  • The OLEDs(Organic Light-Emitting Diodes) structure organizes the bottom layer using glass, ITO(indium thin oxide), hole injection layer, hole transport layer, emitting material layer, electron transport layer, electron injection layer and cathode using metal. OLED has various advantages. OLEDs research has been divided into structural side and emitting material side. The amount of emitting light and luminescence efficiency has been improved by continuing effort for emitting material layer. The emitting light mechanism of OLEDs consists of electrons and holes injected from cathode and anode recombination in emitting material layer. The mobilities of injected electrons and holes are different. The mobility of holes is faster than that of electrons. In order to get high luminescence efficiency by recombine electrons and holes, the balance of their mobility must be set. The more complex thin film structure of OLED becomes, the more understanding about physical phenomenon in each interface is needed. This paper observed what the thickness change of hole transport layer has an affection through the below experiments. Moreover, this paper uses numerical analysis about carrier transport layer thickness change on the basis of these experimental results that agree with simulation results.

Effects of Lead on the Ultrastructure ana the Electron Transport System of Mitochondria of Mouse Kidney (납(Pb)이 생쥐 신장세포에 미토콘드리아 미세구조 및 전자전달계에 미치는 영향)

  • Lim, Seung-Sub;Yoo, Chang-Kyu;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.17 no.2
    • /
    • pp.55-71
    • /
    • 1987
  • To investigate the effects of lead on the electron transport system and ultrastructure of mouse kidney mitochondria, various lead acetate concentrations were treated in vitro and respiration rate, enzyme activities were measured. Ultrastructural changes at state IV respiration were also observed. To compare with in vivo experiments, mouse were injected intraperitoneally of 100 mg lead acetate per kg body weight and state IV respiration rate and enzyme activities were measured. Ultrastructure of renal proximal tubular cells were also observed. In in vitro treatement, decreased state IV respiration, decreased enzyme activities, ruptured membranes and inhibition of condensed to orthodox transformation were observed. In in vivo treatment, decreased state IV respiration and decreased enzyme activities were observed after 24 hrs of i.p. injection. Cytochrome c oxidase activity showed twice the inhibition compared to NADH-CoQ reductase activity at 24 hrs. Continuous decreased state IV respiration was observed after 48 and 72 hrs of injection, however, the enzyme activities were increased to control level. Lead-protein complex which probably inhibits the toxic effects of lead appeared. To conclude, dominant effect of lead on the electron transport system appeared at cytochrome c oxidase activity, and the increased enzyme activities may be a result of appearance of lead-protein complex.

  • PDF

Blue-green Electroluminescence from Aluminum and ${\alpha}$-pyridoin Complex

  • Kim, Won-Sam;Lee, Burm-Jong;Tuong, Nguyen Manh;Son, Eun-Mi;Yang, Ki-Sung;Kwon, Young-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.605-608
    • /
    • 2004
  • A novel blue-green emitting aluminum complex was developed by employing 8-hydroxyquinoline as co-ligand for enhancement of electron transport and light emission abilities so that the electroluminescent (EL) devices do not need additional electron transport layer. The aluminum complex (PAlQ) of 8-hydroxyquinoline and ${\alpha}$-pyridoin was synthesized The structure of the PAlQ was elucidated by FT-IR, UV-Vis and XPS. The PAlQ complex showed thermal stability up to 350$^{\circ}C$ under nitrogen flow by TGA. The photoluminescence (PL) was measured from solid film of the PAlQ complex on quartz substrate. The EL device was fabricated by the vacuum deposition. The device having the structure of ITO/TPD/PAlQ/Al was studied, where N,N-bis(3-methylphenyl}-N,N'-diphenyl-benzidine (TPD) was used as a hole transporting layer. The EL device emitted a blue-green light.

  • PDF

Improved Electron Injection on Organic Light-emitting Diodes with an Organic Electron Injection Layer

  • Kim, Jun-Ho;Suh, Chung-Ha;Kwak, Mi-Young;Kim, Bong-Ok;Kim, Young-Kwan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.221-224
    • /
    • 2005
  • To overcome of poor electron injection in organic light-emitting diodes (OLEDs) with Al cathode, a thin layer of inorganic insulating materials, like as LiF, is inserted between an Al cathode and an organic electron transport layer. Though the device, mentioned above, improves both turn on voltage and luminescent properties, it has some problems like as thickness restriction, less than 2 nm, and difficulty of deposition control. On the other hand, Li organic complex, Liq, is less thickness restrictive and easy to deposit and it also enhances the performance of devices. This paper reports the improved electron injection on OLEDs with another I A group metal complex, Potassium quinolate (Kq), as an electron injection material. OLEDs with organic complexes showed improved turn-on voltage and luminous efficiency which are remarkably improved compared to OLEDs with Al cathode. Especially, OLEDs with Kq have longer life time than OLEDs with Liq.