• Title/Summary/Keyword: electron sources

Search Result 312, Processing Time 0.031 seconds

Long-term Testing and Analysis of a ScSZ/LaSrCuFe Cell

  • Wackerl, Jurgen;Peck, Dong-Hyun;Markus, Torsten
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.788-795
    • /
    • 2008
  • An electrolyte supported SOFC cell was tested at $800^{\circ}C$ in air for 3600 h with an applied current density of $200\;mA/cm^2$ to examine possible cathode degradation issues. A scandium- stabilized zirconia (ScSZ) with additional manganese doping (ScSZ: Mn) was used as electrolyte. A strontium and copper-doped lanthanum ferrite (LaSrCuFe) and platinum were used as cathode and quasi-anode material, respectively. The DC resistance was logged over the complete testing period. Additionally, impedance spectroscopy was used from time to time to track changes of the cell in-situ. Post-test analysis of the cell using methods like scanning electron microscopy imaging and other electrochemical testing methods allow the identification of different degradation sources. The results indicate a promising combination of electrolyte and cathode material in terms of chemical compatibility and electrical performance.

Calculation of the Quantum Efficiency of Phosphor Screens in CRTs and FL Tubes

  • Ozawa, Lyuji;Tian, Yakui
    • Journal of Information Display
    • /
    • v.11 no.3
    • /
    • pp.128-133
    • /
    • 2010
  • The quantum efficiencies of CRT and FL tubes that use a phosphor screen as transducer of invisible particles to light in visible spectrum wavelengths were calculated in this study. The phosphor screens in CRT tubes have quantum efficiencies greater than 3,000, which give the luminance of comfortable images on phosphor devices for the observation by the eyes. The established FL tubes have the amazing quantum efficiency of $3{\times}10^{10}$ photons per moving electron per FL tube, which allows the illumination of a $5{\times}5\;m^2$ room by three FL tubes, with heating at $40^{\circ}C$. Thus, FL tubes, including for backlighting of LCD displays, have a superior over other illumination sources.

PECVD of Blanket $TiSi_2$ on Oxide Patterned Wafers (산화막 패턴 웨이퍼 위에 플라즈마 화학증착법을 이용한 균일 $TiSi_2$ 박막형성에 관한 연구)

  • Lee, Jaegab
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.153-161
    • /
    • 1992
  • A plasma has been used in a high vaccum, cold wall reactor for low temperature deposition of C54 TiSi2 and for in-situ surface cleaning prior to silicide deposition. SiH4 and TiCl4 were used as the silicon and titanium sources, respectively. The deposited films had low resistivities in the range of 15~25 uohm-cm. The investigation of the experimental variables' effects on the growth of silicide and its concomitant silicon consumption revealed that and were the dominant species for silicide formation and the primary factors in silicon consumption were gas composition ratio and temperature. Increasing silane flow rate from 6 to 9 sccm decreased silicon consumption from 1500 A/min to less than 30 A/min. Furthermore, decreasing the temperature from 650 to $590^{\circ}C$ achieved blanket silicide deposition with no silicon consumption. A kinetic model of silicon consumption is proposed to understand the fundamental mechanism responsible for the dependence of silicon consumption on SiH4 flow rate.

  • PDF

Determination of N. N-dimethylaniline in penicillins by GC-MS

  • Choi, Jung-Kap;Park, Man-Ki
    • Archives of Pharmacal Research
    • /
    • v.4 no.2
    • /
    • pp.85-90
    • /
    • 1981
  • A quantitative GC-MS spectrometric assay was used for the determination of residual N, N-dimethylaniline as a contaminant in commercial penicillin derivatives from various sources. The assay utilizes selective ion focusing to monitor in a GC effluent the molecular ions of DMA generated by electron impact ionization. This method includes dissolution of the sample in alkaline solution, extraction of organic base with cyclohexane and injection into GC-MS with a 3% OV-17 column. Levels of 50 ppb of DMA were easily measured with a coeffecient of varation less than 5 % and recoveries from spiked samples exceeded 97 %. The results of the determinations of DMA in various commercial penicillins were relatively free of this contaminant.

  • PDF

A Study on the High Selective Oxide Etching using Inductively Coupled Plasma Source (유도결합형 플라즈마원을 이용한 고선택비 산화막 식각에 관한 연구)

  • 이수부;박헌건;이석현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.261-266
    • /
    • 1998
  • In developing the high density memory device, the etching of fine pattern is becoming increasingly important. Therefore, definition of ultra fine line and space pattern and minimization of damage and contamination are essential process. Also, the high density plasma in low operating pressure is necessary. The candidates of high density plasma sources are electron cyclotron resonance plasma, helicon wave plasma, helical resonator, and inductively coupled plasma. In this study, planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, flow rate, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

Effective Carbon Coating on $LiFePO_4$ Using Petroleum Pitch (석유 핏치를 이용한 $LiFePO_4$의 효율적인 탄소 코팅방법)

  • Lee, Jae-Won;Oh, Chi-Hoon;Park, Sun-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.303-304
    • /
    • 2007
  • A comparison study of carbon coating on $LiFePO_4$ was done with two different carbon sources-petroleum pitch and Ketjen black. Raman spectroscopy and transmission electron microscopy (TEM) analysis were applied to the carbon-coated $LiFePO_4$. $LiFePO_4$ which was carbon-coated with petroleum pitch showed more uniform carbon layer and ordered carbon structure. Such uniformity and ordered structure of carbon coating layer resulted in higher initial discharge capacity and better rate capability.

  • PDF

The Effect of Crystal and Non-Crystal Structures on Shielding Material Behaviour Under A.C. Field Excitations

  • Rahman, Nazaruddin Abd;Mahadi, Wan Nor Liza
    • Journal of Magnetics
    • /
    • v.18 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • Shielding effects in conductive and magnetic materials were investigated as a function of properties, thickness and diameter. In this work, evaluations on passive conductive and magnetic shield specimens were achieved through experimentation set-up using 50 Hz single and three phase induction field sources. Analysis on material microstructure properties and characteristics of shielding specimens were performed with the use of vibrating sample magnetometer (VSM) and field emission scanning electron microscopy (FESEM). An induction field at $136{\mu}T$ of single phase system and $50{\mu}T$ of three phase systems were observed to the shield specimens with the thickness ranged of 0.2 mm to 0.4 mm. It is observed that shield specimen efficiency becomes inversely proportionate to the increment of induction fields. The decrease was attributed to the surface structure texture which relates to the crystallization and non-crystallization geometrical effects.

Analysis of Deposited Dust Particles using SEM/EDX (SEM/EDX 분석법을 이용한 침착먼지에 대한 분석사례)

  • Ha, Eun-Ji;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.30 no.3
    • /
    • pp.279-287
    • /
    • 2021
  • In this study, the composition and morphology of deposited dust particles with size ranging from a few to tens ㎛ were investigated using SEM/EDX (scanning electron microscopy with energy dispersive x-ray spectrometer). Then deposited dust particles were classified into 8 groups: quartz, aluminosilicates, ca-rich, Fe/Ti oxide, carbon-rich, industrial particle, Fe-rich, and biogenic particle. The sources of deposited dust were high in the order of aluminosilicates 41% > biogenic 18% > Fe-rich 11% > quartz and C-rich 8% > industrial 7% > Fe/Ti oxide 5% > Ca-rich 1%. In particular, the ratio of biogenic particles was relatively high due to influence of pollen. The ratio of carbon-rich was 11% at YM site, 10% at MD site, and 4% at MO site, and the site close to the large emission source was high.

Green Synthesis of Dual Emission Nitrogen-Rich Carbon Dot and Its Use in Ag+ Ion and EDTA Sensing

  • Le Thuy Hoa;Jin Suk Chung;Seung Hyun Hur
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.463-471
    • /
    • 2023
  • Nitrogen-rich carbon dots (NDots) were synthesized by using uric acid as carbon and nitrogen sources. The as-synthesized NDots showed strong dual emissions at 420 nm and 510 nm with excitation at 350 nm and 460 nm, respectively. The physicochemical analyses such as X-ray photoelectron spectroscopy, Transmission electron microscopy and Fourier transform infrared spectroscopy were used to analyze the chemical, physical and morphological structures of NDots. The as-synthesized NDots exhibited wide linear range (0-100 µM) and very low detection limit (124 nM) in Ag+ ion sensing. In addition, Ag+ saturated NDots could be used as an EDTA sensor by the EDTA induced PL recovery.

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.