• 제목/요약/키워드: electron sources

검색결과 306건 처리시간 0.024초

Oxide Cathodes for Reliable Electron Sources

  • Weon, Byung-Mook;Je, Jung-Ho;Park, Gong-Seog;Koh, Nam-Je;Barratt, David S.;Saito, Tsunenari
    • Journal of Information Display
    • /
    • 제6권4호
    • /
    • pp.35-39
    • /
    • 2005
  • In this paper, we investigate the oxide cathodes for the development of reliable electron sources. Poisoning in oxide cathodes is one of the serious problems in achieving reliable electron emission. In particular, early poisoning induces poor life performance as will be demonstrated herein. The survivability of electron emission sources is significantly improved by high doping of high-speed activator. The robust oxide cathodes with 0.17 % Mg operating at about 1,050 K are expected to work for very long times (>100,000 hours). We suggest that this key idea will contribute to solving the basic problems in oxide cathodes such as poisoning or ion bombardment for high power or high frequency applications of electron sources.

New electron source and electron collection source for the internal electron circuit in FL tubes

  • Ozawa, Lyuji;Tian, Yakui;Kato, Masatoshi
    • Journal of Information Display
    • /
    • 제12권2호
    • /
    • pp.69-75
    • /
    • 2011
  • A new electron source and an electron collection source were found for the closure of the internal electron circuit inside fluorescent lamp (FL) tubes. The sources are formed in front of the polarized electric-insulator particles on the metal electrodes at both ends of the FL tube. The appearance and disappearance of both sources are controlled by the electric voltages applied to the metal electrodes. The electrons and $Ar^+$ for the sources are generated by the ionization of the Ar atoms, and they return to the Ar atoms at the electron collection source. Thus, the Ar atoms are preserved in the FL tubes, ensuring a long operation life for such tubes.

전자현미경의 전자원 (Electron sources for electron microsocpes)

  • 조복래
    • 진공이야기
    • /
    • 제2권2호
    • /
    • pp.24-28
    • /
    • 2015
  • The brightness of an electron source, along with the aberrations of an objective lens, determines the image resolution and beam current on samples, which are two important parameters for evaluating the performance of an electron microscope. Here we introduce thermal electron source, Schottky emitter and cold field electron emitter. Thermal electron source is the cheapest and stable electron source but it has the lowest brightness. Schottky emitter is 10000 times brighter than tungsten thermal electron source, but requires ultrahigh vacuum operating condition. Cold field electron emitter is 10 times brighter than Schottky emitters, but it is rather unstable and its operation requires most stringent vacuum condition, hindering its widespread use.

전도성 고분자 나노튜브와 나노와이어: 합성 및 특성, 트랜지스터와 전계방출 나노 팁에서의 응용 (Conducting Polymer Nanotube and Nanowire: Synthesis, Characteristics, and Applications to Transistor and Field Emission Nano-tip)

  • Joo J.;Kim B.H.;Park K.T.;Kim M.S.;Lee S.Y.;Jeong C.J.;Lee J.K.;Park D.H.;Kim K.G.;Jin J.I.;Yu S.G.;Lee S.H.;Yi W.K.
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2002년도 추계총회 및 학술발표회
    • /
    • pp.26-26
    • /
    • 2002
  • PDF

Development of High-Sensitivity Ion Sources for Residual Gas Analyzer

  • 박창준;한철수;안상정
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.104.2-104.2
    • /
    • 2013
  • A residual gas analyzer (RGA) system has been developed in this laboratory. Characteristics of the RGA system parts such as ion source, quadrupole mass filter and sensitivity are introduced. Some efforts have been made to improve performance of the two types of ion sources, open ion source (OIS) and closed ion source (CIS). A metal mesh was placed onto the electron beam entrance of the CIS anode tube to block the filament field penetration. Sensitivity of the CIS ion sources with and without the mesh was compared by mass spectra of SF6 gas (97% He base) introduced into the CIS anode through a needle valve. About ten-times improvement in the RGA sensitivity was observed for the CIS with the mesh in the electron entrance. Computer simulation showed an axi-symmetric anode potential distribution and improved focusing of the electron beam inside the anode tube with the mesh.

  • PDF

Fabrication and characterization of a carbon nanotube-based point electron source

  • Choi, Ha-Kyu;Kim, G.Y.;Song, Y.I.;Jeong, H.J.;Lim, S.C.;Lee, Y.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1536-1537
    • /
    • 2005
  • We have made point electron sources using carbon nanotubes (CNTs). For the fabrication of point electron sources, CNTs were dispersed in a solution and attached on electrochemically etched W tips using electrophoresis. In our study, we have utilized various CNTs such as single-walled CNT (SWCNT), multiwalled CNT (MWCNT), and thin-MWCNT and threshold current, turn-on voltage, filed enhancement factor of each emitter have been studied upon a tube/bundle diameter and length. In addition, fieldemitted electron energy distribution of various CNT emitters is characterized.

  • PDF

Characterizations of Denitrifying Polyphosphate-accumulating Bacterium Paracoccus sp. Strain YKP-9

  • Lee, Han-Woong;Park, Yong-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권12호
    • /
    • pp.1958-1965
    • /
    • 2008
  • A denitrifying polyphosphate-accumulating bacterium (YKP-9) was isolated from activated sludge of a 5-stage biological nutrient removal process with step feed system. This organism was a Gram-negative, coccus-shaped, facultative aerobic chemoorganotroph. It had a respiratory type of metabolism with oxygen, nitrate, and nitrite as terminal electron acceptors. The 16S rRNA gene sequence of strain YKP-9 was most similar to the 16S rRNA gene sequence of Paracoccus sp. OL18 (AY312056) (similarity level, 97%). Denitrifying polyphosphate accumulation by strain YKP-9 was examined under anaerobic-anoxic and anaerobic-oxic batch conditions. It was able to use external carbon sources for polyhydroxyalkanoates(PHA) synthesis and to release phosphate under anaerobic condition. It accumulated polyphosphate and grew a little on energy provided by external carbon sources under anoxic condition, but did neither accumulate polyphosphate nor grow in the absence of external carbon sources under anoxic condition. Cells with intracellular PHA cannot accumulate polyphosphate in the absence of external carbon sources under anoxic condition. Under oxic condition, it grew but could not accumulate polyphosphate with external carbon sources. Based on the results from this study, strain YKP-9 is a new-type denitrifying polyphosphate-accumulating bacterium that accumulates polyphosphate only under anoxic condition, with nitrate and nitrite as the electron acceptors in the presence of external carbon sources.

POLARIZATION OBSERVATIONS OF BACKGROUND RADIO SOURCES SEEN THROUGH THE SUPERNOVA REMNANT S 147

  • Kim, Kwang-Tae
    • 천문학회지
    • /
    • 제21권2호
    • /
    • pp.133-153
    • /
    • 1988
  • Linear polarization has been measured for fifteen extragalactic radio sources in the field of supernova remnant S 147. These observations were made at 4885, 4835, 1665, 1515, 1465, and 1385 MHz using the Very Large Array, primarily to determine unambiguous Rotation Measures (RM) of the sources. This yields a total of 11 new RM sources. Comparisons of a sample of sources which are seen through S 147 were made with sources located farther away. The result tentatively indicates that the distribution of the rotation measure of the former population is broadened, with more than a 85% level of confidence. This constitutes evidence that there is a SNR contribution to rotation measure in sources seen through the SNR. Limits on this RM contribution are statistically at 30 < | RM | < 70 rad $m^{-2}$ with a 85% statistical level of confidence. These result imply the magnetic field in the rim of S 147 has strength 10 microguass if the electron density is $1\;cm^{-3}$.

  • PDF

Quality Evaluation of Sliced and Pizza Cheeses Treated by Gamma and Electron Beam Irradiation

  • Kim, Hyun-Joo;Ham, Jun-Sang;Kim, Kee-Hyuk;Ha, Ji-Hyoung;Ha, Sang-Do;Jo, Cheo-Run
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권8호
    • /
    • pp.1112-1117
    • /
    • 2010
  • This study was conducted to evaluate and compare the quality changes of commercial sliced and pizza cheeses processed by gamma and electron beam irradiation. The $L^*$-value of sliced and pizza cheeses decreased and the $a^*$-value decreased only in pizza cheese by both irradiation sources. There was no change in pH. There was no difference in 2-thiobarbituric acid reactive substances (TBARS) value between non-irradiated and irradiated samples at a dose of 3 kGy or less (p<0.05). However, both irradiation sources resulted in increased TBARS value in sliced and pizza cheeses at 5 kGy. Sensory evaluation revealed that irradiation influenced odor, taste and overall acceptability of both cheeses and may cause the limitation of consumers' acceptance for irradiated cheese products. Results indicate that both gamma and electron beam irradiations with less than 3 kGy may not influence significantly the physicochemical quality of sliced and pizza cheeses. However, to meet a market requirement, a method to overcome the sensory deterioration of cheeses should be developed and applied.

자유전자레이저의 개발현황과 전망 (Status and Prospect of Free Electron Lasers)

  • 이병철;정영욱;박성희;한상준
    • 한국진공학회지
    • /
    • 제15권5호
    • /
    • pp.435-450
    • /
    • 2006
  • 자유전자레이저는 고에너지 전자빔의 운동에너지를 빛 에너지로 바꾸는 장치로서, 다른 어떤 종류의 광원으로도 제공할 수 없는 넓은 범위의 파장가변성과 우수한 분광특성을 갖고 있어, 기초연구에서부터 산업응용에 이르기까지 다양하게 활용될 수 있을 것으로 기대된다. 이 논문에서는 자유전자레이저의 원리와 특성, 요소기술을 소개하고, 최근 주목받고 있는 테라헤르츠파 자유전자레이저와 에너지 회수형 고출력 자유전자레이저에 대하여 자세하게 소개하였다.