• Title/Summary/Keyword: electron microscopic analysis

Search Result 222, Processing Time 0.026 seconds

Variations in electrode characteristics through simplification of phosphorus-doped NiCo2O4 electrode manufacturing process (인이 도핑된 NiCo2O4 전극 제조 공정의 간소화를 통한 전극 특성의 변화)

  • Seokhee-Lee;Hyunjin Cha;Jeonghwan Park;Young Guk Son;Donghyun Hwang
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.5
    • /
    • pp.299-308
    • /
    • 2023
  • In this study, phosphorus (P)-doped nickel cobaltite (P-NiCo2O4) and nickel-cobalt layered double hydroxide (P-NiCo-LDH) were synthesized on nickel (Ni) foam as a conductive support using hydrothermal synthesis. The thermal properties, crystal structure, microscopic surface morphology, chemical distribution, electronic state of the constituent elements on the sample surface, and electrical properties of the synthesized P-NiCo2O4 and P-NiCo-LDH samples were analyzed using thermogravimetric analysis-differential scanning calorimetry (TGA-DSC), X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), galvanostatic charge-discharge (GCD), and electrochemical impedance spectroscopy (EIS). The P-NiCo2O4 electrode exhibited a specific capacitance of 1,129 Fg-1 at a current density of 1 Ag-1, while the P-NiCo-LDH electrode displayed a specific capacitance of 1,012 Fg-1 at a current density of 1 Ag-1. When assessing capacity changes for 3,000 cycles, the P-NiCo2O4 electrode exhibited a capacity retention rate of 54%, whereas the P-NiCo-LDH electrode showed a capacity retention rate of 57%.

GC-MASS Analysis and Microbial Enumeration for the Identification of Spoiled Red Pepper Powder (GC-MASS 분석과 미생물 균수 차이에 의한 희아리 고춧가루 판별)

  • Jeong, Su-Jin;Han, Sang-Bae;Uhm, Tai-Boong
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • This work was intended for the identification of markers that are found only in the spoiled red pepper powder. When analyzed by GC/MASS, the spoiled red pepper powder contains characteristic naphthalene derivatives, 1, 2, 3, 5, 6, 7, 8, $8\alpha$-octahydro-1, $8\alpha$-dimethyl-7-(1-methylethenyl)-naphthalene and 2-isopropenyl-$4\alpha$, 8-dimethyl-1, 2, 3, 4, $4\alpha$, 5, 6, $8\alpha$-octahydronaphthalene, which have not found in the normal red pepper powder. In addition, microscopic observation and microbial enumeration of the red pepper powder had been performed. Images by scanning electron microscopy showed that the surfaces of spoiled pepper powder were rough with many kinds of microbes, compared with those of normal red pepper powder. A good correlation between the bacterial and fungal counts in the same sample was observed and could be clearly classified into two groups, the normal and the spoiled group, by difference in the microbial counts. These results suggest that the spoiled red pepper powder can be identified by a combination of GC/MASS, microbial counts, and scanning electron microscopy.

BIOLOGICAL EFFECTS OF pH CONCENTRATION ON CULTURED HUMAN PERIODONTAL LIGAMENT CELL ACTIVITY IN VITRO (수소이온 농도의 변화가 배양 인체 치주인대 세포의 활성에 미치는 영향)

  • Kim, Seong-Ho;Park, Kui-Woon;Yoo, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.539-556
    • /
    • 1995
  • Periodontal therapeutic modalities should be re-establishing and regenerating the periodontal tissue previously lost to the disease. To achieve periodontal regeneration, periodontal ligament cells must selective migrate to the deneded root surface, attached and proliferated it. Local pH concentration is one of the most factors that periodontal regeneration. The aims of this study were to examine on biological effects of pH to the human periodontal ligament cells in vitro, especially on the cell morphology, attachment, activity, vitality and viability. Human periodontal ligament cells were cultured from extracted tooth for non-periodontal reason. Immediately after extraction, any soft tissue adhering to the cervical parts of the roots was carefully removed with a sterile curette. To produce different pH levels in the media, Eagle's MEM was adjusted from pH 6.6 to 8.2 in 0.2 intervals with 1 M NaOH and 1 N HCl. After cultivation, Then, Periodontal ligament cells were cultured at pH ranging from 6.6-8.2. attachment assay was done at 1, 2 day incubation and activity assay was done at 1, 2, 3 day incubation. The experiments were evaluated by scaning electron microscopic techniques (HITACHIX-650 Scaning Electron Microanalyzer, Tokyo, Japan), MTT assay, and the cultured periodontal ligament cells were fixed in neutral formalin for 24 hours and immunohistochemically processed by PCNA for proliferating ability. The surviving cells in the medium showed slightly increased volume and widening intercellular distances at low concentration of pH than control group (pH 7.4), and apparently shrinkage at high concentration of pH than control group (pH 7.4). The results of the statistical analysis from the experiment on attachment, vitality and viability were as follows. Attachment of periodontal ligament cells at 1st and 2nd day, similar attachment rate of low concentration pH compared with control value (pH 7.4). But above pH 8.0, attachment rate were statistically significant decrease from control value(P<0.05). Periodontal ligament cell's activities were maximum at pH 7.6 by MTT assay. Similar with control value at low concentration of pH. But, the activities were statistically significant decrease at high concentraration of pH(P<0.05). Cellular proliferating rate (PCNA index) were statistically significant decrease from control value at low and high concentration of pH(p<0.05). This results suggested that hjgh concentration pH, in other words, alkali pH was cytotoxic effects on human periodontal ligament cells in vitro.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION (가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구)

  • Shin, Dong-Hoon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF

Irradiation enduced In-plane magnetization in Fe/MgO/Fe/Co multilayers

  • Singh, Jitendra Pal;Lim, Weon Cheol;Song, Jonghan;Kim, Jaeyeoul;Asokan, K.;Chae, Keun Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.188.1-188.1
    • /
    • 2015
  • For present investigation Fe/MgO/Fe/Co multilayer stack is grown on Si substrate using e-beam evaporation in ultrahigh vacuum. This stack is irradiated perpendicularly by 120 MeV $Ag^{8+}$ at different fluences ranging from $1{\times}10^{11}$ to $1{\times}10^{13}ions/cm^2$ in high vacuum using 15UD Pelletron Accelerator at Inter University Accelerator Centre, New Delhi. Magnetic measurements carried out on pre and post irradiated stacks show significant changes in the shape of perpendicular hysteresis which is relevant with previous observation of re-orientation of magnetic moment along the direction of ion trajectory. However increase in plane squareness may be due to the modification of interface structure of stacks. X-ray reflectivity measurements show onset of interface roughness and interface mixing. X-ray diffraction measurements carried out using synchrotron radiation shows amorphous nature of MgO and Co layer in the stack. Peak corresponding body centered Fe [JCPDS-06-0696] is observed in X-ray diffraction pattern of pre and post irradiated stacks. Peak broadening shows granular nature of Fe layer. Estimated crystallite size is $22{\pm}1nm$ for pre-irradiated stack. Crystallite size first increases with irradiation then decreases. Structural quality of these stacks was further studied using transmission electron microscopic measurements. Thickness from these measurements are 54, 36, 23, 58 and 3 nm respectively for MgO, Fe, MgO, Fe+Co and Au layers in the stack. These measurements envisage poor crystallinity of different layers. Interfaces are not clear which indicate mixing at interface. With increase fluence mixing and diffusion was increased in the stack. X-ray absorption spectroscopic measurements carried out on these stacks show changes of Fe valence state after irradiation along with change of O(2p)-metal (3d) hybridized state. Valence state change predicts oxide formation at interface which causes enhanced in-plane magnetization.

  • PDF

Cellular responses and proteomic analysis of hemolytic Bacillus cereus MH-2 exposed to epigallocatechin gallate (EGCG) (Epigallocatechin Gallate (EGCG)에 노출된 용혈성 Bacillus cereus MH-2의 세포 반응 및 프로테옴 분석)

  • Kim, Dong-Min;Park, Sang-Kook;Oh, Kye-Heon
    • Korean Journal of Microbiology
    • /
    • v.52 no.3
    • /
    • pp.260-268
    • /
    • 2016
  • The aim of this work was to investigate the cellular responses and proteomic analysis of Bacillus cereus MH-2 exposed to EGCG. Strain MH-2 was isolated from commercial Ssamjang and has the hemolytic activity. Survival of the MH-2 strain with time in the presence of different concentrations of EGCG under sublethal conditions was monitored. The amount of alginate from MH-2 strain decreased depending on the increasing concentrations of EGCG and increased depending on the exposure time at any particular EGCG concentration. Analysis of SDS-PAGE and Western blot using anti-DnaK and anti-GroEL revealed that two stress shock proteins, 70 kDa DnaK and 60 kDa GroEL were found to decrease in proportion to the EGCG concentration in exponentially growing cultures. Scanning electron microscopic analysis demonstrated the presence of protrusions and fused rod forms on the cells treated with EGCG. 2-DE of soluble protein fractions from MH-2 cultures showed 20 protein spots changed by EGCG exposure. These proteins involved in enterotoxins (hemolysin BL lytic component L1 and hemolysin BL-binding protein), chaperons (DnaK and GroEL), cell defense (peptidase M4 family proteins), and various biosynthesis and energy metabolism were identified by peptide mass fingerprinting using MALDI-TOF. These results provide clues for understanding the mechanism of EGCG-induced stress and cytotoxicity on B. cereus MH-2.

Expansion Behavior of Aggregate of Korea due to Alkali-Silica Reaction by ASTM C 1260 Method (ASTM C 1260 실험에 의한 국내 골재의 알칼리-실리카 반응 팽창 특성)

  • Yun, Kyong-Ku;Hong, Seung-Ho;Han, Seung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.431-437
    • /
    • 2008
  • The concrete pavement at Seohae Expressway in Korea has suffered from serious distress, only after four to seven years of construction. The deterioration of ASR has seldom been reported per se in Korea, because the aggregate used for the cement concrete has been considered safe against alkali-silica reaction so far. The purpose of this study is to examine the expansion behavior of aggregates of Korea due to alkali-silica reaction by ASTM C 1260 standard method of the accelerated mortar bar test (AMBT), stereo microscopic analysis, scanning electronic microscope (SEM) analysis, and electron dispersive X-ray spectrometer (EDX) analysis. The results are presented as it follows. The accelerated mortar bar test (AMBT) showed that mica granite and felsite of igneous rocks, aroke, red sandstone and shale of sedimentary rocks, slate of metamorphic rock, and dendrite and quartz of mineral rock showed more expansion than 0.1% at 14 days. But, some sedimentary rocks and metamorphic rocks expanded more than 0.1% at 28 days even though they were less than 0.1% at 14 days. The mortar bars, which showed more than occurred 0.1% expansion, resulted in cracking on surface. SEM and EDX analysis confirmed that the white gel was a typical reaction product of ASR. The ASR gel in Korea mainly consisted of Silicate (Si) and Potassium (K) from the cement. The crack in the concrete pavement was caused by ASR. It seems that Korea is no longer safe zone against alkali-silica reaction.

Characterization and Identification of an Agar-Degrading Motile Bacteria Strain (Agar를 분해하는 swarming 박테리아 균주의 특성과 동정)

  • Kang, Sung-Wan;Yoo, Ah-Young;Yu, Jong-Earn;Kang, Ho-Young
    • Journal of Life Science
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2012
  • A bacterial strain, CK214, exhibiting high motility on an LB agar (1.5%, w/v) surface was isolated from the environment. The formation of unusual agar shrinking around colonies on agar plates was observed. The strain grew on minimal media containing pure agar as a sole carbon source. The cell-free culture supernatant of CK214 generated a reduced form of sugar in the in vitro reaction with the use of pure agar as a substrate, suggesting the secretion of an agar-degrading enzyme. The CK214 strain showed swarming motility on the solid media containing a wide range of concentrations of agar (0.5, 1.0, 1.5, 2.0% w/v). Various tests, including Gram staining, API analysis, and phylogenetic analysis based on 16S rDNA sequences identified that the CK214 strain was a G(+) rod-shaped bacterium grouped in genus Paenibacillus. Electron microscopic analysis demonstrated that the P. CK214 strain is peritrichously flagellated. Through transposon random mutagenesis, several agar-degrading activity defective mutants (ADMs) were generated. These mutants will be used in the future experimentation for the study of the correlation between agar-degrading activity and motility.

AN EXPERIMENTAL STUDY ON THE ALTERATIONS OF ION-BEAM-ENHANCED ADHESIONS ON A VARIETY OF CERAMIC-METAL INTERFACES (이온선 혼합법이 도재-금속 계면 변화에 미치는 영향에 관한 실험적 연구)

  • Chung Keug-Mo;Park Nam-Soo;Woo Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.135-154
    • /
    • 1992
  • This study was performed to analyze bond strength, the alterations of the interfaces between metal films which are populary used and considered to contribute to the chemical reaction with porcelain, according to constant ion- beam- mixing, and the relation between interfacial chemical reactions and bond strength in metal/porcelain specimens. For this study, three seperate metals : selected-gold, indium and tin were chosen ; each to be bonded to a seperate body porcelain. Bonding occurs when the metal is deposited to the body porcelain using a vacuum evaporator. The vacuum evaporator used $10^{-5}\sim10^{-6}$ Torr vacuum states for the evaporation of various metals (Au, Sn, In). Ion-beam-mixing of the porcelain/metal interfaces caused reactions when the Ar+ was implanted into thin films using a 80 KeV accelerator. These ion-beam-mixed specimens were then compared with an unmixed control group. An analysis of bond strength and ionic changes between the the metal and porcelain was performed by electron spectroscopy of chemical analysis (ESCA) and scratch test. The finding led to the following conclusions : 1. Light microscopic views of the scratch test : The ion-beam-mixed Au/porcelain specimen showed narrower scratched streams than the unmixed specimen. However, the Sn/porcelain, In/porcelain specimens showed no differences in the two conditions. 2. Acoustic emissions in scratch tests : The ion-mixed Au/porcelain, In/porcelain specimens showed signals closer to the metal/porcelain interfaces than unmixed specimens. Conversely, the ion-mixed Sn/porcelain specimen showed more critical signals in superficial portions than unmixed specimens. 3. After ion- beam-mixing, the Au/porcelain specimen showed apparently increased bond strength, and the In/porcelain specimen showed very slightly increased bond strength. However, the Sn/porcelain specimen showed no differences between ion mixed specimen and the unmixed one. 4. ESCA analysis : The ion-beam-mixed Au/porcelain specimen showed a higher peak separated value (4.3eV) than that of the unmixed specimen(3.65eV), the ion-beam-mixed In/porcelain specimen showed a higher peak separated value (9.43eV) than that of the unmixed specimen(7.6eV) and the ion-beam-mixed Sn/porcelain specimen showed a higher peak separated value (8.79eV) than that of the unmixed specimen(8.5eV). 5. Interfacial changes were observed in the ion-mixed Au/porcelain, In/porcelain and Sn/porcelain specimens. Especially, significant interfacial changes were measured in the ion- mixed Sn/porcelain specimen. Tin dioxide(SnO2) and a combination of pure tin and tin dioxide (Sn+SnO2) were produced. 6. In the Au/porcelain specimen, the interfacial chemical reaction showed increased bond strength between gold and porcelain substrate. But, in the In/porcelain, Sn/porcelain specimens, interfacial chemical reactions did not affected the bond strength between metal and porcelain substrate. Especially, bonding strength on the ion mixed Sn/porcelain specimen showed the least amount of difference.

  • PDF

Clinical Observations on 12 Children with Alport Syndrome (Alport 증후군 환아 12명의 임상적 고찰)

  • Bae Young-Min;Kim Seoung-Do;Kang Hyeon-Ho;Cho Byoung-Soo
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.48-56
    • /
    • 2000
  • Purpose: Alport SD., the most common herectitary rephriris, is a renal disease with rapid progression. Deafness, ocular abnormalities and a specific EM finding may be associated in addition to a family history. We have aralyged retrospectively. Methods: We observed 12 children with Alport syndrome who were diagnosed at Dept. of pediatrics in Kyunghee Univ., College of Medicine, from Apr. 1991 until Jun. 1999. We used four criteria for diagnosis: renal disease, family history, deafness or eye abnormalities, and a specific finding in electron microscopy Results: 2 of 12 patients had all features of the four diagnostic criteria. We could not trace an exact family history in 3 patients, and 6 patients did not exhibit deafness or eye abnormality. One could not have renal biopsy because offer chronic renal failure. Other three criteria were observed in her. The ratio of male to female observed was 1:2 respectively and the mean age of initial renal symptom was 5.6 years. 9 of 12 patients had a family history of renal disease. In the audiogram and ocular examination for 11 of 12 cases, sensorineural hearing loss was observed in 6 and ocular abnormality in 2 cases. In electron microscopic finding, irregular thickness of the capillary basement membranes with lamination of lamina densa and foot process obliteration was noted in 9 of 11 and thin basement membrane with splitting and foot process obliteration was noted in the other 2. The mean period of follow-up was 3 6/12 years. And one patient developed the chronic renal failure until now and had kidney transplantation. Conclusion: For the diagnosis of Alport syndrome, the following four diagnostic criteria are very important : renal disease, family history, deafness or eye abnormalities, and a specific finding on electron microscopy. We expect that more patients can be detected through the analysis of these characteristics.

  • PDF