Characterization of Silica in Hongcheon (홍천산(洪川産) Silica의 특성연구(特性硏究))

  • Shin, Kun-Chul
    • Journal of Industrial Technology
    • /
    • v.4
    • /
    • pp.55-60
    • /
    • 1984
  • Silicastone of Hongcheon in Kangweon province was characterized by means of chemical analysis, scanning electron microscope, polarization microscope and x-ray diffractometer. The results showed that the purity of $SiO_2$ is over 97.64 in Wt-%. It also contains 0.046-0.417 Wt-% $Fe_2O_3$ and some others as impurity. The impuity exist as a isolated mineral type of hematite, sericite, apatite etc.

  • PDF

Frictional and Wear Characteristics of Non-Asbestos Materials at Elevated Temperature (고온에서 비석면 마찰재의 마찰$cdot$마모특성)

  • 안병길;최웅수;권오관
    • Tribology and Lubricants
    • /
    • v.7 no.2
    • /
    • pp.61-66
    • /
    • 1991
  • The frictional and wear characteristics of non-asbestos friction materials made of four different fibers (carbon, aramid, ceramic and glass) have been investigated at elevated temperature using High Frequency Friction Tester. On the basis of the experimental results, friction and wear phenomena of four different non-asbestos fibers were caused by lattice layer film of carbon, polymeric transfer film of aramid, abrasion of ceramic and adhesion of glass fiber under each contact junction. The surface analysis of the worn specimens and counter parts after tests were observed using Scanning Electron Microscope and Optical Microscope.

Property of Nickel Silicides on ICP-CVD Amorphous Silicon with Silicidation Temperature (ICP-CVD 비정질 실리콘에 형성된 처리온도에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Jong-Ryul;Choi, Young-Youn;Park, Jong-Sung;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.303-310
    • /
    • 2008
  • We fabricated hydrogenated amorphous silicon(a-Si:H) 140 nm thick film on a $180\;nm-SiO_2/Si$ substrate with an inductively-coupled plasma chemical vapor deposition(ICP-CVD) equipment at $250^{\circ}C$. Moreover, 30 nm-Ni film was deposited with a thermal-evaporator sequently. Then the film stack was annealed to induce silicides by a rapid thermal annealer(RTA) at $200{\sim}500^{\circ}C$ in every $50^{\circ}C$ for 30 minuets. We employed a four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscope(FE-SEM), transmission electron microscope(TEM), and scanning probe microscope(SPM) in order to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure evolution, and surface roughness, respectively. We confirmed that nano-thick high resistive $Ni_3Si$, mid-resistive $Ni_2Si$, and low resistive NiSi phases were stable at the temperature of <300, $350{\sim}450^{\circ}C$, and >$450^{\circ}C$, respectively. Through SPM analysis, we confirmed the surface roughness of nickel silicide was below 12 nm, which implied that it was superior over employing the glass and polymer substrates.

Characterization of a Sapstaining Fungus, Ophiostoma floccosum, Isolated from the Sapwood of Pinus thunbergii in Korea

  • Yun, Yeo-Hong;Hyun, Min-Woo;Suh, Dong-Yeon;Kim, Seong-Hwan
    • Mycobiology
    • /
    • v.37 no.1
    • /
    • pp.5-9
    • /
    • 2009
  • An Ophiostoma fungus was isolated from a stump of Pinus thunbergii in a forest on the West coast of Korea. Microscopic analysis using a light microscope, a stereo microscope, and a scanning electron microscope revealed that it had morphological features of Pesotum and Sporothix synanarmorphs. Based on the $\beta$-tubulin gene sequence analysis, the fungus was identified as the anamorph of Ophiostoma floccosum. Mycological properties of the species including its growth properties on different culture media were described.

Metallurgical Failure Analysis on a Suspension Clamp in 154kV Electric Power Transmission Tower

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.237-240
    • /
    • 2021
  • Failure of a suspension clamp made of hot dip galvanized cast iron in 154kV transmission tower was investigated. Metallurgical analysis of a crack of the clamp was performed using a digital microscope, an optical microscope, and a scanning electron microscope. It was revealed that the crack surface was covered by continuous zinc layer. Distinctive casting skin was found underneath both the outer surface and crack surface. The result showed that pre-existing crack had been formed in the fabrication, and liquid metal embrittlement during hot dip galvanization may assist crack propagation.

Statistical Analysis of Characteristics of Scanning Electron Microscope (주사전자현미경 특성의 통계적 해석)

  • Kim, T.S.;Kim, W.;Kim, D.H.;Kim, B.
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.4
    • /
    • pp.185-189
    • /
    • 2007
  • A scanning electron microscope (SEM) is a complex system, consisting of many sophisticated components. For a systematic characterization, a $2^4$ full factorial experiment was conducted. The SEM components examined include condenser lens 1 and 2 (denoted as A and B, respectively), and Objective lens (coarse and fine-denoted as C and D respectively). A statistical analysis was conduced to investigate factor effects and variations In response surfaces. Among four factors, main effect analysis revealed that A and D were Identified as the dominant factor. Moreover, B showed conflicting effect against C. The $R^2$ of statistical regression model constructed was about 69.6%. The model generated 3D response surface plots facilitated understanding of complex tactor effects.

Characteristics of Contact resistivity on RTP annealing temperature and time after Plasma ion implant (플라즈마 이온주입 후 RTP 열처리 온도와 시간에 따른 접촉저항 특성)

  • Choi, Jang-Hun;Do, Seung-Woo;Lee, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.5-6
    • /
    • 2009
  • In this paper, plasma ion implant is performed with $PH_3$ gas diluted by helium gas on P-type Si wafer (100). Spike Rapid Thermal Processing(RTP) annealing performed for 30~60 sec from $800\;^{\circ}C$ to $1000\;^{\circ}C$ in $N_2+O_2$ ambient. Crystalline defect is analyzed by Transmission Electron Microscope(TEM) and Double crystal X-ray Diffraction(DXRD). Contact resistivity($\rho c$), contact resistance(Rc) and sheet resistance(Rs) are analyzed by measuring Transfer Length Method(TLM) using 4155C analysis. As annealing temperature increase, Rs decrease and ${\rho}c$ and Rc increase at temperature higher than $850\;^{\circ}C$. We achieve low Rs, ${\rho}c$ and Rc with Plasma ion implant and spike RTP.

  • PDF

Fabrication and Linear & Nonlinear Optical Characterization of Photonic Crystals (포토닉 밴드갭 광결정의 제작과 선형 및 비선형 광학 특성 연구)

  • Ha Na Yeong;U Yeon Gyeong;Hwang Ji-Su;Jang Hye-Jeong;Park Byeong-Ju;U Jeong-Won
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.162-163
    • /
    • 2002
  • 1-D photonic band-gap structure is identified in a cholesteric liquid crystal system. The optical transmission spectrum is measured and compared with the theoretical analysis. Nonlinear transmission is measured near the band edge. Also 3-D photonic band-gap structures are fabricated from dielectric colloidal polystyrene beads through a centrifuge method. The fabricated photonic crystals exhibit opalescent colors under white light and show a clear diffraction peak dependent on the incident angle of the light beam. Also the scanning electron microscope image was taken to verify the face-centered cubic crystal structure. Bragg's law and Snell's law are employed to describe the position of angle resolved diffraction peaks. It was shown that the optically deduced effective refractive index and lattice constants were in good agreement with the crystal structure identified by scanning electron microscope.

  • PDF

Biological Applications of Helium Ion Microscopy

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • v.43 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • The helium ion microscope (HIM) has recently emerged as a novel tool for imaging and analysis. Based on a bright ion source and small probe, the HIM offers advantages over the conventional field emission scanning electron microscope. The key features of the HIM include (1) high resolution (ca. 0.25 nm), (2) great surface sensitivity, (3) great contrast, (4) large depth-of-field, (5) efficient charge control, (6) reduced specimen damage, and (7) nanomachining capability. Due to the charge neutralization by flood electron beam, there is no need for conductive metal coating for the observation of insulating biological specimens by HIM. There is growing evidence that the HIM has substantial potential for high-resolution imaging of uncoated insulating biological specimens at the nanoscale.

A Study on the Alkali-Aggregate Reaction of Quartz and Feldspars in Concrete Structure (콘크리트 구조물에서 석영, 장석의 알카리-골재반응의 연구)

  • 하성호;김무한;유신애;정지곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.164-169
    • /
    • 1995
  • Cracks in the concrete structure are known to develope by various mechani는, including an alkali-aggregate reaction. The alkali-silicate reaction between aggregates and cement is studied using polarized microscope, electron probe microanalyser and electron microscope. Metamorphosed, biaxial quartz and feldspars grains appear to have reacted readily with alkali from cement. For a given mineral, fine-grained minerals tend to react readily over the coarse-grained ones. A chemical analysis shows that the elements K, Na, Ca, and Si migrated, in most cases, fro the portion of h호 concentration to the low, Some clay minerals, including smectite and illite are newly formed as one of the reaction products. The continual expansion and shrinkage of the expandible clay minerals, probably due to repeated absorption and loss of water within the structure, plays an important role in the development of cracks within the concrete structure.

  • PDF