• Title/Summary/Keyword: electron microscope

Search Result 4,378, Processing Time 0.032 seconds

Possibility of cementation of soft soil using Bacteria (Bacteria를 이용한 연약한 흙의 고결화 가능성)

  • Kim, Dae-Hyeon;Kim, Ho-Chul;Park, Kyoung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.379-391
    • /
    • 2010
  • In order to understand the mechanism of cementation of soft soils treated with bacteria, three types of specimens(untreated, normal bacteria concentration treated, and high bacteria concentration treated) were made. Scanning Electron Microscope(SEM), EDX and X-ray diffraction(XRD) analyses were performed on the soft silt and loose sand specimens. Compared with the untreated specimen, a clearer cementation between particles was observed in the high bacteria concentration treated specimen. Based on the scanning electron microscope(SEM) EDX analyses, more calcium carbonate was observed in the specimen treated with high bacteria concentration than other specimens. On the basis of the preliminary results, it appears that microbial cementation can occur in the soft soil. Further study on the cementation of soils using bacteria is necessary to validate this result.

  • PDF

Variation of Camera Constant and Image Rotation in HU-125C Electron Microscope (HU-125C 전자현미경에 있어서 카메라 상수의 변화 및 상의 회전에 대한 조사)

  • Choi, Ju;Ye, Gil-Chon
    • Applied Microscopy
    • /
    • v.4 no.1
    • /
    • pp.1-4
    • /
    • 1974
  • Variations of camera constant due to the change of the lens current were examined for Hitachi HU-125C electron microscope. It was shown that the variation in specimen height had a marked effect on the change of camera constant. Also the rotation of the image from the diffraction pattern was determined by using a test crystal. Suggestions were given for improving practical operation of electron microscope in the work of thin foils.

  • PDF

Analysis of Damaged Instance and Forming Fault for Disc Part in Automotive Steel Wheel (자동차용 스틸휠 디스크부품의 성형불량 및 파손사례분석)

  • Lee, Sung-Hee;Kim, M.Y.;Kim, T.G.;Yun, H.Y.;Kang, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.234-238
    • /
    • 2006
  • In this research, an analysis of damaged instance and forming fault for disc part in automotive steel wheel was performed. Rolled steel material, which had been used in the manufacturing of the damaged disc part, was prepared for tensile test, quantitative analysis of chemical component and acquirement of scanning electron microscope images. Although the results of mechanical properties and chemical component ratio for the material satisfied the suggested specification, some material inherent problem was found in the scanning electron microscope images. Finally, in an analysis of chemical component for the damaged disc part used in road condition, mismatching of chemical component ratio between the suggested specification and test result was found.

  • PDF

Plasma Diagnosis by Using Scanning Electron Microscope and Neural Network (신경망과 주사전자현미경을 이용한 플라즈마 진단)

  • Bae, Jung-Gi;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.96-98
    • /
    • 2006
  • A new ex-situ model to diagnose a plasma processing equipment was presented. The model was constructed by combining wavelet, scanning electron microscope, ex-situ measurement of etching profile, and neural network. The diagnosis technique was applied to a tungsten etching process, conducted in a $SF_6$ helicon plasma. The wavelet was used to characterize detailed variations of plasma-etched surface. The diagnosis model was constructed with the vertical wavelet component. For comparison, a conventional model was built by using the estimated profile data. Compared to the conventional model, the wavelet-based model, demonstrated a much improved diagnosis.

  • PDF

DIMENSIONAL STABILITY AND SURFACE MORPHOLOGY OF VARIOUS DENTURE RESINS (의치상 레진의 중합 방법에 따른 크기의 안정성 및 표면 형태에 관한 연구)

  • Chae Sook-Young;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.401-410
    • /
    • 1992
  • The purpose of this study was to investigate the dimensional changes and surface morphology of dentures processed by various polymerization conditions. The measurements were done by taking radiograph and using vernier calipers and each specimen was observed on scanning electron microscope. Results obtained were as follows. 1. The difference of dimensional stability was not recognized between various polymerization conditions(heat-cured resin, pour-type resin, microwave-cured resin, and injection molding resin). 2. There were expansion and shrinkage in the occlusal dimension, shrinkage in the frontal dimension, and expansion in the lateral dimension. 3. Scanning electron microscope pictures of heat-cured resin showed dense and regular surface morphology. 4. Microwave-cured resin surface appeared more regular and smooth than pour-type resin but less dense and more irregular than heat-cured resin. 5. Scanning electron microscope pictures of pour-type resin with the lowest dimensional change showed the most irregular surface morphology.

  • PDF

Effect of Sc Addition on the Microstructure Modification of Al-6Si-2Cu Alloy (Sc 첨가에 따른 Al-6Si-2Cu 합금의 미세조직 개량화)

  • An, Seongbin;Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.3
    • /
    • pp.150-158
    • /
    • 2022
  • The effects of scandium addition on the Al-6Si-2Cu Alloy were investigated. The Al-6Si-2Cu-Sc alloy was prepared by gravity die casting process. In this study, scandium was added at 0.2 wt%, 0.4 wt%, 0.8 wt%, and 1.0 wt%. The microstructure of Al-6Si-2Cu-Sc alloy was investigated using Optical Microscope, Field Emission Scanning Electron Microscope, Electron Back Scatter Diffraction, and Transmission Electron microscope. The microstructure of Al-6Si-2Cu alloy with scandium added changed from dendrite structure to equiaxed crystal structure in specimens of 0.4 wt% Sc or more, and coarse needle-shape eutectic Si and β-Al5FeSi phases were segmented and refined. The nanosized Al3Sc intermetallic compound was observed to be uniformly distributed in the modified Al matrix.

Stem cell behaviors on periodic arrays of nanopillars analyzed by high-resolution scanning electron microscope images

  • Jihun Kang;Eun-Hye Kang;Young-Shik Yun;Seungmuk Ji;In-Sik Yun;Jong-Souk Yeo
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.26.1-26.3
    • /
    • 2020
  • The biocompatible polyurethane acrylate (PUA) nanopillars were fabricated by soft lithography using three different sizes of nanobeads (350, 500, and 1000 nm), and the human adipose-derived stem cells (hASCs) were cultured on the nanopillars. The hASCs and their various behaviors, such as cytoplasmic projections, migration, and morphology, were observed by high resolution images using a scanning electron microscope (SEM). With the accurate analysis by SEM for the controlled sizes of nanopillars, the deflections are observed at pillars fabricated with 350- and 500- nm nanobeads. These high-resolution images could offer crucial information to elucidate the complicated correlations between nanopillars and the cells, such as morphology and cytoplasmic projections.

HISTOLOGIC STUDY OF VARIOUS DENTAL IMPLANT-TISSUE INTERFACE (수종의 치근형 골내매식체와 조직간의 반응에 관한 조직학적 연구)

  • Lee, Ho-Young;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.7-23
    • /
    • 1990
  • The success or failure of endosseous dental implants is related to the cellular activity at the implant surface. Success seems to be associated with the enclosure of the implant in a non-inflammed connective tissue or the formation of a direct bone implant interface. The purpose of this study was to examine the tissue reactions to the various implants at the submergible state in dog mandible. The $Br\"{a}nemark$, Core-Vent, Intergral, Bone spiral were selected for evaluation and also the Kimplant, Nephrite were used for the experimental study. After 4 months the animals were sacrificed. The interface zone between bone and implant was investigated using x-rays, light microscope, scanning electron microscope, transmission electron microscope. The following results were obtained from this study. 1. $Br\"{a}nemark$, Core-Vent, Kimplant, Integral showed no mobility and bone growth over the healing screws of the implants. Histologically most of the implant surface were covered by remodelled lamellar bone, and partly by a cellular layer or the thin fibrous tissue layer. 2. The Bone spiral showed no mobility and partially radiolucent line around the implant. The upper part of the implant was surrounded by a thin fibrous connective tissue and the middle, apical part of it were contacted with bone directly. 3. The Nephrite implant showed severe mobility and a radiolucent line around the implant. Histologically it showed mild inflammation and was surrounded by a fibrous connective tissue. 4. Scanning electron microscope showed that there was no amorphous ground substance in the Nephrite implant but the formation of ground substance over the collagen filaments in other implants. 5. Transmission electron microscope showed that collagen filaments were approached irregularly to the surface of all implants and in the $Br\"{a}nemark$, Core-Vent, Kimplant, Integral there was amorphous layer between the implant and the collagen filaments. It seemed to be ground substances.

  • PDF

Development of Intelligent Remote Beam Control Function in E-Beam Manufacturing System (전자빔 가공기의 지능형 원격 빔 조절 기능의 개발)

  • Lim Sun-Jong;Lyou Joon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.24-29
    • /
    • 2006
  • The use electron-beam(E-beam) manufacturing system provides a means to alleviate optic exposure equipment's problems. We are developing an E-beam manufacturing system with scanning electron microscope(SEM) function. The E-beam manufacturing system consist of high voltage generator, beam blanker, condenser lenses, object lenses, stigmator and stage. The development of E-beam manufacturing system is used on the method of remaking SEM's structure. The functions of SEM are developed. It is important for the test of E-beam performance. In E-beam manufacturing system and SEM, beam focus is important function. In this paper, we propose intelligent remote control function for beam focus in E-beam manufacturing system. The function extends the user's function and gives convenience.