• Title/Summary/Keyword: electron field

Search Result 2,626, Processing Time 0.03 seconds

Numerical Calculation Study on the Generalized Electron Emission Phenomenon

  • Kim, Hee-Tae;Yu, Soon-Jae
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.158-163
    • /
    • 2009
  • There are two kinds of well-known electron emissions from metal: field and thermionic emission. For thermionic emission, electrons come out of a metal due to the thermal energy, whereas for field emission, electrons tunnel out of a metal through the strong electric field. In this study, the most general electron emission caused by the temperature and electric field with a free electron gas model was considered. The total current density of electron emission comes from the field emission effect, where the electron energy is lower than vacuum, and from the thermionic-emission effect, where the electron energy is higher than vacuum. The total current density of electron emission is shown as a function of the temperature for a constant electric field, and as a function of the electric field for a constant temperature.

Electron Emission from $Pb(Zr_xTi_{1-x})O_3$ Ferroelectrics by Pulsed Electric Field (펄스 전기장에 의한 $Pb(Zr_xTi_{1-x})O_3$ 강유전체의 전자 방출)

  • 김용태;윤기현;김태희;박경봉;곽상희
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.1
    • /
    • pp.6-11
    • /
    • 2000
  • Electron emission from the Pb(ZrxTi1-x)O3 ferroelectrics by pulsed electric field has been investigated as a function of Zr/Ti ratios such as 35/65, 50/50 and 65/35 below 250kV/cm. Electrons were emitted regardless of the applied field polarity to the rear electrode. When the negative field was applied to the rear electrode, the electron emission charge was more stable. It was proved that the electrons were emitted at the edge of the upper electrode. The emission charge increased in order of 65/35>50/50>35/65. The electron emission characteristics were dependent on the ferroelectric properties such as polarization and coercive field. The emission charge and emission threshold field were affected by the polarization change and the coercive field, respectively. This result explains that the electron emission is a field emission with polarization induced surface potential by a modified Fowler-Nordheim plot of emission charge.

  • PDF

Electron Emission Theory for LCD Backlight

  • Kim, Hee-Tae;Lee, Dong-Chin;Nam, Seok-Hyun;Jang, Tae-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1602-1605
    • /
    • 2008
  • We considered most general electron emission caused by temperature as well as electric field with a free electron gas model. The total electron emission current density comes from field emission effect where electron energy is lower than vacuum and from thermionic emission effect where electron energy is higher than vacuum. The total electron emission current density is shown as a function of temperature for constant electric field, and as a function of electric field for constant temperature.

  • PDF

Electron Beam Coherency Determined from Interferograms of Carbon Nanotubes

  • Cho, B.;Oshima, C.
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.892-898
    • /
    • 2013
  • A field emission projection microscope was constructed to investigate the atomic and chemical-bonding structure of molecules using electron in-line holography. Fringes of carbon nanotube images were found to be interferograms equivalent to those created by the electron biprism in conventional electron microscopy. By exploiting carbon nanotubes as the filament of the electron biprism, we measured the transverse coherence length of the electron beam from tungsten field emitters. The measurements revealed that a partially coherent electron-beam was emitted from a finite area.

A Consideration on the Characteristics of Electron Beam Dose Distributions for Clinical Applications (임상적용을 위한 전자선의 선량분포 특성에 대한 고찰)

  • Cha, Dong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2010
  • High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.

  • PDF

Electron Holography of Advanced Nanomaterials

  • Shindo, D.;Park, H.S.;Kim, J.J.;Oikawa, T.;Tomita, T.
    • Applied Microscopy
    • /
    • v.36 no.spc1
    • /
    • pp.63-69
    • /
    • 2006
  • By utilizing a field emission gun and a biprism installed on a transmission electron microscope (TEM), electron holography is extensively carried out to visualize the electric and magnetic fields of nanomaterials. In the electric field analysis, the distribution of electric potential in a sharp tip made of W coated with $ZrO_2$ is visualized by applying the voltage to the tip. Denser contour lines due to the electric potential are observed with an increase in the bias voltage. In the magnetic field analysis by producing the strong magnetic field with a sharp magnetic needle made of a permanent magnet, the in situ experiment is carried out to investigate the magnetization of hard magnetic materials. The results of these experiments clearly demonstrate that electron holography is a promising advanced transmission electron microscopy technique to characterize the electric and magnetic properties of nanomaterials.

Simulation Study of Corona Discharge According to Flue Gas Conditions (배기가스 조건에 따른 코로나 방전 현상 시뮬레이션)

  • 정재우;조무현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.223-231
    • /
    • 2001
  • In order to provide some insights into the influence of electric field, gas composition, and gas temperature on electron energy distribution and electron transport characteristics, the Boltzmann equation was solved by using cross section data for electron collisions, Critical electric fields for the corona development in dry air and flue gas are 150 and 80 Td, respectively. It was seen that the decrease of critical electric field in flue gas is mainly caused by the $H_2O$ addition through the comparison of ionization and attachment coefficients of gas components. Increase of $O_2$, $H_2O$, and $CO_2$ contents in gas affected discharge characteristics according to their reciprocal characteristics between lowering the ionization threshold and increasing the electro-negativity. As electric field increases, electrons with higher energies in the electron energy distribution also increase. The mean and characteristic electron energies also linearly increase with electric field. The variation of flue gas temperature did rarely affect on the electron energy distribution function and electron transport characteristics, because the gas temperature is several hundreds or thousands times lower than the electron temperature.

  • PDF

Hardware Design for the Control Signal Generation of Electron Optic by Focal Length (Focal length에 의한 전자 렌즈의 제어 신호 생성을 위한 하드웨어 설계)

  • Lim, Sun-Jong;Lee, Chan-Hong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.96-100
    • /
    • 2007
  • Condenser lens and objective lens are used to demagnify the image of the crossover to the final spot size. In lens, electrons are focused by magnetic fields. This fields is fringing field. It is important in electron focusing. Electron focusing occurs the radial component field and axial component field. Radial component produces rotational force and axial component produces radial force. Radial force causes the electron's trajectory to curve toward the optic axis and corss it. Focal length decreases as the current of lens increases. In this paper, we use the focal length for desiging the hardware of lens current control and present the results.

Electron sources for electron microsocpes (전자현미경의 전자원)

  • Cho, Boklae
    • Vacuum Magazine
    • /
    • v.2 no.2
    • /
    • pp.24-28
    • /
    • 2015
  • The brightness of an electron source, along with the aberrations of an objective lens, determines the image resolution and beam current on samples, which are two important parameters for evaluating the performance of an electron microscope. Here we introduce thermal electron source, Schottky emitter and cold field electron emitter. Thermal electron source is the cheapest and stable electron source but it has the lowest brightness. Schottky emitter is 10000 times brighter than tungsten thermal electron source, but requires ultrahigh vacuum operating condition. Cold field electron emitter is 10 times brighter than Schottky emitters, but it is rather unstable and its operation requires most stringent vacuum condition, hindering its widespread use.

Variation of Effective SSD According to Electron Energies and Irradiated Field Sizes (전자선 에너지 및 조사야에 따른 유효선원 피부 간 거리 변화)

  • Yang, Chil-Yong;Yum, Ha-Yong;Jung, Tae-Sik
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.157-163
    • /
    • 1987
  • It is known that fixed source to skin distance (SSD) cannot be used when the treatment field is sloped or larger than the size of second collimator in electron beam irradiation and inverse square law using effective ssd should be adopted. Effective SSDs were measured in different field sizes in each 6, 9, 12, 15 and 18MeV electron energy by suing NELAC 1018D linear accelerator of Kosin Medical Center. We found important parmeters of effective SSD. 1. Minimum effective SSD was 58.8cm in small field size of $6\pm6cm$ and maximum effective SSD was 94.9cm in large field size of $25\pm25cm$, with 6MeV energy. It's difference was 36.1cm. The dose rate at measuring point was quite different even with a small difference of SSD in small field $(6\times6cm)$ and low energy (6 MeV). 2. Effective SSD increased with field size in same electron energy. 3. Effective SSDs gradually increased with the electron energies and reached maximum at 12 or 15 MeV electron energy and decreased again at 18MeV electron energy in each identical field size. And so the effective SSD should be measured in each energy and field size for practical radiotherapy.

  • PDF