• Title/Summary/Keyword: electron beam treatment

Search Result 280, Processing Time 0.028 seconds

Physico-Chemical Characteristics of Sewage Sludge under Electron Beam Irradiation (전자선으로 처리한 하수슬러지의 특성연구)

  • Shin, Kyung-sook;Kang, Ho;Bang, Ky-youn
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1225-1232
    • /
    • 2000
  • This study was carried out to define the effect of electron beam irradiation on the physico-chemical characteristics of sewage sludges. The experimental evidence showed that both pH and alkalinity of irradiated sludge were generally increased as the dose of irradiation increased. It was found that the soluble protein concentration (SPC) and soluble chemical oxygen demand (SCOD) from the sludge right after electron beam irradiation at 3kGy(kilo-joule/kg) increased 2.2 times and 10 times respectively more than those sludges without electron beam treatment. This highly solubilized organics could be resulted in a good soluble substrate for the subsequent anaerobic digestion process. The specific resistance of filtration (SRF) tests showed that sludge dewaterability under electron beam irradiation at 6kGy was found to be 8.8 times higher than that of unirradiated sludge. The sludge dewaterability seemed to be directly related to the dosage of electron beam irradiation up to 10kGy. However, the efficiency of sludge dewaterability tended to be smaller with higher applied irradiation dose. In comparing treatments by different inorganic chemical conditioner with irradiated and unirradiated sludges, it appeared that the dewaterability with irradiated sludge was approximately 4-10 times better that that of unirradiated sludge. Even electron beam treatment itself could replace the result from the sludge conditioned with inorganic chemical coagulants.

  • PDF

Effect of Electron Beam Irradiation on the Anti-allergy Activity of β-Glucan (전자선 조사가 베타글루칸의 항알레르기 활성에 미치는 영향)

  • Park, Jong-Heum;Sung, Nak-Yun;Byun, Eui-Beak;Song, Du-Sup;Kim, Jaekyung;Song, Beom-Seok;Park, Sang-Hyun;Shin, Mi-Hae;Lee, Ju-Woon;Kim, Jae-Hun;Yoo, Young-Choon
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.267-272
    • /
    • 2012
  • This study evaluated the change in anti-allergy activity of ${\beta}-glucan$ by electron beam irradiation. ${\beta}-Glucan$ was irradiated at dose of 50 kGy and then orally pre-treated with electron beam irradiated and non irradiated ${\beta}-Glucan$ for 7 days. After pre-treatment, allergy was induced by injection of ovalbumin (OVA). Serum total immunoglobulin E (IgE) and OVA-specific IgE levels in the allergic mice was significantly increased but the mice pre-treated 50 kGy electron beam irradiated ${\beta}-glucan$ was significantly decreased the levels of total IgE and OVA-specific IgE, respectively. Moreover, cytokine production (interleukin-4) was also decreased in the 50 kGy electron beam irradiated ${\beta}-Glucan$ pre-treated mice. These results indicate that pre-treatment of 50 kGy electron beam irradiated ${\beta}-glucan$ may elevate the anti-allergy activity. Therefore, electron beam-irradiated ${\beta}-glucan$ could be used for nutraceutical foods in food industry.

Inactivation of Human Norovirus GII. 4 on Oyster Crassostrea gigas by Electron Beam Irradiation (전자선 조사에 의한 신선굴(Crassostrea gigas) 중 휴먼노로바이러스 GII. 4의 저감화)

  • Kim, Ji Yoon;Jeon, Eun Bi;Choi, Man-Seok;Park, Shin Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.1
    • /
    • pp.16-22
    • /
    • 2021
  • This study investigated the reduction in human norovirus (HNV) GII. 4 count in pacific oyster Crassostrea gigas using electron beam irradiation. Infectious HNV GII. 4 was detected using RT-qPCR (real time reverse transcription-quantitative polymerase chain reaction) with PMA (propidium monoazide)/sarkosyl. At electron beam doses 1, 5, 7, and 10 kGy, the count of HNV GII. 4 was 2.74, 2.37, 2.06, and 1.55 log copies/μL (control, 3.01 log copy/μL), respectively, confirming that as the irradiation dose increased, norovirus count reduced significantly (P<0.05). After PMA/sarkosyl treatment, the counts further reduced at the same irradiation dose, and 10 kGy showed significant differences between the non-treated and PMA/sarkosyl-treated samples (P<0.05). The Ed (decimal reduction dose of electron beam) value based on the first-order kinetic model was 7.33 kGy (R2=0.98). No significant difference was observed in the pH values of the control (6.2) and electron beam-irradiated samples at all doses (6.1). For sensory evaluation, the non-treated sample scored the highest in all categories (5.25-6.17), while the samples treated with 10 kGy showed the lowest score (4.67-5.33), although without statistical significance (P>0.05). Overall, our results suggest that 7 kGy electron beam is sufficient for the non-thermal sterilization of oysters without causing significant changes in quality.

A Study on the Properties of AZO Films Surface-annealed by RF Magnetron Sputtering and Electron Beam Radiation (전자빔 조사에 의해 표면열처리된 AZO 박막의 물성변화에 관한 연구)

  • Shin, Chang-Ho;Jeong, Cheol-Woo;Kim, Yu-Sung;Chae, Ju-Hyun;Kim, Daeil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.4
    • /
    • pp.205-209
    • /
    • 2010
  • Transparent and conductive AZO films were deposited on the glass by using radio frequency (RF) magnetron sputtering with intense electron radiation, simultaneously. After deposition, the effect of electron radiation energy on the optical and electrical properties of AZO was investigated. In XRD measurements, the films irradiated with intense electron beam show the larger grain size than that of the films prepared without electron radiation. Sheet resistance was also dependent on the electron radiation energy, while the optical transmittance in visible wavelength region was not affected seriously by electron radiation. X-.ray diffraction, UV-Vis spectrophotometer and four point probes were used to observe the crystallization, optical transmittance and sheet resistance, respectively.

Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam (Total Skin Electron Beam을 이용한 급성 골수성 백혈병 환자 치료에 대한 연구)

  • Lee, Sang-Ryul;Kang, Min-Kyu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.152-158
    • /
    • 2009
  • Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is $60^{\circ}$ around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.

  • PDF

Fire Performance of the Wood Treated with Inorganic Fire Retardants

  • Son, Dong-Won;Kang, Mee-Ran;Kim, Jong-In;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • To prepare the eco-friendly fire retardant wood, Japanese red pine (Pinus densiflora), Hemlock (Tsuga heterophylla), and Radiata pine (Pinus radiata) were treated with inorganic chemicals, such as sodium silicate, boric acid, ammonium phosphate, and ammonium borate. Different combination and concentration of those chemicals were impregnated by vacuum/pressure treatment methods. The electron-beam treatment was used to increase the chemical penetration into the wood. The fire performance of the fire retardant treated wood was investigated. The penetration of chemicals into the wood was enhanced after electron beam treatment. Ignition time of the treated wood was the most effectively retarded by sodium silicate, ammonium phosphate, and ammonium borate. The most effective chemical combination was found at 50% sodium silicate and 3% ammonium borate, which satisfied flammability criteria for a fire retardant material in the KS F ISO 5660-1 standards.

Interfacial Shear Strength and Thermal Properties of Electron Beam-Treated Henequen Fibers Reinforced Unsaturated Polyester Composites

  • Pang Yansong;Cho Donghwan;Han Seong Ok;Park Won Ho
    • Macromolecular Research
    • /
    • v.13 no.5
    • /
    • pp.453-459
    • /
    • 2005
  • Natural fiber henequen/unsaturated polyester (UPE) composites were fabricated by means of a compression molding technique using chopped henequen fibers treated at various electron beam (EB) dosages. The interfacial shear strength (IFSS), dynamic mechanical properties, and thermal expansion behavior were investigated through a single fiber microbonding test, fractographic observation, dynamic mechanical analysis, and thermomechanical analysis, respectively. The results indicated that the interfacial and dynamic mechanical properties significantly depended on the level of the EB treatment irradiated onto the henequen fiber surfaces. The effect of EB treatment on the IFSS, storage modulus and fracture surface of the henequen/UPE composites agreed with each other. The results of this study also suggested that the modification of henequen fiber surfaces at 10 kGy EB is the most effective for improving the interfacial properties of the henequen/UPE composites.

Influence of high energy electron beam treatment on the photocatalytic activity of $TiO_2$ nanoaparticles on carbon fiber

  • Sim, Chae-Won;Kim, Myeong-Ju;Seo, Hyeon-Uk;Kim, Gwang-Dae;;Kim, Dong-Un;Nam, Jong-Won;Jeong, Myeong-Geun;Lee, Byeong-Cheol;Park, Ji-Hyeon;Kim, Yeong-Dok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.441-441
    • /
    • 2011
  • $TiO_2$ nanoparticles were grown on carbon fiber by atomic later deposition (ALD) with TTIP $(Ti(OCH(CH_3)_2)_4$ and $H_2O$ precusors. After sampe surfaces were treated by electron beam (1 MeV, 5 KGy), an improvement in the photocatalytic reacitivity of $TiO_2$ nanoparticles on carbon fiber was observed. An increase in the population of hydroxyl group on $TiO_2$ particles and the oxidation of carbon fiber were found upon e-beam exposure, whereas there was no noticeable changes of their morphology. It implies that those changes in O and C 1s state of $TiO_2$ particles/carbon fiber induced by e-beam treatment could be related to the enhancement of the photocatalytic activity. In contrast, when carbon fiber fully covered with $TiO_2$ thick films was treated with high-energy electron beam under same conditions, the improvement of photocatalytic activity as well as any changes in XPS spectra (Ti 2p, O 1s and C 1s) could not be found.

  • PDF

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Evaluation of Lead Oxide Dosimeter for Quality Assurance of Electron Beam in Radiotherapy (방사선치료 전자선의 정도관리를 위한 Lead Oxide 선량계 평가)

  • Yang, Seungwoo;Han, Moojae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.79-83
    • /
    • 2021
  • In radiation therapy, electron beam is often used in the treatment of superficial lesion. Accurate measurements are required because electron beam interacts with them in the beam path and affects dose measurements. However, no research has been conducted on electron beam quality assurance. in this study, PbO-based dosimeter was fabricated as a basic study for electron beam quality assurance. Thus, the reproducibility and linearity of the energy of 6, 9, and 12 MeV were analyzed to evaluate measurement accuracy and precision. Reproducibility measurements show RSD value of 1.024%, 1.019% and 0.890%, respectively, at 6, 9, and 12 MeV. linearity measurements show 0.9999 R2 at 6, 9, and 12 MeV altogether. Both evaluations show that the PbO dosimeter has very good measurement accuracy and precision with excellent results.