• Title/Summary/Keyword: electromagnetic transducer

Search Result 72, Processing Time 0.022 seconds

A Broadband W-band Orthomode Transducer for KVN Polarization Observations

  • Chung, Moon-Hee;Je, Do-Heung;Kim, Seung-Rae
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.345-353
    • /
    • 2013
  • A W-band Orthomode Transducer (OMT) has been developed for Korean VLBI Network (KVN) polarization observation. The OMT design was based on E-plane split-block technique using septum structure. 3-dimensional electromagnetic simulation was fully employed to optimize the performance of the OMT. Measurements of the fabricated OMT show that the return losses for the vertically and horizontally polarized modes are better than -20 dB across 80 ~ 108 GHz and the insertion losses for the both modes are less than 0.47 dB. The cross-polarization level of the OMT is less than -30 dB. The bandwidth of the developed OMT is estimated as around 30%.

Development and Characterization of the Electromagnetic Acoustic Transducer for Tubes (튜브탐상용 EMAT 제작 및 특성조사)

  • Ahn, Bong-Young;Lee, Se-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 1986
  • Electromagnetic - Acoustic Transducers for the inspection of tubes were developed using permanent magnets and induction coils. The propagation velocity of ultrasonic waves in a tude wall was measured by the transducers. The position of a flaw in a tube and the relative size of flaws with different size were measured.

  • PDF

Design of An Orthomode Transducer for Use in Multi-Band Antenna Feeds (다중 대역 안테나 피드용 직교모드변환기 설계)

  • 황순미;김영민;이석곤;안병철
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.184-188
    • /
    • 2001
  • 본 논문에서는 다중대역 피드를 위한 직교모드 변환기를 설계하였다. 직교모드 변환기의 전체적인 모양은 사각 테이퍼진 형태이고, 18-20 GHz 에서 우원 편파와 좌원편파를 발생시키기 위해 테이퍼 부분에 2개의 측면포트를 두고, 직선포트는 30-45 GHz의 광대역에서 -20dB 이하의 반사계수를 가지도록 설계하였다. 직선포트에서의 반사계수 특성을 향상시키기 위해서 측면포트에 얇은 격막을 삽입하였다. 전체적인 설계에 상용소프트웨어인 HFSS$^{R}$를 사용하였다.

  • PDF

Proposal of a piezoelectric floating mass transducer for implantable middle ear hearing devices (이식형 인공중이를 위한 압전 플로팅 매스 트랜스듀서의 제안)

  • Lee, Chang-Woo;Kim, Min-Kyu;Park, Il-Yong;Song, Byung-Seop;Roh, Yong-Rae;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.322-330
    • /
    • 2005
  • A new type of transducer, piezoelectric floating mass transducer (PFMT) which has advantages of piezoelectric and electromagnetic transducer has been proposed and implemented for the implantable middle ear hearing devices. By the uneven bonding of piezoelectric material to the inner bottom of transducer case, the PFMT can vibrate back-and-forth along the longitudinal axis of the transducer even though the piezoelectric material within the cylindrical case produces only the bilateral expansion and contraction according to the applied electrical signal. To improve efficiency of the PFMT, the multi-layered piezoelectric material has been adapted. The small number of components in the PFMT enables the simple manufacturing and the easy implanting into the middle ear. In order to examine the characteristics of vibration, mechanical modeling and finite element analyses of the proposed transducer have been performed. From the result of theoretical analyses and the measured data from the experiment, it is verified that the implemented PFMT can be used in implantable middle ear hearing devices.

Design method for the 2DOF electromagnetic vibrational energy harvester

  • Park, Shi-Baek;Jang, Seon-Jun
    • Smart Structures and Systems
    • /
    • v.25 no.4
    • /
    • pp.393-399
    • /
    • 2020
  • In this paper, the design method and experimental validation for the two-degree-of-freedom (2DOF) electromagnetic energy harvester are presented. The harvester consists of the rigid body suspended by four tension springs and electromagnetic transducers. Once the two resonant frequencies and the mass properties are specified, both the constant and the positions for the springs can be determined in the closed form. The designed harvester can locate two resonant peaks close to each other and forms the extended frequency bandwidth for power harvesting. Halbach magnet array is also introduced to enhance the output power. In the experiment, two resonant frequencies are measured at 34.9 and 37.6 Hz and the frequency bandwidth improves to 5 Hz at the voltage level of 207.9 mV. The normalized peak power of 4.587 mW/G2 is obtained at the optimal load resistor of 367 Ω.

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.

Experimental Evidence and Analysis of a Mode Conversion of Guided Wave Using Magnetostrictive Strip Transducer (자기변형 스트립 탐촉자에 의한 유도초음파 모드 변환에 대한 실험적 검증 및 해석)

  • Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • An advantage of a magnetostrictive strip transducer for a long-range guided wave inspection is that the wave patterns are relatively clear and simple when compared to a conventional piezoelectric ultrasonic transducer. Therefore, if we can characterize the evolution of defect signals, it could be a promising tool for a structural health monitoring of pipes for a long period of time as well as an identification of flaws. However, when evaluating a signal during a realistic field examination, it should be careful because of some spurious signals or false indications, such as signals due to a directionality, multiple reflections, mode conversion, geometrical reflections etc. Mode converted signals from a realistic piping mockup were acquired and analysed. We found mode conversions between a torsional guided wave T(0,1) mode and a flexural F(1,3) or longitudinal L(0,2) mode generated by a magnetostrictive strip transducer. Based on the experimental observations, an interpretation of the source of the mode conversion is discussed in a viewpoint of electromagnetic properties and structure of the strip transducer.

Development of Tomograph Technique for Evaluating Thickness Reduction using Noncontact Ultrasonic Sensor Network (두께감육 평가를 위한 비접촉식 초음파 센서 네트워크를 이용한 토모그래프 기술 개발)

  • Lee, J.M.;Kim, Y.K.;Park, I.K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • This paper describes a tomographic imaging technique for evaluating the thickness reduction of a plate-like structure using a noncontact sensor network based on an electromagnetic acoustic transducer that generates shear horizontal plate waves. Because this technique is based on the effect of mode cutoff and time of flight of guided waves caused by a change in thickness, the tomographic image provides information on the presence of defects in the structure. To verify the performance of the method, artificial defects with various thickness reduction ratios were machined in an aluminum plate, and the tomographic imaging results are reported. The results show that the generated tomographic image displays the thickness reductions and can identify their locations. Therefore, the proposed technique has good potential as a tool for health monitoring of the integrity of plate-like structures.

Nondestructive Evaluation Using Electromagnetic-Acoustic Transducer (Electromagnetic-Acoustic Transducer를 이용한 비파괴평가)

  • Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.278-284
    • /
    • 1997
  • EMAT는 비접촉으로 초음파를 송수신 할 수 있는 탐촉자로서 시험체와 탐촉자간의 접촉을 위한 매개 물질이 필요치 않으므로, 움직이고 있는 물체에 초음파탐상법을 적용하고자 하는 분야와 초음파의 속도를 정밀하게 측정하고자 하는 분야에 주로 응용된다. 구체적으로는 길이가 긴 튜브류의 결함 탐상, 용접중인 재료의 용접상태 감시, 기차바퀴 및 레일의 결함 탐상, 고온상태인 재료의 결함 탐상 등이 비접촉 특성을 이용하여 적용될 수 있는 분야이며, 재료의 집합조직 및 소성이방성의 측정, 재료의 미세조직 및 기계적 강도의 예측, 그리고 잔류응력의 측정 등이 정밀한 초음파속도 및 감쇠의 측정으로부터 적용될 수 있는 분야이다. EMAT가 일반적인 접촉식초음파탐상법에 비하여 특별한 분야에의 응용에 큰 장점을 가지고 있지만, 낮은 에너지 전환효율, 넓은 불감영역, 그리고 사용주파수의 한계 등의 문제를 가지고 있기 때문에 기존의 접촉식 방법의 적용이 용이한 분야에의 적용은 필요하지 않다. 그러나 특별한 목적과 용도에의 적용 필요성이 생길 경우에는 적절한 연구를 통하여 알맞은 탐촉자를 제작하고 탐상 방법을 개발함으로서 본래의 목적에 알맞은 탐상이 수행될 수 있다.

  • PDF

MODE CONTROL OF GUIDED WAVE IN MAGNETIC HOLLOW CYLINDER USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER ARRAY

  • FURUSAWA, AKINORI;KOJIMA, FUMIO;MORIKAWA, ATSUSHI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.196-203
    • /
    • 2015
  • The aim of this work is to demonstrate a method for exciting and receiving torsional and longitudinal mode guided waves with an electromagnetic acoustic transducer (EMAT) ring array. First of all, a three-dimensional guided wave simulator is developed in order to numerically analyze the propagation of the guided wave. The finite difference time domain method is used for the simulator. Second, two guided wave testing systems using an EMAT ring array are provided: one is for torsional mode (T-mode) guided wave and the other is for longitudinal mode (L-mode). The EMATs used in the both systems are the same in design. A method to generate and receive the T- and L-mode guided waves with the same EMAT is proposed. Finally, experimental and numerical results are compared and discussed. The results of experiments and simulation agree well, showing the potential of the EMAT ring array as a mode controllable guided wave transmitter and receiver.