• Title/Summary/Keyword: electromagnetic apparatus

Search Result 68, Processing Time 0.025 seconds

Optimal Design of Permanent Magnetic Actuator for Permanent Magnet Reduction and Dynamic Characteristic Improvement using Response Surface Methodology

  • Ahn, Hyun-Mo;Chung, Tae-Kyung;Oh, Yeon-Ho;Song, Ki-Dong;Kim, Young-Il;Kho, Heung-Ryeol;Choi, Myeong-Seob;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.935-943
    • /
    • 2015
  • Permanent magnetic actuators (P.M.A.s) are widely used to drive medium-voltage-class vacuum circuit breakers (V.C.B.s). In this paper, a method for design optimization of a P.M.A. for V.C.B.s is discussed. An optimal design process employing the response surface method (R.S.M.) is proposed. In order to calculate electromagnetic and mechanical dynamic characteristics, an initial P.M.A. model is subjected to numerical analysis using finite element analysis (F.E.A.), which is validated by comparing the calculated dynamic characteristics of the initial P.M.A. model with no-load test results. Using tables of mixed orthogonal arrays and the R.S.M., the initial P.M.A. model is optimized to minimize the weight of the permanent magnet (P.M.) and to improve the dynamic characteristics. Finally, the dynamic characteristics of the optimally designed P.M.A. are compared to those of the initially designed P.M.A.

The Study of Induction Heating Apparatus with High Efficiency (고효율 유도가열 전열장치 개발에 관한 연구)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.185-189
    • /
    • 2016
  • Energy-saving heat depending on the country's rise in oil prices up to the product development is regarded as pending issues. Therefore, in recent years, been a continuing research studies developed for increasing the economic efficiency and reliability achieved in effectively using the side of the energy for heating using electrical to address these problems and, in particular made active the technology developed for high performance and renal material becoming. This paper is to study the development of highly efficient induction heating device according to the excellent heat transfer characteristics for energy transfer. Induction heating is used as the phenomenon of electromagnetic induction, such as heat transfer conduction or convection of the existing methods are no different. Medium heat without beating is absorbed directly into the water column switched rapidly, have features that heats evenly. In addition, high-frequency induction heating in a variety of frame designs. Heating element heats only when utilized properly, it is possible to heat the focus.

Effects of 835-MHz Radiation on the Intracellular Calcium, Reactive Oxygen Species, and F-actin Polymerization in Rat-2 Fibroblasts

  • Hong Sae-Yong;Lee Zee-Won;Son Tae-Ho;Chang Sung-Keun;Choi Jong-Soon
    • Biomedical Science Letters
    • /
    • v.12 no.1
    • /
    • pp.9-16
    • /
    • 2006
  • We investigated the effects of 835-MHz electromagnetic field (EMF), one of the most popular communication frequency band in Korean code-division multiple-access (CDMA) mobile phone system, on cellular signal transduction. For this, we examined the change of intracellular calcium $([Ca^{2+}]_i)$, reactive oxygen species (ROS) and F-actin polymerization after exposure to 835-MHz EMF followed by the treatment of agonists in Rat-2 fibroblast cells. Culture cells were pretreated with serum-tree medium and concomitantly exposed to 835-MHz at specific absorption rate (SAR) of 4.0 W/kg for 24 hr in a specialized designed apparatus based on Transverse Electro Magnetics (TEM) wave theory. Intracellular $Ca^{2+}$ responses to lysophosphatidic acid (LPA) and epidermal growth factor (EGF) in Rat-2 fibroblast after exposure to 835-MHz EMF were shown to be similar pattern as observed in normal cultured cells. However, the LPA-induced calcium spiking was slightly delayed to 7 sec and sustained thereafter to a little higher ground level under 835-MHz EMF radiation compared to unexposed cells. ROS production level by LPA in the exposed cells was not different from that in control. Furthermore, LPA induced the production of stress fibers with no significant difference in the exposed and unexposed cells. These results suggest that mobile phone radiation (835-MHz, SAR 4.0 W/kg) may not be directly related to signal transduction in Rat-2 fibroblasts except the slight effect of calcium spiking in LPA-induced cells but remain to be further elucidated for possible indirect intervention.

  • PDF

Design of a Magnetic Field Source for In Vivo Experiments at Extremely Low Frequency (생체 실험용 극저주파 자기장 발생 장치의 설계)

  • 김정호;김윤명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.871-877
    • /
    • 2003
  • In this paper, the design parameters for the magnetic field source at extremely low frequency are proposed. This facility can be used fur in vivo experiments with small animals to investigate biological response to the driving magnetic fields. In case that the exposed animals are motionless, the animals may be affected by the directivity of driving field. To avoid this effect, a 2-axis ELF magnetic field driving apparatus was designed. The optimum location and number of turns of each coil were obtained by numerical analysis. Applying these data to the MATLAB code(for computation), the magnetic field distribution was obtained. The calculation result fur a well-designed facility showed that the space in which the amplitude of the magnetic field lies within the 95 % of the magnetic field distribution was more than 60 % of each axis length.

Electric Fuel Sender Apparatus for the Vehicles Using CPW Transmission Line (CPW 전송선을 이용한 전자식 자동차용 연료 센더 장치)

  • Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.380-386
    • /
    • 2006
  • Electric fuel sender fur the vehicle fuel gauge system was designed and fabricated based on the CPW(Co-Planer Waveguide) transmission line theory. It is applied on this system that characteristic impedance of RF transmission line can be varied by the surrounded material of the line. By the characteristic impedance owing the level of gasoline or diesel fuel in vehicle fuel tank, CPW line has corresponding reflected signal as much as changed impedance. Detected signal is amplified, and delivered to fuel indicator into cluster unit on dash board. Conventional floating mechanical buoy level gauge has several defects as low reliability and high break down rate by mechanical operation, and has not good linearity for the fuel level difference. CPW line with electric circuits are constructed on 1.6 mm thickness epoxy substrate, and measurement shows that this system has more accurate level and better linearity than conventional mechanical system. New electric fuel sender which has good productivity with long lifetime and low-in-cost by the SMT chip assembling could be replaced this system with conventional floating buoy system.

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

Development and Application of Penetration Type Field Shear Wave Apparatus (관입형 현장 전단파 측정장치의 개발 및 적용)

  • Lee, Jong-Sub;Lee, Chang-Ho;Yoon, Hyung-Koo;Lee, Woo-Jin;Kim, Hyung-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.67-76
    • /
    • 2006
  • The reasonable assessment of the shear stiffness of a dredged soft ground and soft clay is difficult due to the soil disturbance. This study addresses the development and application of a new in-situ shear wave measuring apparatus (field velocity probe: FVP), which overcomes several of the limitations of conventional methods. Design concerns of this new apparatus include the disturbance of soils, cross-talking between transducers, electromagnetic coupling between cables, self acoustic insulation, the constant travel distance of S-wave, the rotation of the transducer, directly transmitted wave through a frame from transducer to transducer, and protection of the transducer and the cable. These concerns are effectively eliminated by continuous improvements through performing field and laboratory tests. The shear wave velocity of the FVP is simply calculated, without any inversion process, by using the travel distance and the first arrival time. The developed FVP Is tested in soil up to 30m in depth. The experimental results show that the FVP can produce every detailed shear wave velocity profiles in sand and clay layers. In addition, the shear wave velocity at the tested site correlates well with the cone tip resistance. This study suggests that the FVP may be an effective technique for measuring the shear wave velocity in the field to assess dynamic soil properties in soft ground.

Detection of Levitated Ring using Photo Sensor and Construct of an Education System (광센서를 이용한 점핑링의 위치검출과 교육용 시스템 제작)

  • Park, Seong-Wook
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.365-370
    • /
    • 2002
  • The jumping ring apparatus described in this study is used to demonstrate and educate the effects of electromagnetic induction. Placing an aluminum ring over the core and switching on AC source causes the ring to jump in the air due to induced currents in the ring producing a magnetic field opposed to that produced in the core. This force is a function of flux density, ac current of ring and levitated height of the ring. Using photo sensor arrays, detect the ring position and represent the position of the ring to analog voltage for an education performance. This paper presents modelling of the jumping ring system and shows how does control signal generate in order to follow desired position.

Using the TDR in Dielectric for Partial Discharge Signals Detection Method (이종 비유전율에서 TDR을 이용한 PD발생 위치 추적방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1374-1379
    • /
    • 2015
  • Time Domain Reflectometry(TDR) using microwave bands, including broadband spectrum that occurs at the range of rates that start between partial discharge position it easier to make the techniques that could be measured. Partial discharge in the Gas Insulated Switchgear(GIS), the dielectric constant in the band more than GHz different the insulating material if you want to organize, and the insulating material regardless of how partial discharge position in the SF6 gas Partial Discharge by applying the heritability estimated its position, but the position error occurred about 23 percent of the existing way, correct in not suitable location tracking the outbreak PD. This technique the rate of other dielectric that make up the power apparatus heterology is measured at the function to slow the progression of the electromagnetic waves apart by calculating the partial discharge as the location, A simple way to track. Dielectric using other methods proposed new structure can calculate the speed of heritability PD is occurring can measure.

Comparative Analysis of Day and Night Time Video Accuracy to Calculate the Flood Runoff Using Surface Image Velocimeter (SIV) (표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 주·야간영상의 정확도 비교분석)

  • Kim, Yong-Seok;Yang, Sung-Kee;Yu, Kwonkyu;Kim, Dong-Su
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.359-369
    • /
    • 2015
  • This study analyzed the velocimetry of runoff and measured the flood discharge by applying the SIV (Surface Image Velocimetrer) to the daytime and nighttime flow image data with special reference to Seong-eup Bridge at Cheonmi stream of Jeju during the flow by the severe rainstorm on May 27, 2013. A 1000W lighting apparatus with more than 150 lux was installed in order to collect proper nighttime flow image applied to the SIV. Its value was compared and analyzed with the velocity value of the fixed electromagnetic wave surface velocimetry (Kalesto) at the same point to check the accuracy and applicability of the measured velocity of flow. As a result, determination coefficient $R^2$ values were 0.891 and 0.848 respectively in line with the velocity distribution of the daytime and nighttime image and the flow volume measured with Kalesto was approximately 18.2% larger than the value measured with the SIV.