• 제목/요약/키워드: electromagnetic apparatus

검색결과 68건 처리시간 0.027초

레이저를 이용한 전력설비 진단용 광전송 시스템 개발 (Development of Optical Transmission System for The Diagnosis of Power Apparatus Using Laser Beam)

  • 홍진영;조광래;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.275-277
    • /
    • 1993
  • It is practically required to develop an optical transmission system, for the diagnosis of electric power apparatus, which enables to distinguish the right signals related to the partial discharge taken place inside the apparatus. These partial discharges are transformed into ultra sonic signals by the sensor and then used for the voltage application to pokels cell. Afterwards, the modulated laser beam is transmitted through the optical fiber. Throughout this work, a laser-beam based detecting system is developed and permits us to reproduce the transmitted signals indirectly without electromagnetic interference. For this purpose the characteristics of this system is well analyzed by means of different type of signals from function generator.

  • PDF

유한요소해석을 통한 전자기 성형장비 공정변수의 성형력에 미치는 영향 (Effect of Process Parameters in Electromagnetic Forming Apparatus on Forming Load by FEM)

  • 노학곤;박형규;송우진;강범수;김정
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.733-740
    • /
    • 2013
  • The high-velocity electromagnetic forming (EMF) process is based on the Lorentz force and the energy of the magnetic field. The advantages of EMF include improved formability, wrinkle reduction, and non-contact forming. In this study, numerical simulations were conducted to determine the practical parameters for the EMF process. A 2-D axis-symmetric electromagnetic model was used, based on a spiral-type forming coil. In the numerical simulation, an RLC circuit was coupled to the spiral coil to measure various design parameters, such as the system input current and the electromagnetic force. The simulation results show that even though the input peak current levels were at the same level in each case, the forming condition varied due to differences in the frequency of the input current. Thus, the electromagnetic forming force was affected by the input current frequency, which in turn, determined the magnitude of the current density and the magnetic flux density.

고체절연체의 연면방전에 따른 방사전자파 분포 특성 (The Characteristics of Electromagnetic waves by surface discharge in solid insulator)

  • 김충년;이현동;김기채;박원주;이광식;이동인;이춘하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1862-1864
    • /
    • 2000
  • Recently diagnostic techniques have been investigated to detect a partial discharge(PD) associated with a dielectric material defect in a high-voltage electrical apparatus. Among the PD measuring method, detecting electromagnetic wave generated by PD is one of the most effective method because PD radiates wide frequency of electromagnetic wave up to UHF. From the above points of view, we have investigated the polarization and distance characteristics of electromagnetic wave radiated by an insertion of solid insulators between needle-plane electrodes in the air. According to the magnitude of applied voltage, the frequency spectrum of radiated electromagnetic waves were increased about under 100(MHz), compared with background noise. The electromagnetic wave magnitude is attenuated about 4$\sim$7.6[dB] at the point 3[m] away from PD.

  • PDF

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구 (A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus)

    • 장한솔;정우령;문정현;최성경;성원석;황민섭;이승덕;김경호;윤종화;김은정
      • 대한한의학회지
      • /
      • 제43권3호
      • /
      • pp.150-163
      • /
      • 2022
    • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

    전자력을 이용한 평면 진동형 각속도계의 자속간섭의 영향 (The effect of magnetic flux interference on the planar vibratory gyroscope driven by electromagnetic force)

    • 홍승완;이상훈;임형택;김용권;이승기
      • 대한전기학회:학술대회논문집
      • /
      • 대한전기학회 1995년도 하계학술대회 논문집 C
      • /
      • pp.1425-1427
      • /
      • 1995
    • The effect of the magnetic flux interference between the driving and detecting unit of the gyroscope by the electromagnetic force has been investigated quantitatively. The key parameter dictating the output characteristics of the gyroscope which is driven and detected using electromagnetic force is the mutual interference between the driving and detecting unit. Using the specially designed apparatus for positioning of the detecting unit, it is found that the vertical positioning of the detecting unit plays a significant role in minimizing the interference effect as evidenced by our experimental results.

    • PDF

    ISM 밴드용 임베디드 기기를 위한 전자기 혼신신호의 송신전력 제한치 도출 (Calculating Emission Power Limits of Electromagnetic Disturbance Signal for Embedded Systems in ISM Bands)

    • 조면균;김식
      • 대한임베디드공학회논문지
      • /
      • 제5권3호
      • /
      • pp.136-143
      • /
      • 2010
    • Embedded systems widely used for wireless communication such as W-LAN, Bluetooth and ZigBee operate on ISM (Industrial, Scientific and Medical) band but they can be seriously affected by electromagnetic interference radiated from ISM apparatus. Therefore C.I.S.P.R. reports proposed limits for the protection of telecommunication from interference from ISM equipment. In this paper, we clarify the methods for calculating limits for disturbance signal for Embedded Systems in ISM band and propose simple way of calculating limits for interference signal in both above and below 1 GHz band cases.

    Characteristics of the Voltages between the Communication Lines and Ground Induced by the Adjacent Artificial High-Voltage or Current ELF Source

    • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong;Eun, Chang-Soo;Gimm, Yoon-Myoung
      • Journal of electromagnetic engineering and science
      • /
      • 제9권4호
      • /
      • pp.175-181
      • /
      • 2009
    • The measurements were performed to verify experimentally that the voltage arising on a telecommunication line by a power line is due to the induction phenomena because there has been an opinion that the arising voltage on a telecommunication line is not by induction, but by other causality. The voltage appeared on the telecommunication line by way of an electric field or magnetic field generated by the source apparatus that had been artificially made to provide intentional constant high-voltage or current in ELF, that is, 60 Hz as an emulated commercial power.

    A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Slit In a Nearby Conducting Screen for Near-Field Scanning Microscopy

    • Lee, Jong-Ig;Cho, Young-Ki
      • Journal of electromagnetic engineering and science
      • /
      • 제9권2호
      • /
      • pp.105-109
      • /
      • 2009
    • The problem of electromagnetic coupling between a slit fed by a flanged parallel-plate waveguide(PPW) and a slit in an infinite nearby conducting screen parallel to the flanged ground conductor is studied as a simplified problem for a near-field scanning microscopy(NSM). The method of moments isused to solve the coupled integral equations for the electric field distributions over the slits. The performance of the proposed apparatus as an NSM is tested by examining the effects of some geometrical parameters on the equivalent slit admittance and coupled powers through the slits.

    Nondestructive Evaluation of Residual Life of 1Cr-1Mo-0.25V Steel from Reversible Magnetic Permeability

    • K.S. Ryu;S.H. Nahm;Kim, Y.I.;K.M. Yu;Kim, Y.B.;Cho, Y.;D. Son
      • Journal of Magnetics
      • /
      • 제6권1호
      • /
      • pp.27-30
      • /
      • 2001
    • We present a new procedure to evaluate the residual life of 1Cr-1Mo-0.25V steel from reversible magnetic permeability. The method is based on the existence of first harmonics in the differential magnetization around the coercive force. The apparatus is based on the detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the exciting coil. Results obtained for the first harmonics and Vickers hardness on aged samples show that the peak interval of reversible permeability and Vickers hardness decrease as aging time increases. The correlation between Vickers hardness and the peak interval of the reversible permeability may be used to evaluate the residual life of 1Cr-lMo-0.25V steel, nondestructively.

    • PDF