• Title/Summary/Keyword: electrolyte concentration

Search Result 686, Processing Time 0.032 seconds

Development of catalyst-substrate integrated copper cobalt oxide electrode using electrodeposition for anion exchange membrane water electrolysis (전착법을 이용한 촉매-기판 일체형 구리 코발트 산화물 전극 개발 및 음이온 교환막 수전해 적용)

  • Kim, Dohyung;Kim, Geul Han;Choi, Sung Mook;Lee, Ji-hoon;Jung, Jaehoon;Lee, Kyung-Bok;Yang, Juchan
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.3
    • /
    • pp.180-186
    • /
    • 2022
  • The production of hydrogen via water electrolysis (i.e., green hydrogen) using renewable energy is key to the development of a sustainable society. However, most current electrocatalysts are based on expensive precious metals and require the use of highly purified water in the electrolyte. We demonstrated the preparation of a non-precious metal catalyst based on CuCo2O4 (CCO) via simple electrodeposition. Further, an optimization process for electrodeposition potential, solution concentration and electrodeposition method was develop for a catalyst-substrate integrated electrode, which indicated the highly electrocatalytic performance of the material in electrochemical tests and when applied to an anion exchange membrane water electrolyzer.

Prevalence and factors associated with hyponatremia in older adults who visited emergency department (응급실을 방문한 노인 환자의 저나트륨혈증 유병률 및 위험인자 분석)

  • Kim, Geonnyeon;Shin, Sangmi;Suh, Yewon;Namgung, Hyungwook;Lee, Jeonghwa;Lee, Euni;Lee, Ju-Yeun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.2
    • /
    • pp.67-73
    • /
    • 2022
  • Objectives: Hyponatremia is prevalent electrolyte disorder and can be fatal in older adults. Evaluative studies on hyponatremia among older adults are scarce, especially targeting for those who visited emergency department (ED). We aimed to estimate the prevalence and to identify risk factors of hyponatremia among elderly patients visiting the ED. Methods: A retrospective chart review was completed including 65 or older patients who visited ED at Seoul National University Bundang Hospital from September to December 2019. Patients with the serum sodium concentration of less than 130mEq/L was defined as a hyponatremia group. Logistic regression analysis was conducted to assess predictive factors for hyponatremia. Results: Of the total 2,445 patients, 155 (6.3%) were confirmed to have hyponatremia at the time of ED visits. Risk factors for hyponatremia identified in logistic regression analysis were thiazides (aOR=2.64, 95% CI 1.66-4.21), opioids (exclude tramadol) (aOR=3.45, 95% CI 1.72-6.94), and desmopressin (aOR=6.98, 95% CI 2.45-19.84). Compared to the use of thiazides alone, it was confirmed that the possibility of hyponatremia was more than quadrupled when proton pump inhibitor (PPI) was used together (aOR=4.08, 95% CI 1.74-9.55). Conclusions: About 6.3% of older adults visiting the ED had hyponatremia. Age, number of medications taken, previous history of hyponatremia, heart failure, cirrhosis, pneumonia, sepsis, prescribed drugs including thiazides, opioids (exclude tramadol), or desmopressin or taking PPI together with thiazides was confirmed to correlate with the risk of hyponatremia.

Effect of Indirect Oxidation on the Design of Sewage/wastewater Reuse System with an Electrolysis Reactor (전기분해 반응조의 간접산화 효과가 하.폐수 재활용 시스템 설계에 미치는 영향)

  • Shin, Choon-Hwan
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • In this paper, we investigated the effect of an indirect oxidation zone in an electrolysis reactor that used Ti/$IrO_2$ as the anode and SUS 316L as the cathode. Based on our preliminary results, the electrolysis reactor was operated with pole plate interval of 6 mm, current density 1.0 $A/dm^2L$ and electrolyte concentration 15%. The removal efficiency, COD (chemical oxygen demand), was additionally increased by 55% and 12.5${\sim}$15.0% in the direct and indirect oxidation zones, respectively. The removal efficiencies of T-N (total nitrogen) and T-P (total phosphorus) were found to be 88% and 75%, respectively. It was shown that the additional effect of the indirect oxidation zone on the removal was nearly negligible. Also, as the removal of COD,T-N and T-P took place during the initial2${\sim}$5 days of reaction, it was concluded that there was no need to extend the retention time of the electrolysis reactor.

Effect of Several Treatments on Chilling Injury of Paprika Fruits during Low Temperature Storage (몇 가지 처리가 파프리카 과실의 저온장해에 미치는 영향)

  • Choi, In-Lee;Lee, Yong Beom;Kim, Il Seop;Baek, Jun Pill;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.427-431
    • /
    • 2013
  • Paprika fruits should be stored and distributed at above $7^{\circ}C$ to prevent chilling injury but the small amount of paprika that transports with other horticultural products in refrigerated container by ship usually stored less than $5^{\circ}C$ for other products. In this case, paprika fruits cannot help exposing chilling temperature, so that the paprika must be lost marketable value during a long period of transfer. This study was conducted to compare the alleviated effects of high $CO_2$ treatment (passive MAP), heat (hot water dipping), and UVc treatment on chilling injury of paprika fruits due to low temperature storage, and also to decide if these treatments can be used for transporting under $5^{\circ}C$. After each treatment the paprika were put in the low temperature storage ($4^{\circ}C$) for 20 days and afterwards change the in room temperature ($20^{\circ}C$) for 5 days. The fresh weight loss of all the treatments except the high $CO_2$ treatment showed around 7~12% after 25 days of storage and the ethylene concentration showed periodical increases and decreases as around 3 ${\mu}l/l$. The $CO_2$ concentration was rapidly increased 33% carbon dioxide in high $CO_2$ treatment during room temperature storage after cold storage for 20 days. The firmness which is key quality characteristics during storage and is decreasing caused by chilling injury was not significantly different among all treatments. However, the firmness of stored paprika was maintained highest in the treated with hot water dipping. Therefore, HWD and UVc treatment that showed 60% of electrolyte leakage in the $4^{\circ}C$ control (chilling injury control) and similar level with the $7^{\circ}C$ control (non-chilling injury control) would be effective to alleviate chilling injury in the stored paprika.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Electrochemical Treatment of Dye Wastewater Using Fe, RuO2/Ti, PtO2/Ti, IrO2/Ti and Graphite Electrodes (RuO2/Ti, PtO2/Ti, IrO2/Ti 및 흑연전극을 이용한 염료폐수의 전기화학적 처리)

  • Kim, A Ram;Park, Hyun Jung;Won, Yong Sun;Lee, Tae Yoon;Lee, Jae Keun;Lim, Jun Heok
    • Clean Technology
    • /
    • v.22 no.1
    • /
    • pp.16-28
    • /
    • 2016
  • Textile industry is considered as one of the most polluting sectors in terms of effluent composition and volume of discharge. It is well known that the effluents from textile dying industry contain not only chromatic substances but also large amounts of organic compounds and insolubles. The azo dyes generate huge amount of pollutions among many types of pigments. In general, the electrochemical treatments, separating colors and organic materials by oxidation and reduction on electrode surfaces, are regarded as simpler and faster processes for removal of pollutants compared to other wastewater treatments. In this paper the electrochemical degradation characteristics of dye wastewater containing CI Direct Blue 15 were analyzed. The experiments were performed with various anode materials, such as RuO2/Ti, PtO2/Ti, IrO2/Ti and graphite, with stainless steel for cathode. The optimal anode material was located by changing operating conditions like electrolyte concentration, current density, reaction temperature and initial pH. The degradation efficiency of dye wastewater increased in proportion to the electrolyte concentration and the current density for all anode materials, while the temperature effect was dependent on the kind. The performance orders of anode materials were RuO2/Ti > PtO2/Ti > IrO2/Ti > graphite in acid condition and RuO2/Ti > IrO2/Ti > PtO2/Ti > graphite in neutral and basic conditions. As a result, RuO2/Ti demonstrated the best performance as an anode material for the electrochemical treatment of dye wastewater.

Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F (전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서)

  • Sung Eun Ji;Sang Hyuk Lee;Hye Jin Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.258-263
    • /
    • 2023
  • In this study, conductive polymers and the enzyme tyrosinase (Tyr) were deposited on the surface of a screen printed carbon electrode (SPCE), which can be fabricated as a disposable sensor chip, and applied to the detection of bisphenol F (BPF), an endocrine disruptor with proven links to male diseases and thyroid disorders, using electrochemical methods. On the surface of the SPCE working electrode, which was negatively charged by oxygen plasma treatment, a positively charged conductive polymer, poly(diallyldimethyl ammonium chloride) (PDDA), a negatively charged polymer compound, poly(sodium 4-styrenesulfonate) (PSS), and another layer of PDDA were layered by electrostatic attraction in the order of PDDA, PSS, and finally PDDA. Then, a layer of Tyr, which was negatively charged due to pH adjustment to 7.0, was added to create a PDDA-PSS-PDDA-Tyr sensor for BPF. When the electrode sensor is exposed to a BPF solution, which is the substrate and target analyte, 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione) is generated by an oxidation reaction with the Tyr enzyme on the electrode surface. The reduction process of the product at 0.1 V (vs. Ag/AgCl) generating 4,4'-methylenebis(benzene-1,2-diol) was measured using cyclic and differential pulse voltammetries, resulting in a change in the peak current with respect to the concentration of BPF. In addition, we compared the detection performance of BPF using an ionic liquid electrolyte as an alternative to phosphate-buffered saline, which has been used in many previous sensing studies. Furthermore, the selectivity of bisphenol S, which acts as an interfering substance with a similar structure to BPF, was investigated. Finally, we demonstrated the practical applicability of the sensor by applying it to analyze the concentration of BPF in real samples prepared in the laboratory.

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

The Effect of Cheonmagudeng-um gagam(CGG) on Spontaneous Hypertensive Rat(SHR) (천마구등음가감(天麻鉤藤飮加減)이 고혈압 유관인자 및 SHR 병태모델에 미치는 영향)

  • Song, Byoung-Yong;Choi, Eun-Hee;Jung, Tae-San;Kang, Seong-Sun;An, Ga-Yong;Kim, Oh-Young;Jeon, Sang-Yun;Hong, Seok
    • The Journal of Internal Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.345-360
    • /
    • 2011
  • Objectives : This study was examined to investigate the effects of Cheonmagudeng-um gagam (CGG) extract on spontaneous hypertension. Methods : For the study of CGG, we divided rats into three groups. The normal group was Wister Kyoto rats (WKY). The control group was spontaneously hypertensive rats (SHR). The treatment group was SHR which were administered CGG extract (SHR-CGG). SHR-CGG were orally administered CGG extract that was diluted in distilled water at the various concentrations for 4 weeks (234.5 mg/kg) and SHR were orally administered the same dosage of plain distilled water as SHR-CGG. Then we measured anti-oxygen effects, ACE inhibitory activity, weight of heart and kidney, blood pressure, heart rate, plasma aldosterone, electrolyte, creatinine, uric acid, BUN, and observed the cortex of the cardiac muscle, kidney, and adrenal gland. Results : CGG increased DPPH scavenging activity and SOD similar activity depending on the concentration. CGG significantly decreased ROS, TNF-${\alpha}$, IL-6, IL-$1{\beta}$, heart weight, blood pressure, heart rate, aldosterone, and BUN in SHR. CGG increased ACE inhibition activity depending on the concentration. CGG inhibited the heart, kidney and adrenal gland tissue injury that is caused by hypertension. Conclusions : These results suggest that CGG is effective in treatment and prevention of hypertension.

Electrochemical Degradation of Phenol by Using Reticulated Vitreous Carbon Immobilized Horseradish Peroxidase (Horseradish Peroxidase가 고정화된 다공성 탄소 전극을 이용한 페놀의 전기화학적 분해)

  • Cho, Seung-Hee;Yeon, Kyeong-Ho;Kim, Gha-Young;Shim, Joon-Mok;Moon, Seung-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1263-1269
    • /
    • 2005
  • Horseradish peroxidase, had the phenol degradation rate of 95% in aqueous phase, was covalently immobilized on the surface of reticulated vitreous carbon(RVC) and the degradation of phenol was performed with in situ generated $H_2O_2$-immobilized HRP complex in an electrochemical reactor. The incorporation of carboxylic group on the RVC surface was confirmed by FT/IR spectrometry and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride(EDC) was used for peptide bonds between the carboxylic groups on the RVC surface and amine groups from HRP. The optimal conditions of in situ $H_2O_2$ generation such as concentration($10{\sim}200$ mM) and pH($5.0{\sim}8.0$) of electrolyte, supply of $O_2(10{\sim}50$ mL/min) and applied voltage($-0.2{\sim}-0.8$ volt, vs. Ag/AgCl) from potentiostat/galvanostat were determined by concentration of hydrogen peroxide and current efficiency. It was observed that the RVC immobilized HRP was stable maintaining 89% of the initial activity during 4 weeks. The phenol degradation rate of 86% was attained under the optimal condition of in situ $H_2O_2$ generation.