• Title/Summary/Keyword: electrodeposited

Search Result 340, Processing Time 0.03 seconds

Electrodeposition of GMR Ni/Cu Multilayers in a Recirculating Electrochemical Flow Reactor

  • Rheem, Young-Woo
    • Korean Journal of Materials Research
    • /
    • v.20 no.2
    • /
    • pp.90-96
    • /
    • 2010
  • The recirculating electrochemical flow reactor developed at UCLA has been employed to fabricate nanostructured GMR multilayers. For comparison, Ni/Cu multilayers have been electrodeposited from a single bath, from dual baths and from the recirculating electrochemical flow reactor. For a magnetic field of 1.5 kOe, higher GMR (Max. -5%) Ni/Cu multilayers with low electrical resistivity (< $10\;{\mu}{\Omega}{\cdot}cm$) were achieved by the electrochemical flow reactor system than by the dual bath (Max. GMR = -4.2% and < $20\;{\mu}{\Omega}{\cdot}cm$) or the single bath (Max. GMR = -2.1% and < $90\;{\mu}{\Omega}{\cdot}cm$) techniques. Higher GMR effects have been obtained by producing smoother, contiguous layers at lower current densities and by the elimination of oxide film formation by conducting deposition under an inert gas environment. Our preliminary GMR measurements of Ni/Cu multilayers from the electrochemical flow reactor obtained at low magnetic field of 0.15 T, which may approach or exceed the highest reported results (-7% GMR) at magnetic fields > 5 kOe.

Characterization of High Temperature Oxide Scales formed on Ni-18%W Coatings (Ni-18%W 코팅의 고온산화막 분석)

  • Ko J. H;Lee D. B
    • Korean Journal of Materials Research
    • /
    • v.14 no.4
    • /
    • pp.281-286
    • /
    • 2004
  • The oxide scales formed on Ni-18W(at.%) coating that was electrodeposited on steel were investigated using XRD, SEM and TEM. The oxide scales consisted mainly of an outer NiO layer, and an inner thick ($NiWO_4$+NiO) mixed layer. The unoxidized coating below the oxide scale was rich in Ni and depleted in W, owing to the consumption of Wand the resultant Ni enrichment. The oxidation resistance of Ni-18W coating was poorer than that of the TiN coating, due to the formation of nonprotective NiWO$_4$. During oxidation, Ni and the substrate element of Fe diffused outward, while oxygen inward, according to the concentration gradients.

A study on the Interfacial Properties of Electrodeposited Single Carbon Fiber/Epoxy Composites Using Tensile and Compressive Fragmentation Tests

  • Park, Joung-Man;Kim, Jin-Won
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Interfacial and microfailure properties of carbon fiber/epoxy composites were evaluated using both tensile fragmentation and compressive Broutman tests. A monomeric and two polymeric coupling agents were applied via the electrodeposition (ED) and the dipping applications. A monomeric and a polymeric coupling agent showed significant and comparable improvements in interfacial shear strength (IFSS) compared to the untreated case under both tensile and compressive tests. Typical microfailure modes including cone-shaped fiber break, matrix cracking, and partial interlayer failure were observed under tension, whereas the diagonal slipped failure at both ends of the fractured fiber appeared under compression. Adsorption and shear displacement mechanisms at the interface were described in terms of electrical attraction and primary and secondary bonding forces.

The Effects Influenced on the Magnetic Properties by Depositing Fe-C in the Bottom Extremity of the Co-Fe Electrodeposited Anodic Oxidized Films (Co-Fe 석출 양극산화피막의 초기석출부에 석출한 Fe-C가 자기특성에 미치는 영향)

  • Kang, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1295-1297
    • /
    • 1994
  • At 34 at% Co-Fe, the aluminum anodic oxidized (alumite) films of particle diameter $150{\AA}$ have large perpendicular anisotropy energy and high coercive force. However, for the samples of particle diameter larger than $450{\AA}$, the bottom of each particle forms abnormal part called branch-shaped different from that of particle diameter $150{\AA}$. In this case the magnetic anisotropy energy Ku was about zero at the compositions of 45 and 75 at% Co. Furthermore, at tile compositions from 50 to 70 at% Co, the values of Ku became negative value. We confirmed that Fe-C deposited the bottom of particle orients very strongly and it has a large influence upon the magnetic anisotropy energy.

  • PDF

Characteristics of Cryolite as an Electrolyte for Reduction of Nd$_2$O$_3$ (네오디뮴 산화물의 전해환원시 전해질로서 빙정석의 특성)

  • 남상욱;백영현
    • Journal of Surface Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.82-86
    • /
    • 1993
  • An attempt was made to reduce directly Nd2O3 in a cryolited based fluoride bath. Neodymium metal was electrodeposited on the iron cathode to produce the Fe-Nd eutectic alloy in a liquid state at 90$0^{\circ}C$. Graphite was adopted for the anode and pure iron for the cathode. Electrolyte was composed of Na3AlF6 50wt.%. AlF3 34wt.% and Nd2O3 16wt.%. Analysis of typical alloy product showed Al 63.4wt.% Fe 26.9wt.% and Nd 7.0 wt.% The enrichment of neodymium in the alloy couldn't be obtained because aluminum codeposited with ne-odydmium. Experimental results proved that the cryolited based electrolyte was unstable for the electrolysis of rare earth oxides even though their prominent solubilities.

  • PDF

Effects of structure and morphology of anodized Al thin film on magnetic properties (알루미늄 양극산화 피막의 구조 및 형상이 자기적 특성에 미치는 영향)

  • 권용덕;박용수
    • Journal of Surface Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.45-54
    • /
    • 1993
  • In this study, magnetic properties of anodized Al film deposited with ferro-magnetic metals in the capacity of perpendicular magnetic recording media were measured and evaluated to find out the role of structure and morphology of the oxide films on magnetic characteristics. The object of this work was to present the conditions of magnetic thin film formation with more superior magnetic property. Anodizing was carried out under various conditions, and then the anodized film were electro-deposited with Co, Ni, Fe and their alloys. Coercive force and residual magnetization in perpendicular direction increased as the pore length of anodized film increased. It was attributed to the increase of the amount of depoisted metals and the ratio of length/diameter of pores. Morphology of anodized films in phosperic acid was not similar to that of sulfuric acid, and thin films in the former solution had perpendcular magnetic anisostropy because of large diameter, irregular length and distribution of the pores. It was found that magnetic properties of the thin films, which had doubled layer of two metals, were dominated by the metal electrodeposited on the surface of the anodized oxide films.

  • PDF

Effect of Electrodeposition Condition on GMR Co/Cu Multilayers

  • Rheem, Young-Woo;Yoo, Bong-Young
    • Journal of Magnetics
    • /
    • v.12 no.3
    • /
    • pp.124-128
    • /
    • 2007
  • Co/Cu GMR multilayers were electrodeposited from various electrolytes using the dual bath technique to achieve high sensitive GMR multilayers. GMR ratio and sensitivity were strongly influenced by solution compositions and electrodeposition parameters where GMR and sensitivity of 12% and 0.052%/Oe were achieved from pyrophosphate baths. The effect of plating conditions on properties of Co/Cu multilayers may be attributed to crystallinity and grain size of deposits, and the ability of plating solutions to deposit contiguous films at lower nano thicknesses.

Preparation and Characterization of Ordered Nanostructured Cobalt Films via Lyotropic Liquid Crystal Templated Electrodeposition Method

  • Al-Bishri, Hassan M.;El-Hallag, Ibrahim S.;El-Mossalamy, Elsayed H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3730-3734
    • /
    • 2010
  • A simple, inexpensive and less time consuming electrochemical methods were carried out to prepare ordered mesoporous cobalt films. Ordered mesoporous cobalt films were successfully synthesized by templated electrodepostion of hexagonal $H_1$-e Co ion. The electrodeposited mesopores films were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), low angle X-ray diffraction (XRD) and voltammetric methods. The applicability of thin films as high - performance super capacitors electrode materials is demonstrated electrochemically using cyclic voltammetry (CV) technique.

Carbon Corrosion at Pt/C Interface in Proton Exchange Membrane Fuel Cell Environment

  • Choi, Min-Ho;Beom, Won-Jin;Park, Chan-Jin
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.281-288
    • /
    • 2010
  • This study examined the carbon corrosion at Pt/C interface in proton exchange membrane fuel cell environment. The Pt nano particles were electrodeposited on carbon substrate, and then the corrosion behavior of the carbon electrode was examined. The carbon electrodes with Pt nano electrodeposits exhibited the higher oxidation rate and lower oxidation overpotential compared with that of the electrode without Pt. This phenomenon was more active at $75^{\circ}C$ than $25^{\circ}C$. In addition, the current transients and the corresponding power spectral density (PSD) of the carbon electrodes with Pt nano electrodeposits were much higher than those of the electrode without Pt. The carbon corrosion at Pt/C interface was highly accelerated by Pt nano electrodeposits. Furthermore, the polarization and power density curves of PEMFC showed degradation in the performance due to a deterioration of cathode catalyst material and Pt dissolution.

Comparison of Electrodeposited Carbon Fibers Reinforce Epoxy Composites Using Monomeric and Polymeric Coupling Agents

  • Park, Joung-Man;Kim, Yeong-Min
    • Macromolecular Research
    • /
    • v.8 no.4
    • /
    • pp.153-164
    • /
    • 2000
  • By electrodeposition (ED) using a monomeric- and two polymeric coupling agents, the interfacial shear strength (IFSS) of carbon fiber/epoxy composites was investigated by fragmentation test. ED results were compared with the dipping and the untreated cases under dry and wet conditions. Multi-fiber composites (MFC) were used for the direct comparison for the untreated and the treated cases. Various treating conditions including time, concentration and temperature were evaluated, respectively. Under dry and wet conditions ED treatment exhibited much higher IFSS improvement compared to the dipping and the untreated cases. Monomeric- and polymeric coupling agents exhibited the comparative IFSS improvement. Adsorption mechanism between coupling agents and carbon fiber was analyzed in terms of the electrolyte molecular interactions during ED process based on to the chain mobility. The microfailure modes occurring from the fiber break, matrix and interlayer cracks were correlated to IFSS.

  • PDF