• 제목/요약/키워드: electrochemical sensor

검색결과 358건 처리시간 0.026초

Relationship between BrACs and BACs of Healthy Koreans for BAIIDs

  • SeungHwan Yi;BeomWoo Nam;Jeong-seok Seo
    • 센서학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2024
  • This study aims to suggest the partition ratio (Q-factor) of healthy Koreans and the comparison results of breath alcohol concentration (BAC) measurements using two methods (photoacoustic and electrochemical methods) for developing breath alcohol ignition interlock devices (BAIIDs). Given the relationship between BACs and BrACs and the Q-factor, the alcohol metabolism of healthy Koreans (96 males and 91 females) is revealed for understanding the digestion of alcohol and surveying the fundamental data of alcohol-related problems, CO2 concentrations vs. alcohol concentrations, and the performance of alcohol sensors in the marketplace. The average Q-factor of healthy Korean males and females are 1,913 (95% confidence interval from 1,889-1,937) and 1,991 (95% confidence interval from 1,945-2,036). Photoacoustic measurements could be applied to predict the BACs of drinkers, which is confirmed by the Bland-Altman plots presented in this study. The biases based on the partition ratios (Q=1,913 and Q=1,991) in the Bland-Altman plots were -0.0004% (95% CI from -0.0011 to +0.0003% for males) and -0.0017% (95% CI from -0.020 to +0.017% for females).

탄소나노섬유의 함량에 따른 CNF/PPy 필름의 전기전도도 및 굽힘센서로 응용 (Variations in Electrical Conductivity of CNF/PPy Films with the Ratio of CNF and Application to a Bending Sensor)

  • 김철;장슈와이;김선명
    • Composites Research
    • /
    • 제23권3호
    • /
    • pp.31-36
    • /
    • 2010
  • 서로 다른 CNF(탄소 나노섬유) 함유량을 가진 신 재료인 CNF/폴리피롤(PPy) 복합재료 필름들이 세계 최초로 화학적 전해 중합법으로 제조 되었다. 기존의 물리적 혼합법으로 제조된 필름과 비교하면 재료의 유연성이 매우 증가하였다. 복합재료와의 비교를 위해서 순수 폴리피롤 필름 역시 전해중합 방법으로 제조되었다. 전자주사현미경(SEM)으로 재료 샘플의 전극면, 용액면, 단면을 각각 촬영하여 그 재료 특성을 분석하였다. 각 복합재료 샘플의 전기전도성은 4점 탐침법으로 측정 되었다. 각 필름의 전도성은 두께가 0.013cm인 순수 PPy 필름은 79.33S/cm, 두께가 0.018cm이고 CNF 함유량 5% CNF/PPy 필름은 93S/cm, 두께가 0.017cm이고 CNF 함유량 10% CNF/PPy 필름은 126S/cm으로 측정되었다. CNF의 함유량이 증가할수록 PPy의 전도성이 크게 증가하는 것으로 확인되었으며, CNF/PPy 복합재료의 좋은 전도성은 소형의 굽힘 작동기로 사용될 수 있는 가능성을 높인다. 이를 입증하기 위해서 공기 중에서 작동 가능한 PPy 굽힘 센서를 설계하여 유한요소법으로 해석하였다.

4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발 (Development of electrochemical biosensor for determination of galactose)

  • 박갑수;조순삼;권덕;이재선;차근식;남학현
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.393-399
    • /
    • 2007
  • 본 연구에서는 갈락토오즈의 현장검사(point-of-care testing, POCT)를 위한 일회용 갈락토오즈 바이오센서 개발에 관해 논하고자 한다. Galactose oxidase(GAO)와 horseradish peroxidase(HRP) 두 효소를 0.05 M phosphate 완충용액에 용해시킨 후 스크린 프린팅(screen printing) 방법으로 제작한 전극위에 고정화하여 센서를 제작하였다. 이렇게 제작된 센서를 이용하여 $100{\mu}L$ 이하의 시료를 이용하여 갈락토오즈를 90초 이내에 측정하였다. 전극에서의 반응을 최적화하기 위하여 GAO 효소가 가장 우수한 활성을 나타내는 pH 7.0 완충용액을 이용하여 GAO와 HRP 효소를 1:1로 고정화하고, 1mM 1,1'-ferrocene-dimethanol 전자전달매개체를 도입하여 센서를 제작하였다. 유리 탄소전극의 경우 100 mV (vs Ag/AgCl), 스크린 프린트된 전극의 경우 -100 mV(vs Ag/AgCl)의 인가전압을 적용하였다. 본 연구에 의해 개발된 센서는 $0{\sim}400{\mu}M$의 갈락토오즈 농도에 대하여 우수한 직선성($r^2$ = 0.997, S/N = 3)을 나타내었고 낮은 인가전압을 적용하여 갈락토오즈를 측정하므로, ascorbic acid, uric acid 그리고 acetaminophen과 같은 방해물질의 영향을 최소화 할 수 있었다. 또한 갈락토오즈 표준 용액에 대하여 만족할 만한 재현성을 나타내었다(CV = 5%).

EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링 (Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS))

  • 우성엽;김제경;이정재;기성훈
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.651-662
    • /
    • 2022
  • 이 연구에서는 전기화학적 임피던스분광법(Electrochemical Impedance Spectroscopy, EIS)을 활용하여 콘크리트 속 철근 부식의 개시, 전파 및 이로 인한 콘크리트의 손상을 관찰하기 위한 실험을 수행하였다. 먼저, 직경 25mm, 높이 70mm 원주형 콘크리트 실험체 중심에 지름 5mm의 탄소강봉을 매입한 실험체를 제작하였다. 실험체에 사용된 콘크리트는 물-시멘트 비 0.4, 0.5, 0.6을 갖는 세 가지 배합을 제작하였다. 촉진부식시험을 수행하여 위하여 철근 콘크리트 실험체는 0.5M NaCl 수용액에 침지한 후 0C, 13C, 65C, 130C의 네 가지 수준의 전하량을 인가하였다. 이 연구에서는 부식촉진 및 이 과정에서 EIS의 주기적 모니터링을 자동화하여 실험의 효율을 향상시켰다. 이 연구의 실험 결과를 통하여 EIS 주요 특성인자를 활용하여 콘크리트 속 철근의 부식상태를 효과적으로 평가할 수 있음을 확인하였다. 전하이동저항(Rc)값은 전하인가량이 0C에서 13C로 증가함에 따라 급격히 감소하여 대략 10kΩcm2 값을 나타내었다. 하지만 부식개시 이후 전하인가량을 13C에서 130C로 증가하였을 때 Rc값의 민감도는 현저히 감소하는 것을 확인하였다. 한편 이중층용량값(Cdl)값은 전하인가량이 0C에서 130C로 증가함에 따라 대략 50×10-6μF/cm2 에서 250×10-6μF/cm2 수준으로 선형비례관계를 보였다. 이러한 결과는 Cdl 모니터링을 통하여 부식물질에 팽창에 따라 유발된 콘크리트 내부 손상의 진전을 효과적으로 평가할 수 있음을 보여준다. 이 연구의 결과는 EIS를 활용하여 콘크리트 속 철근 부식의 확산 및 이에 따른 콘크리트 손상의 실시간 모니터링을 위한 매입형 센서 및 EIS 신호 분석방법의 고도화를 위한 기본 데이터를 제공하는데 의미가 있다.

바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발 (Development of PC-based and portable high speed impedance analyzer for biosensor)

  • 김기련;김광년;허승덕;이승훈;최병철;김철한;전계록;정동근
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.

전고체형 에너지 저장 매체 제조를 위한 이온성 액체 기반의 고체 전해질과 탄소나노복합체 기반의 전극소재 개발 (Development of ionic liquid based solid state electrolyte and nanocarbon composite for all solid-state energy storage device)

  • 김용렬;강혜주;정현택
    • 한국응용과학기술학회지
    • /
    • 제36권4호
    • /
    • pp.1253-1258
    • /
    • 2019
  • 고분자를 기반으로 하는 고체 전해질은 수퍼커패시터, 배터리, 센서, 액추에이터 등 다양한 전기화학 소자에 응용이 가능한 소재로써, 기존 고분자 전해질의 낮은 이온전도도를 향상시키기 위해서 다양한 이온성 액체 기반의 고체 전해질에 관한 연구가 활발히 진행 중에 있다. 이온성 액체의 높은 전기적 특성 및 전기화학적, 열적 안정성과 고분자의 우수한 기계적인 강도를 활용한 젤 상태의 고체 전해질인 이온젤은 차세대 웨어러블 및 플렉시블 전자소자에 응용되어 연구되고 있다. 따라서 본 연구에서는 이러한 이온성 액체와 고분자 기반의 고체 전해질을 제조하고 특성을 분석하여 탄소나노복합체 기반의 전극에 적용하여 다양한 전자소자에 응용이 가능한 이온전도도 및 안정성이 향상된 이온성 액체 기반의 고체 전해질을 개발하고자 한다. 제조된 고체전해질은 전기화학적 임피던스법을 이용하여 이온 전도도를 측정하여 보았으며 이온성 액체를 첨가하여 제조한 고체전해질의 이온 전도도가 1.26 × 10-1 S/cm 로 확인되었다. 또한 제조된 고체 전해질을 이용하여 전고체형 수퍼커패시터를 제조하여 전기화학적 특성을 비교하여 보았으며, 수퍼커패시터의 전기화학적 특성 역시 이온성 액체를 첨가하여 제조된 고체 전해질을 사용하였을 때 향상된 전기화학적 특성을 나타내었다.

물/1,2-Dichloroethane 계면에서 Cefotiam 약물 이온의 전이 반응 연구 및 약물 센서에 응용 (Electrochemical Study on Transfer Reaction of Ionizable Cefotiam across a Water/1,2-dichloroethane Interface and Drug Sensing Applications)

  • 리우샤오원;신타제시카;이혜진
    • 공업화학
    • /
    • 제29권5호
    • /
    • pp.581-588
    • /
    • 2018
  • 본 논문은 편극화된 물/1,2-dichloroethane (1,2-DCE) 계면에서 세포티암(cefotiam, CTM) 항생제 약물의 전이 반응을 전기화학적 방법으로 조사하였다. CTM 약물은 물의 pH에 따라 서로 다른 전하를 가지고 이온화되며 각 pH에서 이들 이온의 전이 반응을 연구함으로써 처음으로 CTM 약물이 좀 더 우세하게 물 또는 유기층에 분배되는 정도를 나타내는 상 분배 도표를 세웠다. 이를 바탕으로 CTM 약물의 형식 전이 전위값 및 형식 Gibbs 전이 에너지 값을 포함한 열역학적 정보와 함께 분배 계수를 포함한 중요한 약물동태학 정보를 얻었다. 특히 pH 3.0 수용액에서 양전하를 띠는 CTM 이온의 전이 반응을 순환전압전류법으로 조사한 결과 CTM 농도에 따라 측정한 전류 값이 비례하여 증가한다는 점을 확인하였다. 이를 바탕으로 CTM 이온을 정량 분석 가능한 센서를 개발하였다. 휴대성과 이동성을 보완하기 위해 polyethylene terephthalate 필름에 마이크로홀을 만들어 지지체로 사용하고, 1,2-DCE 유기용매를 polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) 유기성 젤로 대체하여 도포하는 방식으로 센서를 제작하였다. 상기 센서를 이용하여 CTM 약물을 $1{\mu}M$에서 $10{\mu}M$까지 정량 분석할 수 있었다.

Thermal Evaporation법에 의해 제조된 WO3 박막과 NiO-WO3박막의 전기적 특성에 관한 연구 (A Study On the Electrical Characteristic of WO3 and NiO-WO3 Thin Films Prepared by Thermal Evaporation)

  • 나은영;나동명;박진성
    • 전기화학회지
    • /
    • 제8권1호
    • /
    • pp.32-36
    • /
    • 2005
  • 본 연구는 $WO_3$ 박막과 $NiO-WO_3$ 박막을 고진공 저항가열식 thermal evaporation 법으로 (100) n형의 실리콘 단결정 기판 위에 증착시켰고, 막의 결정성 증진을 위하여 공기 중 $500^{\circ}C$에서 30분 동안 열처리하였다. 박막의 결정성 및 결정구조를 분석하기 위해서 X선 회절분석기를 사용하였고, 표면 및 단면 관찰을 위해서는 주사전자현미경을 이용하였다. 그리고 화학 조성 결합에너지는 XPS를 이용하였다. 순수 $WO_3$ 박막의 결정 크기는 $500^{\circ}C$에서 30분 동안 공기중 열처리에 의해서 $0.6{\mu}m$로 성장하였고 $WO_3$ 박막의 두께가 증가할수록 거의 변화 없이 일정하였다. 반면, NiO가 첨가된 $WO_3$ 박막 두께별 결정크기는 각각 $0.12{\mu}m,\;0.28{\mu}m,\;0.32{\mu}m$$0.43{\mu}m$로 순수 $WO_3$ 박막에 비해 치밀한 표면을 형성하였고, 최대 5배정도 성장이 억제되었다. 가스감도 측정은 대기 중에서의 센서 저항 값을 기준으로 측정가스 저항 값의 비율 $(R_{NOx}/R_{air})$로 가스감도를 나타내었다. 전기적 성질은 MFC로 NOx가스 5ppm을 일정히 유지시켰고, Multimeter로 계측하여 컴퓨터에 자동 계측되는 시스템을 사용하였다. 순수 $WO_3$박막보다는 $NiO-WO_3$ 박막이 우수한 NOx 감도특성을 보였고 센서의 작동온도는 $250^{\circ}C$에서 우수한 감도를 나타내었다.

다공질 실리콘: 새로운 마이크로센서 및 마이크로액추에이터 재료 (Porous silicon : a new material for microsensors and microactuators)

  • 민남기;이치우;정우식;김동일
    • 전기화학회지
    • /
    • 제2권1호
    • /
    • pp.17-22
    • /
    • 1999
  • 다공질 실리콘을 이용한 마이크로센서와 마이크로액츄에이터의 연구는 현재 초기단계에 있기 때문에, 지금까지 발광 다이오드나 화학 센서 등과 같은 몇몇 응용 소자가 발표된 수준에 머물러 있다. 본 논문에서는 화학 센서와 광소자를 중심으로 다공질 실리콘 센서 및 액추에이터 연구현황을 고찰 보고하고자 한다. 정전용량형 다공질 실리콘 습도센서의 감습 특성은 비선형이였으며, 저습보다는 $40\%RH$ 이상의 고습영역에서 더 높은 감도를 나타내었다. 다공질 실리콘 $n^+-p-n^+$ 소자는 에탄올에 노출되었을 때 소자 전류가 급격히 증가하였다. 다공질 실리콘 다이어프램에 제작된 $p^+-PSi-n^+$ 다이오드는 광 스위칭 현상을 나타내어 광센서 또는 광스위치로써의 응용 가능성을 보여주었다. 다공질 실리콘에 365nm를 조사해서 얻어진 광루미네센스(PL)는 넓은 스펙트럼을 보였으며, 피크 파장은 610 nm이었다. ITO/PSi/In LED의 전계발광(EL)스펙트럼은 PL에 비해 약간 더 넓은 영역에 걸쳐 나타났으며, 피크 에너지가 단파장(535nm)으로 이동하였다.

전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서 (Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F)

  • 지성은;이상혁;이혜진
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.258-263
    • /
    • 2023
  • 본 연구에서는 일회용 센서 칩으로 제작 가능한 스크린 프린팅된 탄소칩 전극(screen printed carbon electrode; SPCE) 표면에 전도성고분자 및 효소 티로시나아제(tyrosinase, Tyr)를 적층하여 전기화학적인 방법으로 남성 질환, 갑상선 질환 등과 연관성이 입증된 내분비계 교란 물질인 비스페놀F (bisphenol F, BPF) 검출에 적용하였다. 산소 플라즈마 처리를 통해 음전하를 띠게 한 SPCE 작업전극 표면에 양전하를 띄는 전도성 고분자인 poly(diallyldimethyl ammonium chloride) (PDDA)과 음전하를 띠는 고분자 화합물 poly(sodium 4-styrenesulfonate) (PSS) 그리고 PDDA 순서대로 정전기적인 인력으로 층을 쌓고, 최종적으로 pH (7.0)를 조절하여 음전하를 띄게 한 효소, Tyr층을 올려 PDDA-PSS-PDDA-Tyr 센서를 제작하였다. 상기 전극 센서를 기질이자 타겟분석물인 BPF 용액에 접촉하면, 전극 표면에서 Tyr 효소와 산화반응에 의해 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione)가 생성되고, 순환전압전류법과 시차펄스전압전류법을 이용하여 생성물을 0.1 V (vs. Ag/AgCl)에서 환원하면 4,4'-methylenebis(benzene-1,2-diol)이 생성되면서 발생하는 피크 전류 값의 변화를 측정함으로써, BPF의 농도를 정량적으로 분석하였다. 또한, 기존에 많은 연구에서 사용되는 인산완충생리식염수를 대체할 수 있는 이온성 액체 전해질을 사용하여 BPF의 검출 성능 결과를 비교하였다. 또한 BPF와 유사한 구조를 갖는 방해물질로 작용하는 비스페놀S에 대한 선택성을 확인하였다. 마지막으로 실험실에서 준비한 실제 시료안의 BPF의 농도를 분석하는데 제작한 센서를 적용함으로써 센서의 실제 적용 가능성을 입증하고자 하였다.