• Title/Summary/Keyword: electrochemical detector

Search Result 46, Processing Time 0.019 seconds

Electrochemical Properties of Self-Assembled Viologen Monolayers Using Quartz Crystal Analyzer (QCA를 이용한 자기조립된 Viologen 단분자막의 전기화학적 특성)

  • Lee, Dong-Yun;Park, Sang-Hyun;Shin, Hoon-Kyu;Park, Jae-Chul;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.141-144
    • /
    • 2004
  • Molecular self-assembled of surfactant viologens are recently interesting because they can be from functional electrodes as well as micelle assemblies which can be profitably utilized for display devices, electrochemical studies and electrocatalysis as electron acceptor or electron mediator. The electrochemical behavior of self-assembled viologen monolayer on Au electrode surface has been investigated with QCM which has been known as nano-gram order mass detector. A monolayer of viologen is immobilized on the gold electrode surface and the normal potentials corresponding to the to the successive one-electron transfer processes of the viologen actives are two peaks in 0.1mol/l phosphate buffer solution respectively. These result suggest that the viologen SAMs are stable and well-behaved monolayers.

  • PDF

DNA Ligand - Redox Active Molecule Conjugates as an Electrochemical DNA Probe

  • Ihara, Toshihiro;Maruo, Voshiyuki;Uto, Yoshihiro;Takenaka, Shigeori;Takagi, Makoto
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.887-894
    • /
    • 1995
  • Toward the development of universal, sensitive, and convenient method of DNA (or RNA) detection, two kinds of electrochemically active DNA ligands. acridine - viologen and oligonucleotide - ferrocene conjugate, were prepared. Thermodynamic and electrochemical study revealed that these probes bound strongly to DNA, and showed a typical cyclic voltammograms, indicating a potential for use as a reversible electrochemical labelling agent for DNA. Especially, using the electrochemically active oligonucleotide, we have been able to demonstrate the detection of DNA at femtomole levels by HPLC equipped with ordinary electrochemical detector (ECD). These results lead to the conclusion that the redox-active probes are very useful for the microanalysis of nucleic acid due to the stabilily of the complexes, high detection sensitivity, and wide applicability to the target structures (single- and double strands) and sequences.

  • PDF

A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction (광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구)

  • Dai Woon Lee;Young Hun Park;Yong Wook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.4
    • /
    • pp.453-461
    • /
    • 1993
  • Detection method was developed using a simply designed photochemical reactor made of teflon coil and low pressure mercury lamp. This method of UV photolysis of analytes followed by UV, fluorescence and electrochemical detection was found to be useful for four thiocarbamates. Analytes eluting from the column are irradiated with a high flux of 254 nm UV light, so that they change to either fluorescent active forms or highly electrochemically sensitive products. Appling this technique to the UV detection, thiocarbamates were converted into long wavelength absorbing products upon UV irradiation. In fluorescence detector four thiocarbamates are not detected at nonirradiated condition but fluorescence signals of MPTC, CPTC photolysates are appeared after irradiation with UV light. The electrochemical detection for the determination of thiocarbamates was enhanced up to 5∼20 fold signal after UV irradiation, compared to that of the nonirradiated. The detection limit of thiocarbamates on electrochemical detector was 13.3∼0.02 ng under pH 7.0, ionic strength $0.5{\times}10^{-2}$ M, phosphate buffer solution. Adducts produced by reaction of photolysates and OPA-MERC in the reaction coil were monitored at 425 nm with fluorescence detector, and one of the photolysates was primary amine.

  • PDF

Conceptual design of neutron measurement system for input accountancy in pyroprocessing

  • Lee, Chaehun;Seo, Hee;Menlove, Spencer H.;Menlove, Howard O.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1022-1028
    • /
    • 2020
  • One of the possible options for spent-fuel management in Korea is pyroprocessing, which is a process for electrochemical recycling of spent nuclear fuel. Nuclear material accountancy is considered to be a safeguards measure of fundamental importance, for the purposes of which, the amount of nuclear material in the input and output materials should be measured as accurately as possible by means of chemical analysis and/or non-destructive assay. In the present study, a neutron measurement system based on the fast-neutron energy multiplication (FNEM) and passive neutron albedo reactivity (PNAR) techniques was designed for nuclear material accountancy of a spent-fuel assembly (i.e., the input accountancy of a pyroprocessing facility). Various parameters including inter-detector distance, source-to-detector distance, neutron-reflector material, the structure of a cadmium sleeve around the close detectors, and an air cavity in the moderator were investigated by MCNP6 Monte Carlo simulations in order to maximize its performance. Then, the detector responses with the optimized geometry were estimated for the fresh-fuel assemblies with different 235U enrichments and a spent-fuel assembly. It was found that the measurement technique investigated here has the potential to measure changes in neutron multiplication and, in turn, amount of fissile material.

The electrochemical study on Viologen SA monolayer using QCM (수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성)

  • Kim, Jung-Myoung;Yoon, Hee-Chan;Song, Seung-Hun;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.21-23
    • /
    • 2002
  • In this paper, the electrochemical behavior of Viologen self assembly monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self assemvly process of Viologen was monitored using resonant frequency $({\Delta}F)$ and resonant resistance(R). QCM measurements indicated a mass adsorption for Viologen assembling on the gold sufrace with a frequency change about 135[Hz] and calculated its surface coverage($\Gamma$) to be $3.5273{\times}10^{-9}[mol/cm^{2}]$. Also reversible redox process was observed and analyzed with ionic interaction at the Viologen/solution interface using ${\Delta}F$.

  • PDF

An Experimental Study on the Characteristics of NOx Cox Emissions and the Measuring Technique of NOx inMarine diesel Engines (박용 디젤기관의 NOx.COx 배출특성과 NOx 측정법에 관한 실험연구)

  • 최재성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.19-24
    • /
    • 1999
  • In this paper the emission characteristic of the ship's diesel engine with CPP(Controllable Pitch Propeller) were investigated under the passage test on the sea. As the results it is confirmed that the NOx.$CO_x$ concentrations increase as the engine speed increases and the torque decreases. but the amount of NOx, COx emissions(g./k Wh) decrease as the torque increase regardless of the engine speed. Also it is compared with the NOx concentra-tions measured by the two method-ECC(Electrochemical Cell)and CLD(Chemiluminescence Detector)for the correct measurement and the ECC indicated higher value than the CLD.

  • PDF

Electrochemical Properties of Viologen Self-Assembly Monolayer Using QCM (수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성)

  • 옥진영;신훈규;박재철;장정수;권영수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.496-500
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface[1]. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency(ΔF) and resonant resistance(R). The redox process of viologen was observed with resonant frequency(ΔF).

Study on the Electrochemical Behavior of the Viologen Monolayers by Different Chemical Structure (분자구조에 따른 Viologen 단분자막의 전기화학적 특성 연구)

  • Ock, Jin-Young;Shin, Hoon-Kyu;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.918-921
    • /
    • 2003
  • The electrochemical behavior of vilogen self-assembled monolayer has been investigated with QCM, which has been known as ng order mass detector. The self-assembly process of viologen was monitored using resonant frequency(${\Delta}F$) and resonant resistance(R). The QCM measurements indicated a mass adsorption for viologen assembling on the gold surface with a frequency change about 300, 135 Hz and calculated its surface coverage($\Gamma$) to be $5.02{\times}10^{-9}$ and $1.64{\times}10^{-9}mol/cm^2$. Also a reversible redox process was observed and analyzed with an ionic interaction at the Viologen/solution interface using ${\Delta}F$.

  • PDF

크롬친화세포의 배양방법

  • 임동윤;고석태
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.150-150
    • /
    • 1993
  • 목적 :크롬친화세포는 카테콜아민 (CA)을 분비하는 새포로서 무신 수질내에 주로 존재한다. 따라서 부신피질의 영향을 배제하여 여러가지 자율신경계 작용 약물의 약리작용을 연구하는데 중요한 조직이다. 그러므로, 부신으로부터 크롬친화세포를 분리하여 배양하는 방법을 습득하여 자율신경계 작용약물연구에 이용코자 히스타민을 이용하여 CA 분비작용을 연구하였다. 방법: 도살장에서 소를 즉사시킨 후 좌우양측 부신을 분리하여 collagenase digestion으로 부신수질로부터 분리하고 Percoll gradient에 의해서 chromaffine cell을 정제하였다. 이렇게 정제한 크롬친화세포는 Dulbecco's modified Eagle medium에 10% fetal calf serum과 함께 culture dish에다 넣어 5% $CO_2$, incubator에서 유지시켜 주면서 실험을 시행하였다. 배양세포는 분리후 일주일 이내에 사용하였다. Catecholamine측정은 electrochemical detector를 연결하여 HPLC로 측정하였다.

  • PDF

Electrochemical Properties of Viologen Self-Assembly Monolayer Using QCM (수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성)

  • Ock, J.Y.;Song, S.H.;Shin, H.K.;Park, J.C.;Chang, J.S.;Chang, S.M.;Kwon, Y.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.403-406
    • /
    • 2002
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electroeds as well as micellar assemblies. which can be profitably utilized for display devices. photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator[1-3]. Fromherz et al studied the se1f-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface[4]. In this study, the electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency$({\Delta}F)$ and resonant resistance(R). The redox process of viologen was observed with resonant frequency$({\Delta}F)$.

  • PDF