• 제목/요약/키워드: electrochemical detector

검색결과 46건 처리시간 0.022초

요중 알파나프틸아민 분석에 관한 연구 (The study on the analysis of α-naphthylamine in urine)

  • 김춘성;노재훈;배문주;김치년;임남구;원종욱
    • 한국산업보건학회지
    • /
    • 제7권1호
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

Study on the Output Current for Electrochemical Low-energy Neutrino Detector with Regards to Oxygen Concentration

  • Suda, Shoya;Ishibashi, Kenji;Riyana, Eka Sapta;Aida, Yani Nur;Nakamura, Shohei;Imahayashi, Yoichi
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.373-377
    • /
    • 2016
  • Background: Experiments with small electrochemical apparatus were previously carried out for detecting low-energy neutrinos under irradiation of reactor neutrinos and under natural neutrino environment. The experimental result indicated that the output current of reactor-neutrino irradiated detector was appreciably larger than that of natural environmental one. Usual interaction cross-sections of neutrinos are quite small, so that they do not explain the experimental result at all. Materials and Methods: To understand the experimental data, we propose that some biological products may generate AV-type scalar field B0, leading to a large interaction cross-section. The output current generation is ascribed to an electrochemical process that may be assisted by weak interaction phenomena. Dissolved oxygen concentrations in the detector solution were measured in this study, for the purpose of understanding the mechanism of the detector output current generation. Results and Discussion: It was found that the time evolution of experimental output current was mostly reproduced in simulation calculation on the basis of the measured dissolved oxygen concentration. Conclusion: We mostly explained the variation of experimental data by using the electrochemical half-cell analysis model based on the DO concentration that is consistent to the experiment.

Real Time Spectroelectrochemical Experiments with a Multichannel Detector

  • Sun-Il Mho;Sally N. Holer;Bum-Soo Kim;Su-Moon Park
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.739-743
    • /
    • 1994
  • A spectroelectrochemical system assembled with a white light source, bifurcated optical fiber, Oriel Multispec spectrograph, and a charge-coupled device (CCD) detector is described. The system is shown to be capable of acquiring a whole spectrum in the spectral range of 290-800 nm in 25 ms or a longer period during electrochemical experiments at reflective working electrodes such as platinum or mercury. The utility of the system in studying electrochemical reactions during the potential scan, galvanostatic electrolysis, or after the potential step is demonstrated.

Electrochemical Parameters with unusual Alternating Current Phase-Angles

  • Rashwan Farouk;Mohran Hossnia
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.80-82
    • /
    • 2004
  • The a.c. technique is employed to evaluate electrochemical characteristics of Naphthalie-1,4,5,8-tetracarboxylic acid bisanilide (NTB). The measurements were carried out in dry and pure propionitrle (PCN) and acetonitrile(CAN) at the hanging mercury drop electrode [HMDE). An A.C. phase sensitive detector using computer controlled lock-in amplifier was employed. Primary goal of this report, was to establish on a firm the rare behavior of the phase angle associated with a.c. polarograms of the compound. Although, not an initial goal of this study, the electron transfer rate parameters attending the electroreduction of the compound under investigation were determined. This because the results shed some light on the electrokinetics in aprotic solvent which until recently negligible data were available. Experimental Results and comparison of data obtained are reported. The good precision of the method makes it suitable for studying electrochemical data with unusual behavior at electrodes in non aqueous media.

식품중 Aflatoxin 측정방법의 비교 (Comparison of methods for Determination of Aflatoxins in food Products)

  • 김면희
    • 한국식품위생안전성학회지
    • /
    • 제11권2호
    • /
    • pp.149-157
    • /
    • 1996
  • A procedure for the determination of Aflatoxins in food and grains which utilizes reversed phased liquid chromatographic (LC) analysis with postcolumn derivatization by an electrochemical cell and determination with a fluorescence detector has been evaluated. The LC mobile phase was water-acetonitrile-methanol (6+2+2) with 1mM KBr and 1 mM HNO3 which gave baseline separation for the four Aflatoxins (AfB1, AfB2, AfG1, AfG2). The electrochemical cell set at 7V, generated bromine and derivatized aflatoxins B1 and G1, The derivatives were detected by the fluorescence detector. The aflatoxins in naturally contaminated corn samples were isolated by three different cleanup procedures: the AOAC method I column(CB method), a rapid filtrate column (Romer's column), and an immunoaffinity column. The final extract were quantitated with fluordensitometric TLC and the LC postcolumn derivatization techniques. The results were quite similar, however the LC technique showed less interferences and could be automated. Samples of corn, raw peanuts, peanut butter and dried dates were also analyzed successfully with this procedure.

  • PDF

Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기 (An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode)

  • 이인제;김주호;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

HPLC-ECD에 의한 흰쥐 뇌 부위별 Catecholamine 및 대사산물의 신속정량법 (Determination of Catecholamines and Their Metabolites in Rat Brain by High Performance Liquid Chromatography with Electrochemical Detector)

  • 노일협
    • 약학회지
    • /
    • 제32권1호
    • /
    • pp.50-54
    • /
    • 1988
  • A simple and sensitive method was studied for the simultaneous determination of catecholamine, indoleamine and their related metabolites by high performance liquid chromatography with electrochemical detector. Norepinephrine, dopamine, serotonin and their metabolites of 3,4-dihydroxyphenylacetic acid, homovanillic acid, 5-indoleacetic acid were resolved from rat brain tissue homogenates by separation on reversed phase $C_{18}$ column with mobile phase consisting of monochloroacetate buffer (pH2.47), 1.42mM sodium octyl sulfonate and 7% acetonitrile. Both catechols and indoles can be eluted in 15min. The sensitivities of this method are sufficient for determination of at least 100 pg of neurochemical amines in brain samples, for example, frontal cortex, olfactory bulb, striatum, septum, hippocampus, thalamus, hypothalamus, medulla & pons and cerebellum. The highest level of dopamine was observed in striatum whereas norepinephrine and serotonin were in hypothalamus.

  • PDF

사람혈장중 S-2-(3-Aminopropylamino) ethylphosphorothioate 및 S-2-(3-Methylaminopropylamino) ethylphosphorothioate의 수은/금 전기화학검출기를 이용한 고속액체크로마토 그라프법에 의한 분석 (An Improved HPLC Assay Using Hg/Au Electrochemical Detector for S-2-(3-aminopropylamino) ethylphosphorothioate and S-2-(3-methylaminopropylamino) ethylphosphorothioate in Human Plasma)

  • 한건
    • Journal of Pharmaceutical Investigation
    • /
    • 제17권2호
    • /
    • pp.55-60
    • /
    • 1987
  • WR 2721 (S-2-(3-aminopropylaminoethylphosphorothioate) is a radioprotective drug that is now undergoing clinical trials in the United States and Japan. a liquid chromatographic electrochemical method for the determination of WR 2721 an WR 3689 [S-2-(3-methylaminopropylamino)ethylphorothioate] in human plasma was developed in this study. This method includes the use of a Hg/Au electrochemical detector and a cyano column for the direct measurement of WR 2721 and WR 3689 in plasma. An analog of WR 2721, WR 149846 was used as an internal standard. WR 2721 and WR 3689 could be well separated from the solvent front, with a mobile phase of acetonitrile-water (20:80), 0.1M acetic acid and 1.2 mM sodium octane sulfonate. This method was shown to be precise. Both intra-day and inter-day results were within 10% CV. Also, sample preparation was fairly simple. Since WR 2721 and WR 3689 were unstable at room temperature, it was essential to use an automatic sample processor with a refrigerator, especially for carrying out routine analyses.

  • PDF

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

환경수질오염 검증과 전기화학실험을 위한 양극펄스형 전기전도성검출기의 개발 (Development of a Bipolar Pulse Conductometric Detector for Environmental Monitoring and Electrochemical Experiments)

  • 김해동;김선태;김택제;김영상
    • 분석과학
    • /
    • 제5권1호
    • /
    • pp.79-82
    • /
    • 1992
  • 연속적으로 흐르는 시료의 검출을 위한 양극펄스형 전기전도성 검출기를 개발하였다. 개발한 전기전도성 검출기는 동작이 매우 빠를 뿐더러 직렬 혹은 병렬축전 방해효과가 없으므로 사용이 쉽다. 개발한 양극펄스형 전기전도성 검출기의 성능을 $10^1{\sim}10^8$저항을 가진 가상 셀들을 사용하여 시험한 결과 0.01% 상대편차를 보이는 직선성 응답을 얻을 수 있었다. 개발한 전기 전도성 검출기의 장단점과 여러 가능한 응용들에 대해서도 검토하였다.

  • PDF