• Title/Summary/Keyword: electrochemical coating

Search Result 485, Processing Time 0.024 seconds

Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials (TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성)

  • Kim, Y.U.;Cho, J.Y.;Choe, H.C.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

Progress in Composite Polymer Membrane for Application as Separator in Lithium Ion Battery (리튬 이온 전지의 분리막으로 사용하기 위한 복합 고분자 막의 동향)

  • Oh, Seok Hyeon;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.228-241
    • /
    • 2020
  • Separators, which produces physical layer between a cathode and anode, are getting enormous attention as the quality of the separator determines the performance of lithium ion batteries (LIBs). Porous membranes based on polyethylene (PE) and polypropylene (PP) are generally utilized as the separator of LIBs because of their high electrochemical stability and suitable mechanical strength. However, low thermal resistance and wettability of PE and PP membranes limited the potential of LIBs. Operating at the temperature exceeding the melting point of membranes, the separators change their structures which lead to short circuit of LIBs. Low wettability of the separators corresponds to low ionic conductivity which increases the cell resistance. To overcome these weaknesses of PE and PP separators, different types of separator were prepared by co-electrospinning, applying coating layer, forming core shell around membrane, and papermaking method. The synthesized separator greatly enhanced the heat resistance and wettability of separator and mechanical properties like flexibility and tensile strength. In this review different type of polymer membrane used as separator in lithium ion battery are discussed.

Electrochemical Properties of Pyrrole/Thiophene Polymer Composite (피롤/티오펜 고분자 복합체의 전기화학적 성질)

  • Cha, Seong Keuck;Choi, Kyu Seong;Ahn, Byuong Kee;Kang, Sang Jin
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.7
    • /
    • pp.467-473
    • /
    • 1996
  • Although a polypyrrole shows better electrical conductivity, 100∼400 ${\Omega}^{-1}cm^{-1}$, than other organic conducting polymers, its electrical conductivity will be worsen in the presence of the oxygen due to its easy oxidation. On the other hand, polythiophene shows better stability in the air while its electrcal conductivity is poor compared to the polypyrrole. We succeed to develope the mixed polymer electrode that is stable in the air and shows a good redox characteristics. The mixed polymer electrode has been prepared by the electrical polymerization of polypyrrole on the Pt electrode as 1.70 C$cm^{-2}$ and then coating with polythiophene as 0.34 C$cm^{-2}$. The polymerization rate of polythiophene was $3.89{\times}10^{-8}$ at the bare Pt electrode and $6.07{\times}10^{-8}cms^{-1}$ at the mixed polymer electrode. And the standard rate constants of each electrode were $5.16{\times}10^{-6}\;and\;3.94{\times}10^{-4} cms^{-1}$ respectively. Also, the electrocatalytic rate of the polypyrrole polymer electrode was $3.45{\times}10^{-3}cm^3mol^{-1}s^{-1}.$ We found the immobilized layer at the modified electrode acted as an electrocatalyst. Finally, this polymerization process at the Pt electrode was the electron transfer controlled, but that the mixed polymer electrode was the diffusion and charge transfer controlled.

  • PDF

EFFECTS OF DIFFERENT OXIDIZED SURFACES OF IMPLANT ON OSSEOINTEGRATION; RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS STUDY IN MINI-PIGS (다양한 양극산화막 처리방법이 임플란트 골유착에 미치는 영향)

  • Kwon, Kyung-Hwan;Min, Seung-Ki;Sung, Dae-Hyuk;Choi, Jae-Young;Choi, Seung-Lim;Cha, Su-Ryeon;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.5
    • /
    • pp.383-393
    • /
    • 2007
  • The aim of the present study is to investigate the effect of anodized surface of osseointegration implants by using of resonance frequency analysis (RFA) and histomorphometric analysis. A total of 96 screw-shaped implants were devided into 4 groups. Seventy-two implants were prepared by electrochemical oxidation with 3 different ways; Group 1 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid, Group 2 (n=24) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate, and Group 3 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by Calcium metaphosphate(CMP) coating. Control group (n=24) were the RBM surfaced implants. The implants were placed in the mandibles of 12 mini pigs. Bone tissue responses were evaluated by resonance frequency analysis(RFA) and histomorphometric analysis that were undertaken at 2, 4 and 6weeks after implant placement. The following result were obtained. 1. Twenty-two of 96 implants (4 in control group, 5 in group 1, 7 in group 2, and 6 in group 3) were failed due to faliure of osseoitegration. The failure rate of osseointegration was 22.9%. 2. The mean values of RFA in control, group 2 and groups 3 showed the similar values, but there was no significant difference among groups. 3. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact ratio in group 2 at 3 and 4 weeks after implant placement than other groups (p<0.05), but there was no significant difference among groups at 6weeks after implant placement.

Corrosion Behaviors of TiN Coated Dental Casting Alloys (TiN피막 코팅된 치과주조용 합금의 부식거동)

  • Jo, Ho-Hyeong;Park, Geun-Hyeng;Kim, Won-Gi;Choe, Han-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.129-137
    • /
    • 2009
  • Corrosion behaviors of TiN coated dental casting alloys have been researched by using various electrochemical methods. Three casting alloys (Alloy 1: 63Co-27Cr-5.5Mo, Alloy 2: 63Ni-16Cr-5Mo, Alloy 3: 63Co-30Cr-5Mo) were prepared for fabricating partial denture frameworks with various casting methods; centrifugal casting(CF), high frequency induction casting(HFI) and vacuum pressure casting(VP). The specimens were coated with TiN film by RF-magnetron sputtering method. The corrosion behaviors were investigated using potentiostat (EG&G Co, 263A. USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion morphologies were analyzed using FE-SEM and EDX. Alloy 1 and Alloy 2 showed the ${\alpha}-Co$ and ${\varepsilon}-Co$ phase on the matrix, and it was disappeared in case of TiN coated Alloy 1 and 2. In the Alloy 3, $Ni_2Cr$ second phases were appeared at matrix. Corrosion potentials of TiN coated alloy were higher than that of non-coated alloy, but current density at passive region of TiN coated alloy was lower than that of non-coated alloy. Pitting corrosion resistances were increased in the order of centrifugal casting, high frequency induction casting and vacuum pressure casting method from cyclic potentiodynamic polarization test.