• 제목/요약/키워드: electrochemical activation

검색결과 228건 처리시간 0.027초

보철용 지르코니아 어버트먼트의 표면적합도와 전기화학적 거동 (Surface Compatibility and Electrochemical Behaviors of Zirconia Abutment for Prosthodontics)

  • 박근형;정용훈;김원기;최한철;김명수
    • 한국표면공학회지
    • /
    • 제42권1호
    • /
    • pp.41-46
    • /
    • 2009
  • The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at $1500^{\circ}F$ for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was $5{\sim}12{\mu}m$ for small gap, and $40{\sim}60{\mu}m$ for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/fixture was .290 mV and metal abutment/fixture was .280 mV, whereas $|E_{pit}-E_{corr}|$ of zirconia abutment/fixture (172 mV) was higher than that of metal abutment/fixture (150 mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

골아세포가 배양된 치과 임플란트용 Ti-Ta합금의 전기화학적 특성 (Electrochemical Characteristics of Osteoblast Cultured Ti-Ta Alloy for Dental Implant)

  • 김원기;최한철;고영무
    • 한국표면공학회지
    • /
    • 제41권2호
    • /
    • pp.69-75
    • /
    • 2008
  • Electrochemical behaviors of surface modified and MC3T3-E1 cell cultured Ti-30Ta alloys have been investigated using various electrochemical methods. The Ti alloys containing Ta were melted by using a vacuum furnace and then homogenized for 6 hrs at $1000^{\circ}C$. MC3T3-E1 cell culture was performed with MC3T3-E1 mouse osteoblasts for 2 days. The microstructures and corrosion resistance were measured using FE-SEM, XRD, EIS and potentiodynamic test in artificial saliva solution at $36.5{\pm}1^{\circ}C$. Ti-Ta alloy showed the martensite structure of ${\alpha}+{\beta}$ phase and micro-structure was changed from lamellar structure to needle-like structure as Ta content increased. Corrosion resistance increased as Ta content increased. Corrosion resistance of cell cultured Ti-Ta alloy increased predominantly in compared with non cell cultured Ti- Ta alloy due to inhibition of the dissolution of metal ion by covered cell. $R_p$ value of MC3T3-E1 cell cultured Ti-40 Ta alloy showed $1.60{\times}10^6{\Omega}cm^2$ which was higher than those of other Ti alloy. Polarization resistance of cell-cultured Ti-Ta alloy increased in compared with non-cell cultured Ti alloy.

Biocompatibility and Surface Characteristics of PEO-treated Ti-40Ta-xZr Alloys for Dental Implant Materials

  • Yu, Ji-Min;Cho, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.23-23
    • /
    • 2018
  • In this study, new titanium alloys were prepared by adding elements such as tantalum (Ta), zirconium (Zr) and the like to complement the biological, chemical and mechanical properties of titanium alloys. The Ti-40Ta-xZr ternary alloy was formed on the basis of Ti-40Ta alloy with the contents of Zr in the contents of 0, 3, 7 and 15 wt. %. Plasma electrolytic oxidation (PEO), which combines high-voltage sparks and electrochemical oxidation, is a novel method to form ceramic coatings on light metals such as Ti and its alloys. These oxide film produced by the electrochemical surface treatment is a thick and uniform porous form. It is also composed of hydroxyapatite and calcium phosphate-based phases, so it has the characteristics of bone inorganic, non-toxic and very high bioactivity and biocompatibility. Ti-40Ta-xZr alloys were homogenized in an Ar atmosphere at $1050^{\circ}C$ for 1 hour and then quenched in ice water. The electrochemical oxide film was applied by using a power supply of 280 V for 3 minutes in 0.15 M calcium acetate monohydrate ($Ca(CH_3COO)_2{\cdot}H_2O$) and 0.02 M calcium glycerophosphate ($C_3H_7CaO_6P$) electrolyte. A small amount of 0.0075M zinc acetate and magnesium acetate were added to the electrolyte to enhance the bioactivity. The mechanical properties of the coated surface of Ti-40Ta-xZr alloys were evaluated by Vickers hardness, roughness test, and elastic modulus using nano-indentation, and the surface wettability was evaluated by measuring the contact angle of the coated surface. In addition, cell activation and differentiation were examined by cell culture of HEK 293 (Human embryonic kidney 293) cell proliferation. Surface properties of the alloys were analyzed by scanning electron microscopy(FE-SEM), EDS, and X-ray diffraction analysis (XRD).

  • PDF

치아색으로 코팅된 NiTi 와이어의 전기화학적 특성 (Electrochemical Characteristics of Tooth Colored NiTi Wire)

  • 김원기;조주영;최한철;이호종
    • Corrosion Science and Technology
    • /
    • 제9권5호
    • /
    • pp.223-232
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength, friction resistance, and high corrosion resistance. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate electrochemical characteristics of tooth colored NiTi wire using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with optical microscopy (OM), field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The corrosion properties of the specimens were examined using potentiodynamic tests (potential range of -1500 ~ 2000 mV) and electrochemical impedance spectroscopy (frequency range of 100 kHz ~ 10 mHz) in a 0.9 % NaCl solution by potentiostat. From the results of polarization behavior, the passive region of non-coated NiTi wire showed largely, whereas, the passive region of curved NiTi wire showed shortly in anodic polarization curve. In the case of coated NiTi wire, pitting and crevice corrosion occurred severely at interface between non-coated and coated region. From the results of EIS, polarization resistance(Rp) value of non-coated round and rectangular NiTi wire at curved part showed $5.10{\times}10^5{\Omega}cm^2$ and $4.43{\times}10^5{\Omega}cm^2$. lower than that of coated NiTi wire. $R_p$ of coated round and rectangular NiTi wire at curved part showed $1.31{\times}10^6{\Omega}cm^2$ and $1.19{\times}10^6{\Omega}cm^2$.

Fe-V Chloric/Sulfuric Mixed Acid 레독스흐름전지 전극의 활성화 온도에 따른 전기화학적 성능 고찰 (A Study on the Electrochemical Performance of Fe-V Chloric/Sulfuric Mixed Acid Redox Flow Battery Depending on Electrode Activation Temperature)

  • 이한얼;김대업;김철중;김태근
    • 공업화학
    • /
    • 제31권6호
    • /
    • pp.639-645
    • /
    • 2020
  • 레독스흐름전지(redox flow battery, RFB)의 구성 부품 중 전극은 전해액의 확산층 역할을 함과 동시에 전자의 통로 역할을 담당하여 출력에 직접적인 영향을 미치는 주요 부품이다. 본 연구는 Fe2+/Fe3+와 V2+/V3+를 레독스 커플로 사용한 RFB 시스템에 chloric/sulfuric mixed acid 지지 전해액을 사용한 경우 전극 종류 및 활성화 정도에 따른 용량, 쿨롱 효율, 에너지 효율을 비교하여 최적의 전극 및 활성화 정도를 제시하였다. 실험에 사용된 5종의 탄소 전극을 사용한 단일셀 평가에서 모두 이론 용량에 근사한 값을 보여 신뢰성을 확보하였으며, 사용된 전극 중 GFD4EA는 상대적으로 우수한 에너지 효율 및 충방전 용량을 나타내었다. 활성화 온도에 따른 전기화학적 성능 고찰을 위하여 GFD4EA 전극을 공기 분위기 하에서 400, 450, 500, 600 및 700 ℃에서 열처리하여 활성화하였다. 질량 변화, 주사전자현미경(SEM) 및 XPS 분석을 통하여 활성화 전 후의 물성 변화를 관찰하였으며, 각각의 온도에서 활성화된 전극을 적용한 RFB 단일셀 평가를 실시하여 전기화학적 성능을 비교하였다.

전기화학적 정전위 활성화를 사용한 수소 제거에 의한 AlGaN기반의 UV-C 발광 다이오드의 p-형 활성화 (p-Type Activation of AlGaN-based UV-C Light-Emitting Diodes by Hydrogen Removal using Electrochemical Potentiostatic Activation)

  • 이고은;최낙준;찬드라 모한 마노즈 쿠마르;강현웅;조제희;이준기
    • 마이크로전자및패키징학회지
    • /
    • 제28권4호
    • /
    • pp.85-89
    • /
    • 2021
  • AlGaN 기반 UV-C 발광다이오드(LEDs)에 전기화학적 전위차 활성화(EPA)에 의한 p-형 활성화를 진행하였다. 높은 저항과 낮은 전도도를 유발하는 중성 Mg-H의 복합체의 수소원자를 EPA를 이용하여 제거하여 p-형 활성화 효율을 높였다. 중성 Mg-H 복합체는 주요 매개 변수인 용액, 전압, 시간에 의해 Mg-과 H+로 분해되며, 2차 이온질량 분광법(SIMS) 분석을 통하여 개선된 정공 캐리어의 농도를 확인할 수 있었다. 이 메커니즘은 결국 내부 양자효율(IQE)의 증가, 광 추출 효율 향상, 역 전류 영역의 누설전류 값 개선, 접합 온도 개선 등을 이루어 결과적으로 UV-C LED의 수명을 향상시켰다. 체계적인 분석을 위해 SIMS, Etamax IQE 시스템, 적분구, 전류-전압(I-V) 측정 등을 사용하였으며, 그 결과를 기존의 N2-열 처리 방법과 비교 평가하였다.

KOH 활성화가 슈퍼커패시터용 콜타르 피치 활성탄소의 전기화학적 성능에 미치는 영향 (Influence of KOH Activation on Electrochemical Performance of Coal Tar Pitch-based Activated Carbons for Supercapacitor)

  • 허지훈;서민강;김학용;김익준;박수진
    • 폴리머
    • /
    • 제36권6호
    • /
    • pp.756-760
    • /
    • 2012
  • 본 연구에서는 콜타르 피치를 출발물질로 하여 KOH로 활성화시킨 슈퍼커패시터용 전극소재를 제작하였다. 콜타르 피치와 KOH의 활성화 비율을 1:4로 설정한 후 활성화 온도를 $600{\sim}900^{\circ}C$까지 $100^{\circ}C$ 단위로 4종류의 활성탄소를 제조한 후 피치계 활성탄소의 전기화학적 성능에 대한 KOH 활성화 온도의 영향에 관하여 고찰하였다. 또한 활성탄소의 형태학적 특성 변화를 흡착등온선과 FE-SEM을 통하여 분석하였다. 실험결과, 활성탄소의 커패시턴스는 전극 내 내부저항의 감소에 따라 증가하였는데, 이는 활성화 온도가 증가함에 따라 활성탄소 내 미세기공이 발달했기 때문이라 판단된다.

Ni 및 Cu무전해 도금법에 의해 제조한 $LaNi_5$ 전극의 전기화학적 특성 (Electrochemical Characteristics of $LaNi_5$ Electrode Fabricated by Ni and Cu Electroless Plating Techniques)

  • 이수열;이재봉
    • 전기화학회지
    • /
    • 제3권2호
    • /
    • pp.121-126
    • /
    • 2000
  • [ $AB_5$ ] 수소저장합금인 $LaNi_5$, 합금분말에 Ni 및 Cu 무전해 도금의 영향을 전기 화학적 실험을 통하여 고찰하였다. 전기 화학적 실험은 정전류 충$\cdot$방전 실험, 순환전류전위 실험, 교류 임피던스 실험 등을 실시하여 도금하지 않은 $LaNi_5$ 전극과 Ni 및 Cu 무전해 도금한 전극간의 특성을 비교 연구하였다. 현상학적인 분석으로는 SEM을 이용하여 분말상의 미세조직을 관찰하였으며 X-선 회절시험을 실시하였다 무전해 도금을 실시하여 Ni 및 Cu박막이 피복된 수소저장 합금은 활성화 특성파 싸이클 수명 등의 특성이 개선되었으며 도금하지 않은 전극에 비하여 반응속도가 증가하였다. 또한 충$\cdot$방전이 반복됨에 따라 전극과 전해질 계면에서의 전하이동저항이 현저하게 감소하였다. 따라서 본 연구에서 실시한 $LaNi_5$, 활물질에 Ni및 Cu 무전해 도금을 실시하면 초기 활성화반응을 촉진시키며 $LaNi_5$활물질이 전해질과의 직접 접촉을 피하게 되어 전극의 수명을 증가시키는 것을 알 수 있었다.