• Title/Summary/Keyword: electrification

Search Result 235, Processing Time 0.037 seconds

A Basic Study on Electrification Phenomena of Synthetic Polymer Material (합성고분자재료의 대전현상에 관한 기초연구)

  • 이덕출;한상옥
    • 전기의세계
    • /
    • v.28 no.10
    • /
    • pp.48-54
    • /
    • 1979
  • The electrification phenomena of polymerized materials is governed by the competitive processes of the charge generation and the charge dissipation. In this paper, The charged particles were supplied on the naked upper surface of the polyethylene film from a point corona discharge with a screen electrode which controls the potential difference across the film. The charging current with the corona charging was found to be larger than that obtained with the electric charging on the MIM structure and the discharge current was found to flow in the same direction as that of the charging current. these results can suggest that the charge injection occurs from the interface between the polethylene surface and the accumulated charge layer, the injected charge are trapped and the space charge is established.

  • PDF

The Effect of Additive on the Electric conductivity of Insulating Oil (절연유의 전기전도에 미치는 첨가제의 영향)

  • 정광현;김영봉;김용운;임헌찬;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.158-161
    • /
    • 1996
  • The static charges are generated by streaming electrification phenomena in insulating oil flowing by force for the purpose of cooling at the internal of Ultra-high power transformer. In this thesis, their elimination method was studied. In this paper the effect of Additive on the electric conductivity of Insulating oil is studied. The variation of electric conductivity disappear when Additive is molten in insulating oil BTA(Benzotriazole) appear more variation of electric conductivity than that of SP-S10(Sorbitan mono-stearate). But the variation is not enough to decrease streaming electrification of insulating oil($\sigma$>10$\^$-12/[S/cm]).

  • PDF

Electrical properties of insulating oils for automobile ignition coil (자동차 점화코일용 절연유의 전기적 특성)

  • 신종열;홍진웅
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.172-177
    • /
    • 1999
  • In this paper, the physical and electrical properties of the synthetic fluids No. 2 class Ⅶ used the insulating oils for automobile ignition coil are studied. Also, benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of physical and electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown and the changes of conductivity by measuring volume resistivity are analyzed. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown and volume resistivity test.

  • PDF

A Study on Physical Properties of $PAN-CuSO_4$ Electroconductive Fiber and Wool Blended Fabrics (아크릴-황산동 복합체로 제조한 도전성 섬유 및 혼방한 모직물의 물성에 관한 연구)

  • 정영진;이명환;최해욱;이기환
    • Textile Coloration and Finishing
    • /
    • v.11 no.4
    • /
    • pp.8-15
    • /
    • 1999
  • Electroconductive fiber was obtained by acryl fiber treated with $CuSO_4$. The Properties and structure of fiber and fabric such as mechanical property, electrical conductivity, fine structure, electrification were investigated. The experimental results are as follows 1) The electrical conductivity of the conducting fiber was greatly increased but fine structure and physical properties were similar to acryl fiber 2) Fabric made by mix spinning with conducting fiber was shown great electrification effect. 3) In the mix spinning with conducting fiber, it was necessary to use different. finishing such as milled finish because stiffness of fabric made by mix spinning with conducting fiber was increased and elastic recovery was decreased. 4) The antimicrobial activity of electroconductive fiber blended wool was effective by Cu component for shake flask test.

  • PDF

Study on the Streaming Electrification of Insulating oil Under Electricfield (전계가 가해진 절연유의 유동대전 특성 고찰)

  • 허창수;정중일
    • Electrical & Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.334-341
    • /
    • 1997
  • Streaming electrification on insulating paper and pressboard under D.C. and A.C. electric field was investigated by using paper tubes and oil circulation apparatus. At first, flowing of static charges as measured with no electric field. As the temperature of oil increased, the measured current curve hows peak. As the velocity increased, it shows increasing exponential curve. Then, we applied A.C. and D.C. electric field on paper tube and the current from relaxation tank to earth was measured, which other factors such as temperature and velocity were varied like case of no electric field. The ions in oil carry the charges. So electric field makes asymmetry effect, and electrophoretic effect on ions in oil. We find that as the electric field intensity increased, the charges which were made by electric double layer were increased. The charge vs. velocity curve made peak point at a velocity.

  • PDF

The Electrical Conduction Characteristics of Transformer Oils added the Anti-static Agent for Streaming Electrification (유동대전 억제제가 첨가된 변압기유의 전기전도 특성)

  • Lee, Yong-Woo;Lee, Tae-Hoon;Oh, Se-Young;Lee, Jong-Pil;Cha, Kwang-Hoon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1213-1215
    • /
    • 1997
  • In order to investigate the electrical characteristics due to the BTA(Benzotriazole) additive in the transformer, the electrical characteristics of the transformer oils contained benzotriazole as an anti-static agent for streaming electrification is studied by measuring the electric conduction. As a result of the electrical conduction characteristics, it is confirmed that the conduction current of virgin specimen is more higher than that of specimen contained the BT A 10[ppm] over 35[$^{\circ}C$], but that of specimen contained the BT A 10[ppm] over 50[$^{\circ}C$] is increased.

  • PDF

The Effect of Antistatic Agent for Streaming Electrification on the Breakdown Characteristics of Synthetic Fluids (합성절연유의 절연파괴 특성에 미치는 유동대전 억제제의 영향)

  • Song, Byung-Gi;Lee, Soo-Won;Shin, Jong-Yeol;Shin, Hyun-Teak;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1414-1416
    • /
    • 1997
  • The electrical breakdown characteristics of the synthetic fluids No.2 of KS class VII used for insulating and cooling the materials for the ignition coil are studied. Also, Benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown are analyzed. The breakdown strength of specimen by adding BTA is higher than virgin specimen in low e region, but lower than that in high region because of melting BTA. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown.

  • PDF

Study on Remote Monitoring System for manned island electrification in Korea (하화도 태양광발전시스템의 원격측정 시스템 연구)

  • Lee, Man-Geun;Jung, Myung-Woong;Kim, Bu-Ho
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.7-14
    • /
    • 1996
  • Korean goverment is promoting "the Rural Electrification Project" to replace the diesel generators with PV power supply. The PV-diesel hybrid system are proven more cost effective than that of the existing, especially in the. case of small islands(less than 70 households). In this paper, we intend to introduce the Hahwado island PV system assisted with diesel generator and remote monitoring systems as observator. The purpose of this observator is to have minimum maintenance, to improve economical effciency and system reliability by checking the system periodically at certain time interval, and to make diagnosis of its operating situations. The remote monitoring system was designed to communicate between the central and local site through exclusive telephone line on real-time base, using Window '95 version.

  • PDF

A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC) (폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구)

  • 박구범;황명환;조기선;이덕출;임헌찬
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.

  • PDF

A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer (변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구)

  • 권석두;남상천
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF