• 제목/요약/키워드: electrical test

검색결과 7,386건 처리시간 0.032초

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

시드 병합을 통한 테스트 데이터의 압축방법 (SMC: An Seed Merging Compression for Test Data)

  • 이민주;전성훈;김용준;강성호
    • 대한전자공학회논문지SD
    • /
    • 제42권9호
    • /
    • pp.41-50
    • /
    • 2005
  • 회로가 커짐에 따라 테스트 데이터양이 증가하고, 테스트 적용시간이 길어지고 있다. 따라서 테스트 데이터양과 테스트 적용시간을 줄이기 위해서, 테스트 데이터의 압축/복원을 위한 새로운 방법을 제안하고자 한다. 제안하는 방법은 시드 벡터를 생성할 때, 압축률을 높이기 위해 무상관비트를 사용하는 XOR 트리에 기반을 두고 있다. 시드 벡터가 생성이 되면, 2비트 길이를 가진 코드를 사용하여 시드를 병합한다. 이렇게 병합된 시드는 1 클럭 시간동안에 재사용될 수가 있어, 테스트 데이터 적용시간을 크게 감소시킬 수 있다 제안하는 방법의 효율성은 ISCAS '89 벤치 회로에 대한 실험 결과로 알 수 있다.

Al2O3 첨가에 따른 송전용 현수애자의 전기적 성능 평가 연구 (A Study on the Electric Performance of Porcelain Insulator with Al2O3 Addition in Transmission Line)

  • 최인혁;최장현;이동일;최연규;조한구;한세원;박영창
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.96-103
    • /
    • 2005
  • To analyze the reason of aging deterioration in transmission line insulators, we performed a various kind of test and investigated mechanical and electrical characteristics of insulators. Test samples consisted of K-1989(36,000lbs), K-1995(36,000lbs) and K-2001(36,000lbs) type insulators which have been used in domestic 154 kV transmission lines. As a result of this test, the facts turned out K-2001 insulator which contain 17 wt.% alumina has better physical characteristics than K-1989 insulator which contain 8 wt% alumina. Relativity density and fracture toughness of K-1989 porcelain are 94.2 % and 1.4 MPa\ulcornerm$^{1}$2// but relativity density and fracture toughness of K-2001 porcelain are 96 % and 1.7 MPa\ulcornerm$^{1}$2//. K-2001 insulators show a good performance not only in a physical property test but also in power arc test and steep front of wave flashover test which is performed to evaluate electrical characteristics.

GIS용 피뢰기 누설전류 측정장치 성능개선 (The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.

송전용 자기재 애자의 성능평가 및 가속열화시험 (Study on Performance and Aging Test of Porcelain Insulators for Transmission Line)

  • 한세원;조한구;박기호;이동일;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석 (Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System)

  • 박재범;김미성;노대석
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

A New Multi-site Test for System-on-Chip Using Multi-site Star Test Architecture

  • Han, Dongkwan;Lee, Yong;Kang, Sungho
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.293-300
    • /
    • 2014
  • As the system-on-chip (SoC) design becomes more complex, the test costs are increasing. One of the main obstacles of a test cost reduction is the limited number of test channels of the ATE while the number of pins in the design increases. To overcome this problem, a new test architecture using a channel sharing compliant with IEEE Standard 1149.1 and 1500 is proposed. It can significantly reduce the pin count for testing a SoC design. The test input data is transmitted using a test access mechanism composed of only input pins. A single test data output pin is used to measure the sink values. The experimental results show that the proposed architecture not only increases the number of sites to be tested simultaneously, but also reduces the test time. In addition, the yield loss owing to the proven contact problems can be reduced. Using the new architecture, it is possible to achieve a large test time and cost reduction for complex SoC designs with negligible design and test overheads.

Micromechanical 시험법과 전기적 고유저항 측정을 이용한 탄소섬유강화복합재료의 계면 물성과 경화거동에 관한 연구 (Interfacial Properties and Curing Behavior of Carbon Fiber/Epoxy Composites using Micromechanical Techniques and Electrical Resistivity Measurement)

  • 이상일;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.17-21
    • /
    • 2000
  • Logarithmic electrical resistivity of the untreated or thin diameter carbon fiber composite increased suddenly to the infinity when the fiber fracture occurred by tensile electro-micromechanical test, whereas that of the ED or thick fiber composite increased relatively broadly up to the infinity. Electrical resistance of single-carbon fiber composite increased suddenly due to electrical disconnection by the fiber fracture in tensile electro-micromechanical test, whereas that of SFC increased stepwise due to the occurrence of the partial electrical contact with increasing the buckling or overlapping in compressive test. Electrical resistivity measurement can be very useful technique to evaluate interfacial properties and to monitor curing behavior of single-carbon fiber/epoxy composite under tensile/compressive loading.

  • PDF

전기 자극이 치주인대세포와 치은섬유아세포에 미치는 영향 (Effect of the Electrical Stimulation on the Human Periodontal Ligament Cells and Gingival Fibroblasts)

  • 이욱;박준봉;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제29권4호
    • /
    • pp.821-838
    • /
    • 1999
  • On the basis of the evidences that electrical stimulation could enhance proliferation and differentiation of bone cells and promote healing and regeneration of bone, this study was performed to investigate the effects of electrical stimulation on human periodontal ligament cells and gingival fibroblasts in vitro, which also have important roles in regeneration of periodontium, and to evaluate the potential of clinical application of electrical stimulation. Human periodontal ligament cells and gingival fibroblasts were primarily cultured from the root surface of extracted premolar and the adjacent gingiva without periodontal diseases. In control group, the cells ($5{\times}10^4$ cells/ml)were incubated only in Dulbecco's Modified Eagle's Medium contained with 10% fetal bovine serum. In test groups, electrical stimulation was given at the current intensity of $0.25{\mu]A$(test group 1), $1.0{\mu}A$(test group 2), and $2.5{\mu}A$(test group 3) for 12 hours to the same culture media with the control group. After 12 hour exposure of electrical stimulation, the cells were incubated for 2 and a half days(60 hours), and then each group of cells was analyzed for cell proliferation, protein level, and activity of alkaline phosphatase. The results were as follows ; 1. The Rate of cell proliferation of every test group increased significantly in both periodontal ligament cells and gingival fibroblasts, and in periodontal ligament cells, test group 3 showed significantly increased proliferation compared to the other test groups(p<0.05). 2. In the protein levels, neither periodontal ligament cell nor gingival fibroblast showed statistically significant differences between control and test groups. 3. The activity of alkaline phosphatase in periodontal ligament cells increased significantly in all test groups(p<0.05), but there were no significant differences between 3 test groups. In gingival fibroblasts, the activity of alkaline phosphatase increased significantly only in test group 3(p<0.05). From the above results, it is concluded that electrical stimulation may have beneficial effects on the regeneration of destructed periodontal tissue in regard of the stimulation of periodontal ligament cells and gingival fibroblasts as well as electrically stimulated bone formation that has been known, and that electrical stimulation may have the potential of clinical application.

  • PDF

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.