• Title/Summary/Keyword: electrical test

Search Result 7,386, Processing Time 0.043 seconds

Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기의 운전특성)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

Effects of Combined Functional Electrical Stimulation and Joint Mobilization on Muscle Activation and Mobility of Ankle Joints and Modified Functional Reach Test in Stroke Patient

  • Kim, Su-Jin;Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.41-51
    • /
    • 2019
  • PURPOSE: This study was conducted to investigate the effects of combined Joint Mobilization and Functional Electrical Stimulation on Muscle Activation and Mobility of ankle joints in stroke patients and their Modified Functional Reach Test (MFRT) results. METHODS: A total of 26 patients with stroke were randomly selected for enrollment in this study. (1) Functional Electrical Stimulation (FES) (2) combined Joint Mobilization and FES. An EMG system was used to measure tibialis anterior and gastrocnemius activities. Range Of Motion (ROM) of Ankle Joint and MFRT for Dynamic Balance. Pre and post intervention results were compared by paired-t-tests and differences in changes after intervention between groups were identified by the independent t-test. RESULTS: The muscle activation, ROM, and MFRT differed significantly in the experimental group (p<.05). The ROM was significantly different for the active dorsiflexion pre and post intervention in the group that received FES alone (p<.05). CONCLUSION: The results of this study suggest use of a systematic program of proactive posture control to prevent dysfunction when planning interventions for ankle joints can help stroke patients walk efficiently.

Development and characterization of graphite reinforced conductive polymer composites for PEMFC bipolar plates (고분자전해질 연료전지용 흑연계 복합소재 분리판 개발)

  • Heo Seongil;Yun Jincheol;Oh Kyeongseok;Han Kyungseop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.248-251
    • /
    • 2005
  • Graphite reinforced conductive polymer composites for PEMFC bipolar plates were fabricated by the compression molding technique. Graphite powder was mixed with an phenol resin to impart electrical property in composites. In this study, conductive polymer composites with high filler $loadings(>60wt.\%)$ were manufactured to accomplish high electrical conductivity above 100S/cm. The level of compaction is important because graphite powder increase electrical conductivity of composites by direct physical contact between particles. The optimum molding pressure according to filler was proposed experimentally. Various tests(electrical conductivity, flexural strength, compressive strength, leach test, etc) were carried out to verify the performance of fabricated composites for PEMFC bipolar plates. Fabricated composites have good electrical conductivity and mechanical strength. The results of leach test and contact angle measurement showed similar characteristics compared with commercial bipolar plates.

  • PDF

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Analysis of Deterioration Characteristics for Connection Factor used in Grounding System (접지시스템에 사용되는 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.9-13
    • /
    • 2015
  • This paper describes the analysis of deterioration characteristics for connection factor used in grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

A Study on the Electric Performance of NGK Porcelain Insulators for long period use in 154kV Transmission Line (외산 154kV NGK 노후애자의 전기적 성능 평가)

  • Choi, In-Hyuk;Park, Hyun-Min;Won, Gyeong-Bae;Kang, Dong-Hoon;Shin, Koo-Yong;Kim, Young-Hong;Kim, Min-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.426-428
    • /
    • 2015
  • The NGK suspension insulators are subjected in harsh environments in service above 40 years long time. The long term reliability of the insulators is required for both mechanical and electrical performances. This study describes some electrical performances according to KEPCO-standard. There was fail in electrical and mechanical performance test such as galvanizing, low-frequence wet flashover voltage, puncture and combine mechanical & electrical strength test. The NGK suspension insulators of 1968 were shown lower electrical and mechanical performance than those of 1979.

  • PDF

Prebreakdown Phenomena of $SF_{6}$ Gas in a Non-uniform Field Disturbed by a Metallic Protrusion

  • Lee, Kyoung-Ok;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.137-141
    • /
    • 1996
  • This paper deals with the prebreakdown phenomena of $SF_{6}$ gap stressed by non-oscillating and oscillating impulse voltages in a strong inhomogeneous field disturbed by a fred needle shaped-protrusion on the earth-side electrode. The breakdown voltage-time characteristics were measured for both positive and negative polarities and over the gas pressure range of 0.1∼0.5 MPa, and the temporal developments of the 77breakdown were observed by a shunt of 50 n. The dependence of the leader stopping time on the gas pressure were obtained. The local field enhancement due to the space charges, which is produced by the streamer corona, has influence with the electrical breakdown of the test gap. The test streamer corona is oxy a necessary condition for the electrical breakdown and the subsequent ionization activities launch the leader at the local field region.

  • PDF

Evaluation of Heat Treatment of an Al-Si Alloy forging by Using Its Relationship between Electrical Conductivity and Hardness (경도-전기전도도 상관관계를 이용한 A1-Si 알루미늄합금 열간 단조품의 열처리상태 평가)

  • 이석원;전만수;이준현
    • Transactions of Materials Processing
    • /
    • v.10 no.5
    • /
    • pp.418-424
    • /
    • 2001
  • In this study, a relationship between hardness and electrical conductivity for an Al-Si aluminum alloy, forged after extruded, is investigated. Microvickers hardness is measured and compared with its corresponding electrical conductivity obtained by the eddy current test. It is found that a distinct relationship between the hardness and the electrical conductivity exists for the material. Using the relationship, the hardness of forging is predicted from the electrical conductivity obtained by eddy current test and the result is used to evaluate the condition of heat treatment.

  • PDF

An Analysis or Starting and Driving Characteristics of Synchronous Motor (동기전동기의 시동 및 운전특성 해석)

  • Park, Han-Kyu;Song, Ho-Shin;Hwang, Jung-Weon;Cho, Yong-Kil;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.232-234
    • /
    • 1994
  • In this paper. to estimate starting torque of synchronous motor by simple test, we propose a new method which is the combination of commercial tests and single phase AC applied test of synchronous motor. A driving characteristic was examined when field winding is supplied a de and chopper current. The starting characteristics are assumed and agreed with actual data.

  • PDF