• 제목/요약/키워드: electrical test

검색결과 7,386건 처리시간 0.031초

트래킹 휠 시험에 의해 열화된 폴리머애자의 섬락특성 평가 (The Evaluation of Flashover Characteristics of Polymer Insulators with Tracking Wheel Test)

  • 이병성;한재홍;윤태상;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.82-85
    • /
    • 2000
  • Polymeric composite insulators are used for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate the tracking resistance of polymer insulators, we performed the tracking wheel test which is recommended by CEA LWIWG-01. And the flashover voltage tests were conducted for understanding electrical characteristics after tacking wheel test. Also, these insulators are studied by characterization methods such as contact angle measurement, SEM, etc.

  • PDF

측정불확도를 고려한 배터리 교환형 전기버스용 접속기 접촉저항 평가에 관한 연구 (A Study of Contact Resistance Test Considered with Measurement Uncertainty for Electric Bus Couplers with Battery-Swapping System)

  • 김광민;이주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.60-64
    • /
    • 2015
  • Many people think that Electric Vehicles(EVs) is the best method to resolve the problems of running out of fossil fuels. But EVs take long time for charging. So, EVs with battery swapping systems(EVBS) are developed to resolve this problem. Nonetheless, EVBS is not spreaded widely because the method of durability test in couplers is not defined. In this study, the evaluation method of durability test in couplers is defined by some standards and the measurement uncertainty is used to increase the reliability of EV couplers.

집적회로 응용을 위한 빗살형 캐패시터의 특성연구 (Characterization of Interdigitated Capacitors for Integrated Circuit Application)

  • 김길한;이규복;김종규;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.130-133
    • /
    • 2004
  • The characterization of interdigitated capacitors was investigated. The test structures are manufactured by low temperature co-fired ceramic(LTCC) process and their s-parameters were measured. The optimized equivalent circuit models for test structures were obtained using the partial element equivalent circuit(PEEC) method. Predictive modeling was performed on different test structures using optimized parameters to verify the circuit models. From this result, the manufacturability on the process can be improved through the predictive modeling for the characteristics of interdigitated capacitors.

  • PDF

Theoretical and experimental investigation of piezoresistivity of brass fiber reinforced concrete

  • Mugisha, Aurore;Teomete, Egemen
    • Computers and Concrete
    • /
    • 제23권6호
    • /
    • pp.399-408
    • /
    • 2019
  • Structural health monitoring is important for the safety of lives and asset management. In this study, numerical models were developed for the piezoresistive behavior of smart concrete based on finite element (FE) method. Finite element models were calibrated with experimental data collected from compression test. The compression test was performed on smart concrete cube specimens with 75 mm dimensions. Smart concrete was made of cement CEM II 42.5 R, silica fume, fine and coarse crushed limestone aggregates, brass fibers and plasticizer. During the compression test, electrical resistance change and compressive strain measurements were conducted simultaneously. Smart concrete had a strong linear relationship between strain and electrical resistance change due to its piezoresistive function. The piezoresistivity of the smart concrete was modeled by FE method. Twenty-noded solid brick elements were used to model the smart concrete specimens in the finite element platform of Ansys. The numerical results were determined for strain induced resistivity change. The electrical resistivity of simulated smart concrete decreased with applied strain, as found in experimental investigation. The numerical findings are in good agreement with the experimental results.

인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성 (A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation)

  • 김영석;최명일;김종민;방선배;송길목;곽동순
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

Analysis on electrical and thermal characteristics of MI-SS racetrack coil under conduction cooling and external magnetic field

  • Chae, Yoon Seok;Kim, Ji Hyung;Quach, Huu Luong;Lee, Sung Hoon;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.61-69
    • /
    • 2021
  • This paper presents the analysis and experiment results on the electrical and thermal characteristics of metal insulation (MI) REBCO racetrack coil, which was wound with stainless steel (SS) tape between turn-to-turn layers, under rotating magnetic field and conduction cooling system. Although the field windings of superconducting rotating machine are designed to operate on a direct current, they may be subjected to external magnetic field due to the unsynchronized armature windings during electrical or mechanical load fluctuations. The field windings show the voltage and magnetic field fluctuations and the critical current reduction when they are exposed to an external magnetic field. Moreover, the cryogenic cooling conditions are also identified as the factors that affect the electrical and thermal characteristics of the HTS coil because the characteristic resistance changes according to the cryogenic cooling conditions. Therefore, it is necessary to investigate the effect of external magnetic field on the electrical and thermal characteristics of MI-SS racetrack coil for further development reliable HTS field windings of superconducting rotating machine. First, the major components of the experiment test (i.e., HTS racetrack coil construction, armature winding of 75 kW class induction motor, and conduction cooling system) were fabricated and assembled. Then, the MI racetrack coil was performed under liquid nitrogen bath and conduction cooling conditions to estimate the key parameters (i.e., critical current, time constant, and characteristic resistance) for the test coil in the steady state operation. Further, the test coil was charged to the target value under conduction cooling of 35 K then exposed to the rotating magnetic field, which was generated by three phrase armature windings of 75 kW class induction motor, to investigate the electrical and thermal characteristics during the transient state.

Weil-Dobke 합성단락시험로의 최적화 연구 (A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests)

  • 김맹현;고희석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구 (A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS))

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가 (Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

시험용 변압기 내 부분방전의 초음파 검출에 관한 연구 (Detection of Acoustic signals by PD in Test Transformer)

  • 곽희로;권동진;진상범;전상준;정용기;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1293-1295
    • /
    • 1995
  • This paper describes the detection of the ultrasonic signals reduced by barrier in test transformer. The ultrasonic signals are generated by partial discharges which cause the insulation failure of transformer. The ultrasonic signals are reduced by barrier. But it was shown that the reduced ultrasonic signals can be measured as the location of the ultrasonic signal detectors is selected properly.

  • PDF