• 제목/요약/키워드: electrical test

검색결과 7,386건 처리시간 0.034초

Physical and electrical properties of PLA-carbon composites

  • Kang Z. Khor;Cheow K. Yeoh;Pei L. Teh;Thangarajan Mathanesh;Wee C. Wong
    • Advances in materials Research
    • /
    • 제13권3호
    • /
    • pp.211-220
    • /
    • 2024
  • Polylactic acid or polylactide (PLA) is a biodegradable thermoplastic that can be produced from renewable material to create various components for industrial purposes. In 3D printing technology, PLA is used due to its good mechanical, electrical, printing properties, environmentally friendly and non-toxic properties. However, the physical properties and excellent electrical insulation properties of PLA have limited its application. In this study, with the carbon black (CB) as filler added into PLA, the lattice spacing and morphology were investigated by using X-ray diffraction (XRD) and scanning electron microscope (SEM), respectively. The physical properties of PLA-carbon composite were evaluated by using tensile test, shore D hardness test and density and voids measurement. Impedance test was conducted to investigate the electrical properties of PLA-Carbon composites. The results demonstrate that the inclusion of carbon black as filler enhances the physical properties of the PLA-carbon composites, including tensile properties, hardness, and density. The addition of carbon black also leads to improved electrical conductivity of the composites. Better enhancement toward the electrical properties of PLA-carbon composites is observed with 1wt% of carbon black in N774 grade. The N550 grade with 2wt% of carbon black shows better improvement in the physical properties of PLA-carbon composites, achieving 10.686 MPa in tensile testing, 43.330 in shore D hardness test, and a density of 1.200 g/cm3 in density measurement. The findings suggest that PLA-carbon composites have the potential for enhanced performance in various industrial applications, particularly in sectors requiring improved physical and electrical properties.

전기자극이 치조골 치유과정에 미치는 영향 (EFFECT OF ELECTRICAL STIMULATION ON BONE FORMATION IN THE EXTRACTION SOCKET OF RAT)

  • 양승한;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.669-687
    • /
    • 2001
  • On the basis of the evidence that electrical stimulation could promote healing and regeneration of bone, this study was performed to investigate the effects of electrical stimulation on rat extraction socket, and to evaluate the potential of clinical application of electrical stimulation. Forty rats were used and divided into control groups(l0)and the experimental groups(30) in this study. The maxillary 1st molar were extracted in both groups. In experimental group, electrical stimulation was given at the current intensity of lmA(Test-1), l0mA(Test-2), 25mA(Test-3) each day. At 1,3,5,7 days after the tooth extraction, rats in both groups were serially sacrificed. And the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows; 1. At 1 day after the extraction, the periodontal ligament was found in the extraction socket wall. The formation of blood clot with dense infiltration of inflammatory cells in control group and there were less inflammatory cells in test group. 2. At 3 day after the extraction, the cells and collagen of the periodontal ligament were so actively proliferated and synthesized that invaded into the connective tissue of the extraction sockets in the control group. There were the formation of new bone in the basal & lateral portion of socket wall in test -2 and -3. 3. At 5 days after the extraction, there were no formation of new bone in control group. But the more electrical stimulation was applied, the more formation of new bone in test group. 4. At 7 days after the extraction, the extraction sockets were almost filled with trabecular bone in each group. Bone maturarity was remarkable in test-3. 5. The electrical stimulation at l0mA and 25mA was more effective in the bone formation at 5 and 7 days after the extraction. From the above results, electrical stimulation could promote the extraction socket wound healing, and be utilized in the clinical application of the residual ridge expansion.

  • PDF

위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험 (Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences)

  • 유정현;김희식;정용욱
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

유연 기판상 ITO 전극의 굽힘변형 및 굽힘피로에 따른 전기적 신뢰성 연구 (Electrical Reliability of ITO Film on Flexible Substrate During bending Deformations and Bending Fatigue)

  • 설재근;김병준
    • 마이크로전자및패키징학회지
    • /
    • 제24권4호
    • /
    • pp.47-52
    • /
    • 2017
  • 휘거나 구부릴 수 있는 유연 전자 소자(flexible electronics) 개발을 위해 이러한 변형 조건에서 사용이 가능한 유연한 투명전극재료에 대한 많은 관심이 기울여 지고 있다. 본 연구에서는 현재 투명 전극 소재로 가장 널리 사용 중인 ITO 박막을 이용하여 굽힘 실험 및 반복 피로 실험을 진행하며 전기적 특성 변화를 연구 하였다. 응력 상태에 따른 차이를 보기 위해, ITO 필름의 상대적 위치에 따라 외측 및 내측 굽힘 두 조건으로 실험을 진행하였으며, 외측 굽힘보다 보다 내측 굽힘 조건에서 굽힘 실험 및 피로 실험 모두 우수한 전기적 안정성을 보였다. 외측 굽힘 및 내측 굽힘 시 응력 상태가 각각 인장 응력, 압축 응력이 ITO 필름에 가해지게 되며 이에 따라 균열 형성 및 전파 거동에 차이가 나타나는 것을 FE-SEM 표면 관찰을 통해 확인하였다. 이는 결국 전기적 안정성과도 밀접히 연관된 것을 확인하였다. 본 연구를 통해 가장 대표적인 투명전극재료인 ITO 필름의 다양한 기계적변형에 대한 신뢰성을 이해하고, 이를 통해 향후 고신뢰성 유연전자소자용 전극을 위한 디자인에 활용할 수 있을 것으로 기대한다.

주파수 차지확률을 이용한 음성검출기 제안 (Speech detection using the probability of spectral occupancy)

  • Hong, Seong-Bong;Ki, Tae-Young;Kim, Nam-Soo;Kim, Taejeong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 제13회 신호처리 합동 학술대회 논문집
    • /
    • pp.171-174
    • /
    • 2000
  • In this paper, we improve statistical-model-based speech detector using the probability that a speech occupies a frequency bin. While the previous method assumes speech energy occupies all the frequency components and use them with equal weights in the likelihood ratio test for speech detection, the proposed method assumes speech energy occupies just some frequency componets and use them with different weights in accordance with the probabilities of spectral occupancy in the test. The probability is iteratively up-dated for speech frames to contribute to the likelihood ratio test. The proposed method well reflects the characteristic distribution of speech spectrum, and yields better detection performance.

  • PDF

회귀분석을 이용한 전자접촉기의 접점소모 분석에 대한 고찰 (A study on Analysis of Contact erosion at a Magnetic Contactor with the Use of Regression Analysis)

  • 김명석;유행수;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2003
  • This paper describes a Accelerated Life Test (ALT) with the electrical contact erosion suitable to the evaluations of high-reliability and durability devices such as magnetic contactor. Recently, an electrical devices company was interested in accelerated life test (ALT), the product liability (PL) and the short-term testing model of electrical life test (ELT). In order to estimate a model for testing fee and period, need to the statistical analysis method with the acceleration factor(AF). Usually customer/manufacturer regard their device failure to the over-current or heavy duty condition, while devices view shape of contact erosion owing to operational duty problem. In this paper, additional method of evaluation estimated the operated cycles by weight of contact erosion with a used of regression analysis by MINITAB.

  • PDF

도전성 EMI 저감을 위한 구조체의 뇌격전류 분류율 분석 (Analysis of Lightning Current Distribution for Reducing the Conductive EMI in a Structure)

  • 조성철;이태형;엄주홍;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1630-1631
    • /
    • 2011
  • Lightning current distribution in a building directly hit was studied by using a scaled steel frame structure model. As the test current source, impulse current with the rise time of 10 ${\mu}s$ and sinusoidal current with the frequency of 30 kHz were used to confirm the validity of test results. The current distributions at both horizontal and vertical pillars were measured by using CT. From the test results, the reduction effect for the conductive EMI was verified and a design method reducing the conductive EMI was proposed.

  • PDF

Development of an Impedance Locus Model for a Protective Relay Dynamic Test with a Digital Simulator

  • Kim, Soo-Nam;Lee, Myoung-Soo;Lee, Jae-Gyu;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.167-173
    • /
    • 2011
  • This paper presents a method for the development of the impedance locus to test the dynamic characteristics of protective relays. Specifically, using the proposed method, the impedance locus can comprise three impedance points, and the speed of impedance trajectory can be adjusted by frequency deviation. This paper is divided into two main sections. The first section deals with the configuration of impedance locus with voltage magnitude, total impedance magnitude, and impedance angle. The second section discusses the control of the locus speed with the means of the deviation between two frequencies. The proposed method is applied to two machine equivalent systems with offline simulation (i.e., PSCAD) and real-time simulation (i.e., real-time simulation environment) to demonstrate its effectiveness.

전력 설비 시스템의 온라인 감시 (On-line Condition Monitoring for Electric Equipments)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.103-105
    • /
    • 2008
  • In, this paper, we consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PO) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PO testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PO measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF