• 제목/요약/키워드: electrical resistivity.

검색결과 2,824건 처리시간 0.027초

A Study on Electrical Resistivity Behaviors of PAN-based Carbon Nanofiber Webs

  • Park, Soo-Jin;Im, Se-Hyuk;Rhee, John-M.;Lee, Young-Seak
    • Carbon letters
    • /
    • 제8권1호
    • /
    • pp.43-48
    • /
    • 2007
  • The influences of various carbonization temperatures on electrical resistivity and morphologies of polyacrylonitrile (PAN)-based nanofiber webs were studied. The diameter size distribution and morphologies of the nanofiber webs were observed by a scanning electron microscope. The electrical resistivity behaviors of the webs were evaluated by a volume resistivity tester. From the results, the volume resistivity of the carbon webs was ranged from $5.1{\times}10^{-1}\;{\Omega}{\cdot}cm$ to $3.0{\times}10^{-2}\;{\Omega}{\cdot}cm$, and the average diameter of the fiber webs was varied in the range of 310 to 160 nm with increasing the carbonization temperature. These results could be explained that the graphitic region of carbon webs was formed after carbonization at high temperatures. And the amorphous structure of polymeric fiber webs was significantly changed to the graphitic crystalline, resulting in shrinking the size of fiber diameters.

전기비저항(電氣比抵抗) 탐사(探査)에 의한 포항분지(浦項盆地)와 장기분지의 경계규명(境界糾明) (Investigation of Boundary between Pohang and Janggi Basins by Electrical Resistivity Survey)

  • 민경덕;윤혜수;문희수;이현구;이대하
    • 자원환경지질
    • /
    • 제23권2호
    • /
    • pp.215-219
    • /
    • 1990
  • Geological and electrical resistivity surveys along the survey line of about 3 km between Kyungsangbukdo Youngilgun Hodong and Gwangmyungdong using by dipole-dipole electrode array method were carried out to examine the boundary and structural relationship between Tertiary Pohang and Janggi basins. Electrical resistivity data were interpreted qualitatively and quantitatively by means of pseudosection of apparent electrical resitivity distribution and finite difference method for two dimensional geologic structure model. The nearly vertical fault zone with low electrical resistivity value of 1-5 Ohm-m and widths of about 200m at the surface and 400 m at depth exists around 1.2 km west of national road between Ocheoneup and Yangbukmyun. Mudrocks, sandstones and tuffaceous rocks are widely distributed with electrical resistivity values of 6-77 Ohm-m. Especially, tuffaceous rocks with relatively high electrical resistivity value are predominant at eastern side of fault zone. Consequently, it is known that Pohang and Janggi basins are in fault contact.

  • PDF

수은과 비소로 오염된 시료의 측정주파수와 농도 변화에 따른 전기적 특성 (Electrical Characteristics against Frequency and Concentration of Contaminated Soils by Mercury and Arsenic)

  • 손영환;봉태호;장병욱
    • 한국농공학회논문집
    • /
    • 제50권6호
    • /
    • pp.15-24
    • /
    • 2008
  • In general, ground pollution can be classified with soil pollution and underground water pollution. And ground pollution contaminates the land with garbage dumps and other harmful waste products as heavy metals that can also eventually enter our water supply. This study was conducted to define a characteristics of the electrical resistivity and the permittivity of weathered soil that was contaminated with heavy metals as Mercury and Arsenic. It is not easy whether contamination of soil as subsurface contamination is decided or not and at an early stage especially do that. Therefore the electrical resistivity and the permittivity were used to make up for this defects. These methods are more economical and more effective than the existing methods. And variation of the electrical resistivity and the permittivity values were found against the change of concentration of Mercury and Arsenic aqueous solutions and measuring frequency. These analyzed results indicate that the electrical resistivity and the permittivity tend to decrease against increasing measuring frequency. The electrical resistivity and the permittivity are also found to show the function of frequency.

매트릭스 강도, 섬유 형식 및 보강량에 강섬유 보강 시멘트 복합재료의 인발시 전기저항에 미치는 영향 (Effects of Matrix Strength, Fiber Type, and Fiber Content on the Electrical Resistivity of Steel-Fiber-Reinforced Cement Composites During Fiber Pullout)

  • ;김동주
    • 대한토목학회논문집
    • /
    • 제39권6호
    • /
    • pp.675-689
    • /
    • 2019
  • 자가응력 및 자가손상 감지능력을 모두 가지는 스마트 콘크리트의 개발은 아직까지 손상 감지 능력에 대한 원인 규명이 명확하지 않아 어려운 현실이다. 따라서, 본 연구에서는 매트릭스 강도, 섬유 형식 및 보강량이 강섬유 보강 시멘트 복합재료의 인발시 전기저항에 미치는 영향을 평가하였다. 실험으로부터 섬유와 매트릭스 사이 계면에서의 탈착으로 전기저항률이 감소한다는 사실을 알 수 있었다. 섬유와 매트릭스 사이 계면 부착강도가 높을수록 더 큰 전기저항률의 감소를 유발하였다. 따라서, 고강도 매트릭스, 황동 도금된 강섬유 그리고 변형된 강섬유를 사용시 높은 계면부착강도를 유발하고 그 결과 더 큰 전기저항률 감소를 유발하였다.

그라우팅에 의한 댐체의 보강효과 평가를 위한 전기비저항탐사 (Electrical Resistivity Survey for Evaluation of Grouting Effect in Earth Dam)

  • 임은상;오석훈;김영경;오병현
    • 지구물리
    • /
    • 제9권4호
    • /
    • pp.455-462
    • /
    • 2006
  • 본 연구에서는 그라우팅 효과를 간편히 그리고 합리적으로 평가하기 위한 방법의 하나로서 전기비저항 탐사에 대한 적용성을 검토하였다. 전기비저항 탐사를 통한 보강 효과를 보다 정확하게 이해하기 위해, 누수에 의한 코아의 세립분 유출이 코아부의 전기비저항에 어떤 변화를 발생시키는가에 대한 메커니즘을 분석하여 탐사시의 조건에 따라서 연약부분의 비저항이 낮아질 수도 높아질 수도 있다는 사실을 확인하였다. 이는 통상적으로 인식되어지고 있는 코아의 연역부분에서는 비저항이 낮아진다는 사실에 반하는 것으로서 이러한 메커니즘 하에서 실제 그라우팅에 의해 보수・보강이 수행된 댐체에 대한 보강 전・후의 전기비저항을 비교・분석하였으며, 그 결과 보강 후의 비저항이 균일한 분포를 나타내고 있다든지 비정상적인 이상 비저항대가 없어졌다든지 하는 그라우팅의 효과를 성공적으로 평가할 수 있었다. 즉, 그라우팅에 의한 효과를 평가하는데 있어서 전기비저항 탐사는 매우 효율적인 방법 중의 하나라는 것을 알 수 있다

  • PDF

Application of resistivity monitoring to examine the grouting effect

  • Farooq, Muhammad;Park, Sam-Gyu;Kim, Jung-Ho;Song, Young-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.79-82
    • /
    • 2006
  • This paper presents to examine the ability of an electrical resistivity method to monitor the grouting effect at subsidence area. To monitor the changes in ground resistivity before and during the grout, series of electrical resistivity monitoring surveys have been conducted. Data has acquired in the form of grid making nine lines parallel to road and four lines traverse the road. Two kinds of electrode arrays modify pole-pole and dipole-dipole arrays were used during resistivity data acquisition. In this paper, the results show that electrical prospecting is an effective method to detect low resistivity imaging zone by grout during the ground reinforcement.

  • PDF

전기비저항 수직탐사를 이용한 저수지 그라우팅 구간 평가 (Electrical resistivity survey for evaluation of reinforced region by cement grouting in dike)

  • 송성호;장의웅;김진호;김진성;김진춘
    • 지질공학
    • /
    • 제12권1호
    • /
    • pp.63-73
    • /
    • 2002
  • 누수 보강 저수지의 그라우팅 개선 구간 평가를 목적으로 물-시멘트 배합비별로 제조된 그라우트에 대하여 재령 변화에 따른 전기비저항과 압축강도 변화를 측정하였다. 동일 조건 하에서 그라우트의 농노가 증가할수록 전도도는 높아지고, 대상 매질에 그라우트가 주입되는 경우 주입 이전에 비해 비저항이 상대적으로 낮아지는 효과가 나타나므로 이를 이용한 주입 구간의 판정이 가능함을 확인하였다. 대상 매질이 서로 다른 세 지구에 대한 그라우팅 이후 전기비저항 수직탐사 결과 겉보기 비저항은 수십∼수백 ohm-m 이하로 낮아졌으며, 주입 이후 수 일이 지난 후부터는 점차 증가된 상태로 일정하게 유지되는 것으로 나타나는데, 이는 그라우트가 주입된 이후 대상 지층 내에서 굳어짐에 따른 강도 증가의 결과로 밝혀졌다.

전자빔 증착법으로 제작한 Cu 박막의 부착력과 저항율 특성 (The Resistivity Properties and Adhesive Strength of Cu Thin firms Fabricated by EBE Method)

  • 백상봉;신중홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.422-426
    • /
    • 2003
  • Cu thin films of $6000{\AA}$ thickness were deposited by Electron Beam Evaporation(EBE) method on the glass. The resistivity properties and adhesion of Cu thin films were investigated by various annealing and substrate temperature. Cu thin films were annealed in the air and vacuum condition for 10 min after the deposition. The resistivity and adhesion(the force required to separate films from substrates) was measured by 4-point probe and scratch testing. The resistivity of non-annealing Cu thin films was distinguished more substrate temperature loot than substrate temperature R.T, $200^{\circ}C$. In the case of air condition annealing, as heating temperature was increased, the resistivity was decreased. In the case of vacuum condition annealing, the resistivity was increased at heating temperature $200^{\circ}C$. The best resistivity($1.72\;{\mu}{\Omega}{\cdot}cm$) of Cu thin films was obtained by the air condition heating temperature $200^{\circ}C$ at the substrate heating temperature $100^{\circ}C$. As a result of scratch testing, adhesion was increased by annealing. And maximum adhesion had 600 gf.

  • PDF

Effect of exfoliated graphite nanoplatelets on the fracture surface morphology and the electrical resistivity of phenylethynyl-terminated polyimide

  • Cho, Dong-Hwan;Fukushima, Hiroyuki;Drzal, Lawrence T.
    • Carbon letters
    • /
    • 제13권2호
    • /
    • pp.121-125
    • /
    • 2012
  • In the present work, exfoliated graphite nanoplatelets (EGN) of 1 ${\mu}m$ in average particle size, which were prepared by heating at $900^{\circ}C$ and then subjected to ultrasonic, ball-milling, and vibratory ball-milling techniques, were uniformly incorporated into phenylethynyl-terminated polyimide (PETI-5) resin. The fracture surface morphology and the electrical resistivity of the EGN/PETI-5 composites were investigated. The results showed that the fracture surfaces and the electrical resistivity strongly depended on the EGN content. The fracture surfaces became more ductile and roughened with increasing EGN and the electrical resistivity was gradually decreased with increased EGN loading, indicating the percolation threshold at 5 wt% EGN.

지표 물리탐사법을 이용한 염/담수 영역의 고분해능 영상화

  • 박권규;신제현;박윤성;황세호
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.446-449
    • /
    • 2004
  • High resolution geophysical imaging to delineate costal aquifer and seawater- freshwater interface has been applied in Baesu-eup, Yeonggwang-gun, Jeolla province Electrical resistivity information from vertical electrical sounding and 2-D electrical resistivity survey is key parameter to map equivalent Nacl concentration map over the survey area. Seismic velocity from refraction tomographic survey, on the other hand, gives more reliable information on the subsurface stratagraphy than electrical resistivity methods which frequently suffer from low resolution due to masking effect. We imaged high-resolution 3-D structure of costal aquifer by correlating the electrical resistivity with seismic velocity, and mapped equivalent NaCl concentration map using resistivity and hydro-geological information from well logging.

  • PDF