• Title/Summary/Keyword: electrical resistivity.

Search Result 2,821, Processing Time 0.027 seconds

불포화 사질토 지반의 지반조건 및 침출수 오염도에 따른 전기비저항의 변화

  • 오명학;이주형;박준범;김형석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.47-50
    • /
    • 2001
  • The laboratory tests were peformed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. For weathered granite soil, the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases since leachate contains various ionic constituents. And the modified Archie's equation for applying to unsaturated sand is derived by regression analysis.

  • PDF

Influence of curing condition and carbonation on electrical resistivity of concrete

  • Yoon, In-Seok;Hong, Seongwon;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • v.15 no.6
    • /
    • pp.973-987
    • /
    • 2015
  • The electrical resistivity of air-dried, saturated, and carbonated concretes with different mixture proportions was monitored to evaluate and quantify the influence of the age of the specimen, carbonation, and curing condition. After 28 days of curing, four prepared specimens were stored in a vacuum chamber with 5% $CO_2$ for 330 days to make carbonated specimens. Four of the specimens were placed in water, and four specimens were cured in air until the end of the experiments. It was observed that the electrical resistivity of the carbonated specimens increased as carbonation progressed due to the decrease of porosity and the increase of hydrated products. Therefore, in order to estimate the durability of concrete, its carbonation depth was used as the measurement of electrical resistivity. Moreover, an increase of electrical resistivity for air-dried and saturated concretes was observed as a function of age of the specimen. From the relationship between chloride diffusivity provided by Yoon et al. (2007) and the measurements of electrical resistivity, it is expected that the results well be of significant use in calibrating chloride diffusivity based on regular measurements of electrical resistivity during concrete construction.

4 Electrical Resistivity Probe for Investigating soft offshore soils (해안연약 지반 조사를 위한 4전극 전기비저항 프로브)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Bae, Myeong-Ho;Jung, Soon-Hyuck;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.464-475
    • /
    • 2009
  • Electrical resistivity can be used for porosity estimation. In order to improve previously developed ERCP(Electrical Resistivity Cone Probe), 4ERP(4 Electrical Resistivity Probe), which has Wenner array at the tip of probes, has been developed. In properties of current flow Wenner array measures electrical properties of undisturbed area during penetration and relatively correct measurements are guaranteed without polarization. Furthermore, Wenner array equation can estimate electrical resistivity without extra calibration. 4ERP is developed into 2 types, penetration and fixation. Penetration type has wedge-shaped tip. Considering disturbance minimization, fixed type has plane tip. Fixed type 4ERP in consolidation cell measure electrical resistivity increment along porosity decrease, and penetration type 4ERP measured resistivity profile along the depth in chamber. Applying Archie's law, porosity profile was estimated with electrical resistivity. The tests result suggests that 4ERP can be new site investigation equipment with little disturbance.

  • PDF

The properties of copper films deposited by RF magnetron sputtering (RF 마그네트론 스퍼터링법에 의해 증착된 구리막의 특성)

  • 송재성;오영우
    • Electrical & Electronic Materials
    • /
    • v.9 no.7
    • /
    • pp.727-732
    • /
    • 1996
  • In the present paper, the Cu films 4.mu.m thick were deposited by RF magnetron sputtering method on Si wafer. The Cu films deposited at a condition of 100W, 10mtorr exhibited a low electrical resistivity of 2.3.mu..ohm..cm and densed microstructure, poor adhesion. The Cu films grown by 200W, 20mtorr showed a good adhesion property and higher electrical resistivity of 7.mu..ohm..cm because of porous columnar microstructure. Therefore, The Cu films were deposited by double layer deposition method using RF magnetron sputtering on Si wafer. The dependence of the electrical resistivity, adhesion, and reflectance in the CU films [C $U_{4-d}$(low resistivity) / C $U_{d}$(high adhesion) / Si-wafer] on the thickness of d has been investigated. The films formed with this deposition methods had the low electrical resistivity of about 2.6.mu..ohm..cm and high adhesion of about 700g/cm.m.m.

  • PDF

An Electrical Resistivity Monitoring in Embankment (제방에서의 전기비저항 모니터링)

  • Ahn, Taegyu;Ko, Chihye;Jeong, Yujeong;Lee, Heuisoon;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.59-67
    • /
    • 2015
  • An electrical resistivity survey is widely conducted for the safety management of embankment. In this study we investigated how a tidal variation affects the interpretation of electrical resistivity monitoring data of the embankment located in west coast. We monitored the variation of electrical resistivity on the coastal embankment where there was a high tidal variation for 3 days in every 3 hours. Electrical resistivity monitoring data showed a variation of resistivity distribution in specific area according to the time, which demonstrated some correlation with a tidal height variation. Therefore, we highly recommend that a tidal effect be considered when electrical resistivity survey is conducted on the embankment where there is a high tidal variation. For further study, we need a long term electrical resistivity monitoring and analyzing on tidal variation.

Subsurface Contaminant Leak Detection System using Electrical Resistivity Measurement (전기비저항을 이용한 지반오염누출감지시스템 개발)

  • 박준범;오명학;이주형
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.11a
    • /
    • pp.42-71
    • /
    • 2001
  • Leakage detection system can possibly locate leak point without laboratory analysis. Several different types of sensors provide these benefits. But the use of these technologies is not widespread, mainly because of cost. Each of the leakage detection systems available has different advantages and disadvantages. The ideal system would be affordable, durable enough to last through the life of the landfill, automated, and applicable to all types of landfills. The laboratory tests were performed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. The results of experiment show that the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases. These facts indicate that electrical resistivity method can be a promising tool in detecting of leachate. Also, the field model tests were conducted to verify that detection of leachate leak point on detection system using electrical characteristics is accurate. Field model test results of leakage detection system imply that the leakage detection system using electrical characteristics have the great potential of detecting exactly the leak point of leachate.

  • PDF

Electrical Resistivity of the $\beta$-SiC+39vol.%$ZrB_2$ Composites ($\beta$-SiC+39vol.%$ZrB_2$ 복합체의 전기저항률)

  • Shin, Yong-Deok;Ju, Jin-Young;Yoon, Se-Won;Hwang, Chul;Lee, Jong-Deok;Song, Joon-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1916-1918
    • /
    • 1999
  • The electrical conductive mechanism and temperature dependence of electrical resistivity of ${\beta}-SiC+ZrB_2$ composites with $Al_2O_3+Y_2O_3$ contents were investigated. The electrical resistivity of hot-pressed composites was measured by the Pauw method from $25^{\circ}C$ to $700^{\circ}C$. The electrical resistivity of the composites showed the PTCR(Positive Temperature Coefficient Resistivity) and follow the electrical conduction model for a homogeneous mixture of two kind of particles with different conductivity. Also, the electrical resistivity versus temperature curves indicate the formation of local chains of $ZrB_2$ particles.

  • PDF

A COMPARATIVE ANALYSIS BETWEEN GROUND SUBSIDENCE AT ABANDONED UNDERGROUND COAL MINE AND ELECTRICAL RESISTIVITY SURVEY RESULTS USING GIS

  • Ahn, Seung-Chan;Lee, Sa-Ro;Kim, Ki-Dong
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.728-731
    • /
    • 2006
  • Ground subsidence near abandoned underground coal mines has become a serious social problem in Korea. The purpose of this study is to perform a comparative analysis between the ground subsidence area and the electrical resistivity measured by field survey at Samcheok City. A raster database composed of ground subsidence areas and electrical resistivity data was constructed for GIS. To analyze correlation between the two constructed raster datasets, we used a frequency ratio model. The results show that low and high electrical resistivity anomaly zones coincide with the existing subsidence areas. We infer that the high anomaly zone means saturated and low anomaly zone means vacant. It suggests that electrical resistivity might be a useful factor for analyzing ground subsidence hazard zone.

  • PDF

Influence of Carbonation of Concrete on Electrical Resistivity (콘크리트의 탄산화가 전기저항에 미치는 영향)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.27-33
    • /
    • 2014
  • Electrical resistivity of concrete can be measured in a more rapid and simple way for estimating durability of the concrete, however, carbonation causes a result of misleading for durability testing because carbonation leads to a significant reduction in the permeability and porosity of concrete. The purpose of this study is to estimate and quantify the effect of carbonation of concrete on a surface electrical resistivity measurement. Samples of three mixes with difference w/c were prepared and exposed in a carbonation chamber for 330 days. The results show that carbonation leads high electrical resistivity. The increase is substantial and has been shown to proportional to the extent of the carbonation by some of extent. The relationship between electrical resistivity and carbonation depth is taken in the study. Resistivity ratio of carbonated concrete to air concrete decreased significantly from the specific carbonation depth, however, resistivity ratio of carbonated concrete to air concrete had a linear relation with carbonation depth. From the relationship between electrical resistivity and carbonation depth, it is expected that the result should be subsequently used as a calibration curve for estimating carbonated concrete to overcome the interruption effect of carbonation on regular measurements of the electrical resistivity.

The Electrical Resistivity of a SiCw/Al Alloy Composite with Temperature

  • Kim Byung-Geol;Dong Shang-Li;Park Su-Dong;Lee Hee-Woong
    • Korean Journal of Materials Research
    • /
    • v.14 no.7
    • /
    • pp.489-493
    • /
    • 2004
  • The electrical property of MMC is essentially important to some applications such as power transmission lines and cables, electronic and electrical components as well as electromagnetic shielding equipments. The behavior of electrical resistivity of $SiC_{w}/Al$ alloy composites under as-extruded and annealed conditions has been investigated within the temperature range from room temperature to $450^{\circ}C$. It can be seen that within entire temperature range, the electrical resistivity of composites was higher than that of an unreinforced matrix alloy under the same condition of either as-extrusion or annealing. The temperature dependence of both exhibited positive incline like a typical metal. The variation of electrical resistivity of an unreinforced matrix alloy with temperature from ambient temperature to $450^{\circ}C$ was nearly monotonous, while those of composites increased monotonously at low temperature and rose to a high level after about $250^{\circ}C or 275^{\circ}C$. The difference of these temperature dependences on electrical resistivity can be interpreted as qualitatively the interfaces of $SiC_{w}$ fibers and matrix, where act as nucleation sites.