• 제목/요약/키워드: electrical resistivity test

검색결과 284건 처리시간 0.029초

전기비저항과 암반등급의 상관관계에 대한 고찰 (A Study on the Correlation of Resistivity and Rock Quality)

  • 권형석;신중호;황세호;백환조;김기석;김종수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.81-88
    • /
    • 2001
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity is widely used in determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test in laboratory, such as uniaxial compressive strength(UCS), p wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity logging at in-situ area. Also we peformed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

물리탐사에 의한 터널구간의 암반등급 산정 (A Case Study for Rock Mass Classification using Geophysical Exploration)

  • 김기석;권형석;김종훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 암반역학위원회 학술세미나 논문집
    • /
    • pp.119-137
    • /
    • 2003
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity Is widely used In determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test In laboratory, such as uniaxial compressive strength(UCS), P wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity togging at In-situ area. Also we performed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

전기비저항과 암반분류의 상관관계에 대한 고찰 (A Study on the Correlation Between Electrical Resistivity and Rock Classification)

  • 권형석;황세호;백환조;김기석
    • 지구물리와물리탐사
    • /
    • 제11권4호
    • /
    • pp.350-360
    • /
    • 2008
  • 전기비저항은 땅의 여러 물리적 특성 중의 하나로 전기비저항 탐사, 전기비저항 검층과 실내시험 등을 통해 측정된다. 최근에 전기비저항은 도로나 철도터널의 지보형식 설계에서 미시추구간의 암반등급을 예측하는데 활용되는 등 그 활용도가 증가하고 있다. 전기비저항으로부터 신뢰할 수 있는 암반등급을 추정하기 위해서는 많은 현장시험과 함께 전기 비저항과 암반분류의 상관성에 대한 고찰이 요구된다. 본 연구에서는 먼저 암석시료에 대해 탄성파속도, 탄성계수, 일축 압축강도 등의 암석물성시험과 전기비저항 코어시험을 실시하였다. 시험결과로부터 획득된 전기비저항과 암석물성의 상관성을 분석한 결과 전기비저항이 암석물성과 높은 상관성을 가지고 있음을 확인하였다. 다음으로 일반적인 지반조사에 비해 현저히 많은 12개의 시추공에서 전기비저항 검층을 실시하여, 전기비저항 탐사 및 전기비저항 검층에 의한 전기비저항과 RMR의 상관성을 고찰하였다. 전기비저항 검층은 RMR과 80% 이상의 매우 높은 상관성을 보여 전기비저항을 이용하여 암반등급을 결정하는 방법이 과학적으로 타당하다는 것을 확인하였다. 이에 반해 전기비저항 탐사는 RMR과 20% 내외의 낮은 상관성을 가지는데 이는 단층파쇄대와 같은 저비저항 이상대가 역산에 영향을 미치기 때문으로 상관관계 분석시 신선한 암반, 절리파쇄대, 단층파쇄대로 그룹을 분리하여 상관성을 분석하면 신뢰성 있는 상관식을 도출할 수 있음을 확인하였다.

Micromechanical 시험법과 전기적 고유저항 측정을 이용한 탄소섬유강화복합재료의 계면 물성과 경화거동에 관한 연구 (Interfacial Properties and Curing Behavior of Carbon Fiber/Epoxy Composites using Micromechanical Techniques and Electrical Resistivity Measurement)

  • 이상일;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.17-21
    • /
    • 2000
  • Logarithmic electrical resistivity of the untreated or thin diameter carbon fiber composite increased suddenly to the infinity when the fiber fracture occurred by tensile electro-micromechanical test, whereas that of the ED or thick fiber composite increased relatively broadly up to the infinity. Electrical resistance of single-carbon fiber composite increased suddenly due to electrical disconnection by the fiber fracture in tensile electro-micromechanical test, whereas that of SFC increased stepwise due to the occurrence of the partial electrical contact with increasing the buckling or overlapping in compressive test. Electrical resistivity measurement can be very useful technique to evaluate interfacial properties and to monitor curing behavior of single-carbon fiber/epoxy composite under tensile/compressive loading.

  • PDF

원심모형실험을 위한 전기비저항 탐사 시스템 구축 (Development of Electrical Resistivity Survey System for Geotechnical Centrifuge Modeling)

  • 조형익;방은석;이명종;추연욱;김동수
    • 한국지반공학회논문집
    • /
    • 제30권10호
    • /
    • pp.19-31
    • /
    • 2014
  • 원심모형실험 중 지반모형의 상태 변화를 입체적으로 파악하기 위한 방법으로 전기비저항 탐사를 시도하였다. 탐사 시스템은 현장에서 널리 사용되는 검증된 상용 장비를 바탕으로 하였다. 컴퓨터 원격 조정으로 실험 시설 내에 설치된 탐사 장비를 통제하고 실시간 해석을 통해 결과 영상을 원심 모형실험 중에 바로 확인할 수 있도록 구성하였다. 구축된 탐사 시스템의 안정적 구동 여부를 점검하기 위해 불포화상태로 조성된 모형 지반 상단에 염수를 떨어뜨려 지반 내부로 이동하게 하고 전기비저항 탐사를 수행하였다. 10g로 원심력을 가한 상태에서 실험을 수행하고 시간대별 염수 침투상황을 전기비저항 영상으로 확인하였으며 일반 중력장에서 동일하게 실험한 결과와 비교하였다. 실험 종료 뒤 모형지반 수직 절단면을 이용하여 직접 측정한 전기비저항 값과 획득한 영상을 비교함으로써 신뢰성을 검증하였다.

대지저항률의 주파수 의존성 (Frequency relativity of soil resistivity)

  • 이복희;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.373-376
    • /
    • 2003
  • A new method measuring soil resistivity in frequency range of 5-500[KHz] using variable frequency inverter was presented, and soil resistivity was analysed by resistive and reactive components on the basis of magnitude and phase of measured ground impedance. The test lead arrangement was proposed to reduce the inductive coupling in test circuit for measuring the soil resistivity. The frequency dependence of soil resistivity was mainly caused by the inductive current flowing through grounding conductors over the frequency of 70[KHz].

  • PDF

오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가 (Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination)

  • 오명학;김용성;유동주;박준범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성 (Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil)

  • 손영환;봉태호;장병욱
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

흙의 구성광물과 간극수의 성분이 비저항값에 미치는 영향에 관한 연구 (A Study on the Effect of Soil Wineral and Component of the Pore Fluid to the Electrical Resistivity)

  • 윤춘경;유찬;윤길림
    • 한국환경농학회지
    • /
    • 제17권1호
    • /
    • pp.59-64
    • /
    • 1998
  • The environmental problem of the rural area has been accelerated in soil as well as water. Soil contamination is usually caused by improper operation of landfills, abandoned mine fields, accidental spills, and illegal dumpings. Once soil contamination is initiated, pollutants migrate and may cause groundwater contamination which takes much effort for remediation. Early detection, therefore, is important to prevent further contamination. Electrical resistivity method was used to detect soil contamination, but it was not effective to the heterogeneous condition. Static cone penetrometer test (CPT) has been used widely to investigate geotechnical properties of the underground. In this study, electrical resistivity method and CPT are combined to improve the applicability of it. The pilot test was performed to examine the variation of electrical resistivity with different soil minerals and pore fluid characteristics. Soil samples used were poorly graded sand, silty sandy soil, and weathered granite soil. For all the cases, electrical resistivity decreased with increasing of moisture content. Soil mineral also affected the electrical resistivity significantly. Above all, leachate addition in the pore fluid was very sensitive and caused decreasing of electrical resistivity markedly. It implies that electrical resistivity method can be applied to investigate pollutant plume effectively. This is specially sure when the sensors contact the contaminated soils directly. The CPT method involves cone penetration to the ground, therefore, underground contamination around the cone could be investigated effectively even for heterogeneous condition as it penetrates if electrical resistivity sensors are attached on the cone.

  • PDF