• Title/Summary/Keyword: electrical resistivity dipole-dipole

Search Result 87, Processing Time 0.028 seconds

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

Use of Two Dimensional Electrical Resistivity Tomography to Identify Soil Water Dynamics and the Effective Plant Root Zone

  • Yoon, Sung-Won;Zhang, Yong-Seon;Han, Kyung-Hwa;Jo, Hee-Rae;Ha, Sang-Keun;Park, Sam-Kyeu;Sonn, Yeon-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.3
    • /
    • pp.353-359
    • /
    • 2012
  • The identification of effective root zone would clarify dynamics of plant available water and soil water balance. Using the relationship between soil properties and electrical resistivity (ER) the purpose of this research is to identify soil zone affected by a plant root activity using electrical resistivity tomography (ERT) technique. Four plastic containers were prepared for two different soil textures (clay and sandy loam) and one container for each texture was selected for planting four corn seedlings (Zea mays L.) and the others were prepared for the blank. For ERT monitoring, we prepared 0.8 m plastic sticks with 17 electrodes installed with 5 cm space. The Ministing (AGI Inc., Texas) instrument for electrical resistivity measurement and semi-auto converter of electrode arrangement were set up for dipole-dipole array. During 2 months of the corns growing, ERT monitoring was made 3 to 4 days after the irrigation practice. Despite of the same amount water supplied into soils, two textures showed very different apparent resistivity values due to different clay content. The apparent electrical resistivity is consistently lower in clay loam comparing to sandy loam soil implying that plant root does not significantly alter the overall trend of resistivity. When plant root system, however, is active both soils with plants showed 2-7 times higher electrical resistivity and higher coefficient variation than soils without plant, implying the effect of root system on the resistivity, in which may caused by. This result suggests plant root activities regulating the soil water dynamics mainly control the variation of electrical resistivity over soil textural difference. Therefore the identification of water uptake zone would highly be correlated to plant root activities, thus ERT will be feasible approach to identify spatial characteristics of a plant root activity.

The Resistivity Survey of the Takaoi Area on Central Kalimantan, Indonesia (인도네시아 칼리만탄 타카오이(미고결 역질층)지역에서의 전기비저항 탐사)

  • Cho Jin-Dong;Park In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.110-114
    • /
    • 2001
  • In order to obtain the geological information of the shallow subsurface and the characteristics of resistivity curves to the lateral extent of the gold bearing gravel layer underlaid by a thick layer, electrical resistivity surveys had been carried out in the northern area of Takaoi village, Kalimantan, Indonesia from September 30th to October 27th in 1999. The Dipole-Dipole (Dp-Dp) resistivity survey was carried out with a electrode spacing of A=3m, 5m and electrode separation index n=10, and the vertical electrical sounding (VES) of the Schlumberger type was performed at 6 sites. The interpretation of the Dp-Dp data and VES curves by computer modeling indicates 5 classified layers as the horizontal structure. And the characteristics of VES curves shows us KH type.

  • PDF

Characterization of an Animal Carcass Disposal Site using Electrical Resistivity Survey (전기비저항 탐사를 이용한 가축사체 매몰지 특성 분석)

  • Ko, Jin-Suk;Kim, Bong-Ju;Choi, Nag-Choul;Kim, Song-Bae;Park, Jeong-Ann;Park, Cheon-Young
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.409-416
    • /
    • 2012
  • In this study, an electrical resistivity survey and a drilling investigation were conducted at an animal carcass disposal site. Chemical analysis of leachate collected from the site was also performed (sampling times: May 2011 and June 2012). Five lines of dipole-dipole electrical resistivity surveys were carried out, along with drilling investigations at 3 points within the disposal areas and 11 points near the disposal site. Two-dimensional inverse modeling of the collected resistivity data was performed to evaluate the properties (size, depth, and form) of the disposal site. Leachate analysis showed that pH of leachate decreased from 7.4 to 6.7, while Eh changed from -358 mV to -48 mV over time. In addition, dissolved ions increased due to the progression of carcass decomposition. Results of the electrical resistivity survey indicated that low resistivity zones (minimum value, $0.64{\Omega}m$) existed at a depth of 8 m from the surface. Considering the bedrock location and carcass disposal depth, there was no evidence of bedrock contamination by leachate. The results of the electrical resistivity survey are consistent with those of the drilling investigation, which indicates that electrical resistivity effectively depicted the properties of the disposal site. This study demonstrates that electrical resistivity survey is a suitable technique for investigation of animal carcass disposal sites.

Application of hydrogeological and geophysical methods to delineate leakage pathways in an earth fill dam (사력댐 누수경로 파악을 위한 수리지질과 지구물리 방법의 적용)

  • Song Sung-Ho;Song Yoonho;Kwon Byung-Doo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.92-96
    • /
    • 2005
  • Comprehensive field surveys, including various hydrogeological and geophysical methods, were carried out to appraise the applicability of those methods to a leakage problem at the Sandong earth fill dam in southwestern Korea. The methods applied in the fold site were tracer tests, monitoring of drawdown and leakage with discharge of reservoir water, electrical resistivity surveys using the dipole-dipole array, self-potential (SP), and temperature logging methods. The leakage pattern in the reservoir wall was demonstrated by hydrogeological methods and was further clarified by the geophysical surveys. Leakage turned out to be through the right abutment of the reservoir wall. In this study, we conformed that the electrical resistivity method is effective in detecting the zones favorable to leakage, and SP methods are useful for delineating the leakage pathways themselves, because leaks generate strong streaming-potential anomalies.

Proposed Survey Steps for Investigation of Land-Creeping Susceptibility Areas: A Focus on Geophysical Mapping of the Yongheung-dong, Pohang, Korea

  • Kim, Jeong-In;Lee, Sun-Joong;Kim, Kwan-Soo;Lee, Jae-Eun;Sa, Jin-Hyun;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.269-281
    • /
    • 2021
  • Land creeping is the imperceptibly slow, steady, downward movement o f slope-forming soil or rock. Because creep-related failures occur frequently on a large scale without notice, they can be hazardous to both property and human life. Korea Forest Service has operated the prevention and response system from land creeping which has been on the rise since 2018. We categorized and proposed three survey steps (e.g., preliminary, regional, detailed) for investigation of creeping susceptibility site with a focus on geophysical mapping of a selected test site, Yongheung-dong, Pohang, Korea. The combination of geophysical (dipole-dipole electrical resistivity tomography and reciprocal seismic refraction technique, well-logging), geotechnical studies (standard penetrating test, laboratory tests), field mapping (tension cracks, uplift, fault), and comprehensive interpretation of their results provided the reliable information of the subsurface structures including the failure surface. To further investigate the subsurface structure including the sliding zone, we performed high-resolution geophysical mapping in addition to the regional survey. High-resolution seismic velocity structures are employed for stability analysis because they provided more simplified layers of weathering rock, soft rock, and hard rock. Curved slip plane of the land creeping is effectively delineated with a shape of downslope sliding and upward pushing at the apex of high resistive bedrock in high-resolution electrical resistivity model with clay-mineral contents taken into account. Proposed survey steps and comprehensive interpretation schemes of the results from geological, geophysical, and geotechnical data should be effective for data sets collected in a similar environment to land-creeping susceptibility area.

Application of Electrical Resistivity Measurement to an Evaluation of Saline Soil in Cropping Field (염류집적 농경지에서 전기비저항 탐사기법의 활용성)

  • Yoon, Sung-Won;Park, Sam-Gyu;Chun, Hyen-Jung;Han, Keung-Hwa;Kang, Seong-Soo;Kim, Myung-Suk;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1035-1041
    • /
    • 2011
  • Salinity of soil under the plastic film houses in Korea is known as a significant factor to lower the crop production and to hamper the sustainable agricultural land management. In this study we propose a field monitoring technique to examine the methods applied to minimize the adverse effect of salts in soil based on the relationship between soil electrical characteristics and soil properties. Field experiments for 4 different treatments (water only, fertilizer only, DTPA only, and DTPA and fertilizer together) were conducted on soils at the plastic film house built for cultivating a cucumber plant located at Chunan-si, Chungchungnam-do in Korea. The electrical resistivity was measured by both a dipole-dipole and wenner multi-electrodes array method. After the electrical resistivity measurement we also measured the soil water content, temperature, and electrical conductivity on surface soil. The resulted image of the interpreted resistivity by the inversion technique presented a unique spatial distribution depending on the treatment, implying the effect of the different chemical components. It was also highly suspected that resistivity response changed with the nutrients level, suggesting that our proposed technique could be the effective tool for the monitoring soil water as well as nutrient during the cropping period. Especially, subsoils under DTPA treatment at 40 to 60 cm depth typically presented lower soil water accumulation comparing to subsoils under non-DTPA treatment. It is considered that DTPA resulted in increase of a root water uptake. However, our demonstrated results were mainly based on qualitative comparison. Further experiments need to be conducted to monitor temporal changes of electrical resistivity using time lapse analysis, providing that a plant root activity difference based on changes of soil water and nutrients level in time.

Feasibility of 3D Dipole-Dipole Electrical Resistivity Method to a Vein-Type Ore Deposit (국내 맥상광체조사를 위한 3차원 쌍극자-쌍극자 전기비저항 탐사의 적용성 분석)

  • Min, Dong-Joo;Jung, Hyun-Key;Lee, Hyo-Sun;Park, Sam-Gyu;Lee, Ho-Yong
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.268-277
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore deposit survey in literature. Geophysical surveys have been applied to the investigation of both metallic and non-metallic ore deposit. For metallic ore-deposit survey, the 2D electrical resistivity method has been popularly used, because metallic mineral deposits are generally more conductive than surrounding media. However, geological structures are 3D rather than 2D structures, which may lead to misinterpretation in 2D inversion section. In this study, 3D effects are examined for several 3D structures such as a width-varying dyke model and a wedge-shaped model. We also investigate the effects of the direction of survey line. Numerical results show that the width-varying dyke model yields some low resistivity zone in the deep part, which is independent of real ore-body location. For the wedge-shaped model, even though the survey line is located apart from the ore body, the 2D inversion section still shows low resistivity zone in the deep part. When the survey line is not perpendicular to the strike of the ore body, the low resistivity zone is slightly broader but shallower than that obtained along the survey line perpendicular to the strike. For the survey lines that have an angle smaller than $45^{\circ}$ with the strike of the ore body, the inversion results are totally distorted. From these results, we conclude that 2-D survey and interpretation can lead to misinterpretation of subsurface structures, which may be linked to economical loss. Eventually, we recommend to apply 3-D rather than 2-D electrical resistivity survey for ore-deposit survey.

Application of Resistivity Technique for Identifying Cavities Near Surface in Karst Area, Muan-gun, South of Korea (무안군 카르스트 지역의 지하공동 탐지를 위한 전기비저항 탐사 기술 적용)

  • Farooq, Muhammad;Park, Sam-Gyu;Song, Young-Soo;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.368-372
    • /
    • 2008
  • This study evaluates the usefulness and capability of surface electrical resistivity technique for identifying the weak zones or subsurface cavities in karst area with limestone formation. Weak zones or cavities near surface can be potentially dangerous and several problems are associated with collapse of roads or buildings accompanied by subsidence phenomena. In this paper, both two and three dimensional resistivity investigation were conducted to investigate subsidence along a road in Yongweol-ri, Muan-gun, South Korea. The results of the resistivity survey using dipole-dipole array provide a clear view of the weathered regolith, the distribution of weak zones or cavities and bedrock. Several low resistivity areas were identified and subsequent drilling led to the discovery of several weak zone or clay-filled underground cavities. The drilling results show excellent correlation with the resistivity images. It is illustrated, the ability of electrical technique to produce high resolution images of subsurface, which are useful for subsidence assessment. Also the results of this study have demonstrated that two and three dimensional electrical resistivity surveys are useful for delineating the subsidence area. Based on resistivity imaging, the map of hazardous zone has been developed.

Application of geophysical exploration for gold in the YongJang mine, Masan (마산 용장광산에서 금광에 대한 물리탐사의 적용)

  • Park, Jong-Oh;Song, Moo-Young;Park, Chung-Hwa;You, Young-June
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.213-219
    • /
    • 2006
  • The Yongjang mine is located in Masan City, Gyeongsangnamdo, which consists of a black shale possessing quartzite veins with othercompositions such as gold, silver, and sublimated sulfur. The average width of the veins is $9{\sim}17cm$ and the average degrees of the gold and silver are 3.6 g/t and 113.6 g/t respectively. A regional and a detailed scale electrical resistivity surveys are conducted to determine the existence of the mineralization zones and the linear structures in the study area. In addition, surveys of a several different array methods are conducted such as dipole-dipole array in the surface and borehole-to-surface array, surface-to-borehole array, and dipole-dipole array in the borehole. The method of element division can be applied to the region in which the borehole is curved, inclined or the distance between the electrodes is shorter than that of nodal points, because the coordinate of each electrode cannot be assigned directly to the nodal point if several electrodes are in an element. Yongjang vein is extended longer under the subsurface than on the surface in the images reconstructed from the 3D inversion. Therefore, it is recognized that the 3-D interpretation of the electrical resistivity survey is a very useful method to figure out the existence of strike and extension direction because the mineralization zones and the linear structures are shown in each depth.

  • PDF