• 제목/요약/키워드: electrical resistance method

검색결과 1,370건 처리시간 0.024초

Investigation on Contact Resistance of Amorphous Indium Gallium Zinc Oxide Thin Film Transistors with Various Electrodes by Transmission Line Method

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.139-141
    • /
    • 2015
  • Contact resistance of interface between the channel layers and various S/D electrodes was investigated by transmission line method. Different electrodes such as Ti/Au, a-IZO, and multilayer of a-IGZO/Ag/a-IGZO were compared in terms of contact resistance, using the transmission line model. The a-IGZO TFTs with a-IGZO/Ag/a-IGZO of S/D electrodes showed good performance and low contact resistance due to the homo-junction with channel layer.

회전자 저항 변동을 보상한 유도전동기의 센서리스 백터 제어 (Sensorless Vector Control of Induction Motor Compensating the variation of rotor resistance)

  • 박창훈;김광연;이택기;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.140-143
    • /
    • 1991
  • This paper describes a compensation method for the rotor resistance variation of induction machines in speed sensor-less vector control system using MRAS(model reference adaptive system). In case of rotor resistance variation, the analysis of the conventional speed sensor-less vector control system using MRAS is presented and the compensation method for rotor resistance variation using Fuzzy logic is proposed. In order to confirm the performance of the proposed algorithm, computer simulation is performed.

  • PDF

대체 보조전극을 이용한 접지저항 측정값 비교 (Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode)

  • 이상익;유재근;전정채;전현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

An Efficient On-line Identification Approach to Rotor Resistance of Induction Motors Without Rotational Transducers

  • Lee, Sang-Hoon;Yoo, Ho-Sun;Ha, In-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.86-93
    • /
    • 1998
  • In this paper, we propose an effective on-line identification method for rotor resistance, which is useful in making speed control of induction motors without rotational transducers robust with respect to the variation in rotor resistance. Our identification method for rotor resistance is based on the linearly perturbed equations of the closed-loop system for sensorless speed control about th operating point. Our identification method for rotor resistance uses only the information of stator currents and voltages. In can provide fairly good identification accuracy regardless of load conditions. Some experimental results are presented to demonstrate the practical use of our identification method. For our experimental work, we have built a sensorless control system, in which all algorithms are implemented on a DSP. Our experimental results confirm that our on-line identification method allows for high precision speed control of commercially available induction motors without rotational transducers.

  • PDF

Basic study on correction method of measured earthing resistance by 4-potential method

  • Saki, Ueta;Takehiko, Takahashi
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2008
  • The full of potential method is generally used for measuring the earthing-resistance. This method needs two auxiliary electrodes and it is required that two auxiliary electrodes are placed at enough distances from the earthing electrode, e.g. building foundation. However, in urban area there is not enough space for taking measurement. So, it is very difficult to measure the earth resistance precisely. However, there is the 4- potential method when it stand on the theory of the full of potential method. It is the purpose of this paper to basic study on correction method of measured earthing resistance by 4-potential method.

  • PDF

광원 적용을 위한 신재생에너지 카본 박막의 전기적 특성 (Electrical Properties of Renewable Energy Carbon Film for Light Source Technology)

  • 이상헌
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.558-560
    • /
    • 2005
  • The carbon film was deposited by the electrolysis of methanol solution. Carbon films have been grown on silicon substrates using the method of chemical process. From investigations of the Raman spectroscopy and the FTIR spectroscopy, the carbon film deposited by the electrolysis was identified the hydrogenated carbon film with the porous structure. The carbon film deposited by elctrolysis of methanol was identified as the hydrogenated carbon film with porous structure. Deposition parameters for the growth of the carbon films were current density, methanol liquid temperature. We electrical resistance and surface morphology of carbon films formed various conditions specified by deposition parameters. It was clarified that the high electrical resistance carbon films with smooth surface morphology are grown when a distance between the electrodes is relatively wider. We found that the electrical resistance in the films independent of both current density and methanol liquid temperature. The temperature dependence of the electrical resistance in the low resistance carbon films is different from one obtained in graphite..

측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정 (Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems)

  • 이복희;엄주홍;김성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

ERT를 이용한 2차원 대지모델 영상복원 (2D Image Reconstruction of Earth Model by Electrical Resistance Tomography)

  • 부창진;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3460-3467
    • /
    • 2013
  • 본 논문에서는 2차원 대지구조를 분석하기 위해 ERT(electrical resistance tomography) 방법을 사용하여 대지모델을 영상복원하는 방법들을 수치적인 실험방법들을 통해 비교분석한다. 영상복원을 위한 역산방법으로는 Gauss-Newton, TLS(truncated least squares), 그리고 SIRT(simultaneous iterative reconstruction technieque) 알고리즘들이 제시되고 대지저항을 측정하기 위한 전극법은 대표적인 웨너와 슐럼버거 측정방법을 사용한다. 컴퓨터 시뮬레이션을 통해 Gauss-Newton과 TLS 알고리즘이 대지모델의 2차원 영상복원에서 적합하다는 것을 보인다.

스위치의 선형영역을 이용한 무효전력보상기의 돌입전류 억제 방안 (Inrush Current Suppression Method of the Reactive Power Compensator by using a Linear Region of the Switch)

  • 박성미;강성현;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.55-64
    • /
    • 2013
  • In this paper, a new topology which can add a small reactor in series to a condenser-bank type reactive power compensator to limit current is proposed. And also the proposed topology can add or remove a power condenser safely without any addition of inrush-current suppression resistance. The proposed method tests variable resistance of the drain source of a switching device which is controlled by gate voltage in a two-way switch with a diode rectifier and FET switch. In other words, the proposed method is a inrush-current suppression method with the structure of variable resistance. In particular, the proposed method creates smooth current without any resonance in inrush-current as well as is not limited by the time of switch on and off.

동저항 특성을 이용한 저항 스폿 용접기의 정전력과 정전류의 혼합모드 제어 (Mixed Mode Control of Constant Power and Constant Current for Resistance Spot Welder using Dynamic Resistance Characteristics)

  • 강성관;정재헌;노의철
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1571-1577
    • /
    • 2015
  • A new mixed mode control of constant power and constant current for resistance spot welding inverter is proposed to improve the weld quality. The conventional control scheme adopts constant current or constant power control mode, however, it is not easy to guarantee the high weld quality because of the nonlinear resistance characteristics of the welding point. The proposed method utilizes the nonlinear characteristics by measuring the dynamic resistance in real time. Therefore, it is possible for the welder to be controlled adaptively depending on the welding state. Experimental results show that the proposed control scheme improves the weld quality by 6.8 times compared with the conventional constant current mode control.